Linkcom SlimDoorPhone 1 button User manual

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
1
Slim Door Phone
1,2 or 4 buttons
!
!
!
!
!
!
!
!
!
Manuel
V2.2
find the latest version of the manual and firmware at
www.linkcom.fr

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
2
Index
1.#Basic#description#..................................................................................................................#3!
1.1!Features................................................................................................................................................................................!3!
1.2!SlimDoorPhone!models!.................................................................................................................................................!3!
2!#Installation#........................................................................................................................#3!
2.1!Opening,!wiring,!wall!mounting!and!settings!......................................................................................................!3!
2.1.1!Name(card(panel(............................................................................................................................................................(3!
2.1.2!Uncover(control(elements(...........................................................................................................................................(4!
2.1.3!Wiring(and(wall(mounting(.........................................................................................................................................(4!
2.1.4!Switches(.............................................................................................................................................................................(5!
2.1.5!Voice(level(..........................................................................................................................................................................(5!
2.2!Location!of!ID!Doorphone!components!.................................................................................................................!6!
2.3!!Changing!name!cards!....................................................................................................................................................!7!
2.4!Final!closing!of!ID!Doorphone!....................................................................................................................................!7!
2.4.1!Covering(control(elements(.........................................................................................................................................(7!
2.4.2!Replacing(name(card(panel(.......................................................................................................................................(7!
3!SlimDoorPhone#Services#.....................................................................................................#8!
3.1!Signalling!Overview!........................................................................................................................................................!8!
3.2!Visitor!at!the!door!............................................................................................................................................................!8!
3.3!Telephone!Caller!..............................................................................................................................................................!8!
3.3.1!Outgoing(call(....................................................................................................................................................................(9!
3.3.2!Incoming(call(...................................................................................................................................................................(9!
4!Parameter#programming#....................................................................................................#9!
4.1!Programming!from!a!telephone!by!DTMF!............................................................................................................!9!
4.1.1!Entering(programming(mode(..................................................................................................................................(9!
4.1.2!Parameter(programming(...........................................................................................................................................(9!
4.2!Programming!from!a!PC!–!ID!Manager!program!..............................................................................................!10!
5!Parameter#description#.......................................................................................................#10!
5.1!Direct!Dialling!–!Memories!........................................................................................................................................!10!
5.2!Relay!....................................................................................................................................................................................!11!
5.3!Basic!parameters!............................................................................................................................................................!12!
5.4!Time!parameters!............................................................................................................................................................!13!
5.5!Presetting!and!Deleting!...............................................................................................................................................!15!
5.6!Exit!programming!..........................................................................................................................................................!16!
5.7!System!setting!.................................................................................................................................................................!16!
5.8!Overview!of!Parameters!.............................................................................................................................................!16!
6!Technical#parameters#........................................................................................................#18!
6.1!Electrical!parameters!...................................................................................................................................................!18!
6.2!Mechanical!dimensions!...............................................................................................................................................!19!
7!Table#for#easy#programming#..............................................................................................#19!
8!Drilling#master#board#.........................................................................................................#21!

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
3
1. Basic description
1.1Features
!Very slim module for surface mounting only. Supplied in 1, 2 or 4 button variants.
!Voice communication powered from analogue telephone line only.
!Pulse and tone (DTMF) dial
!Two 16 digits numbers saved under each button (includes *, #, RECALL and pause)
!DAY/NIGHT mode
!Call prolongation by dialling * or #
!Electrical (magnetic) lock compatible
!Code to hang up from phone
!Code to open the door by phone
!3 different passwords for code lock (external code from buttons)
!Optional number of rings before picking up incoming call
!Optional time between code entry button-presses
!Optional delay time before redialling
!Optional time before dialling starts
!Optional parameters for DTMF tones, Recall and Pause duration
!3 default levels
!Programming by remote control (DTMF) and by direct PC connection via USB cable (available
separately)
!Integrated heating of printed circuit (PCB) (option)
!Permanent lighting through visiting cards (option)
!Earthing outlet for better protection against static electricity
!Switchable audible confirmation tones
1.2SlimDoorPhone models
Three versions are available :
1 button 2 buttons 4 buttons
2Installation
This compact unit is fixed by 2 screws to the wall.
2.1 Opening, wiring, wall mounting and
settings
2.1.1 Name card panel
1.Every unit is supplied with a special key which is used to
release the name cards on the front panel. Push the key
into the hole in the speaker grille
(see figure - 1).
2.Push the name card panel down and then push it towards
to grille (see figure-2).
3.The panel will be released. Pull it towards you to remove
(see figure – 3).

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
4
2.1.2 Uncover control elements
4.Push the aluminium speaker grille down (see figure – 4).
2.1.3 Wiring and wall mounting
5. Use the wall mounting template at the end of the manual
to mark the position for the screw holes and cable
connection on the mounting surface. Drill the holes.
6. Feed the cable (analogue line, power supply, lock – see
figure - 6) through the cable hole.
Fix the panel to the wall using the screws and rawlplugs
supplied.
Note: Some materials such as metal and wood may
require special screw types.
To power the unit for voice, connect the telephone
wires into the terminal (on the right side). Using
either a standard analogue phone line or an
analogue extension on a PBX.
For the external power supply, connect to the terminal "12V" external power supply AC
min. 10V / max. 15V or DC min. 12V / max. 18V.
The energy consumption of a connected electrical (magnetic) lock (0,5A – 1,0A)
determines the load on the power supply. If you activate the heating feature the PCB
current will climb to about 150mA. We recommend power supply AC 12V/1A.
The wiring of relay contacts is explained in the next picture. The symbol "NO" means
contact normally open, "COM" means sharing output
(central) and "NC" means contact normally closed. The relay contact is isolated from the
other circuits on the board. For the variants of lock connection see the picture below.
Power
supply
lock
Telephon
e line

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
5
Wiring of standard and magnetic (inverse) lock
6. A special USB cable enables the doorphone to be connected to a PC for programming of
individual parameters. A dedicated Windows program is included on the CD (requires version
W98SE or higher).
2.1.4 Switches
7.The switch number 1 (see figure – 8) activates heating
of the PCB. This is for increased resistance against
humidity. To use this feature you must connect an external
12V power supply.
8.The switch number 2 (see figure – 9) is required for
programming the unit when the password is forgotten. It is
performed by ordinary phone (DTMF – tone dial ).
The switch is
The PCB heating has two major benefits. Firstly, it warms the board during winter
time (temperatures under -20 C, most circuits have warranty operation down to -20 C)
and secondly it helps to protect the PCB against humidity when installed outside.
2.1.5 Voice level
9. Voice communication – the trimmer position is factory and should be suitable for
most installations. Change the trimmer position only when necessary.
The trimmer "MIC" is designed for microphone
volume setting. The trimmer "SPK" is designed for
loudspeaker volume setting.
The volume settings are more than adequate for
most situations. Therefore we do not recommend
setting the trimmer position more than ½. The most
suitable position is 1/3 from minimum amplification.
The trimmer "TRH" is designed for setting the
microphone activation level. It allows balancing
between the microphone and speaker to eliminate
feedback. This setting is also influenced by the noise
of the surrounding environment.
Set up Process: The trimmers MIC and SPK are
set to ¼position from minimum loudness level (turn
fully anti-clockwise for minimum). The trimmer TRH
is set to a central position. To fine tune, make a test call. Speak quietly, and by adjusting
the trimmer TRH from the central position anticlockwise, your speech should be heard more
clearly by the PBX user. The amplification of the speaker can be adjusted according to your
requirements. Voice interruption might occur if you set the amplification too high. In this
case you can use the trimmer TRH to correct the balance between the speaker and the
microphone.

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
6
2.2Location of ID Doorphone components
All mounting, control and setting elements are located under the speaker front aluminium grille.
.
.
PC
connector
SlimDoorPhon
e fixing screw
hole
Service
switch
Loudspeaker
MIC-
setting of
microphon
e volume
TRH –
setting of
micropho
ne
activation
SPK- setting
of speaker
volume
Heating
activatio
n
12V =/~ for
relay, light
and heating
Relay
Telephone
line
connection
Microphon
e
Buttons
Hole for lead in
cable

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
7
2.3 Changing name cards
Name card panel (2on page 3) has spaces
to insert printed name cards. Insert name cards
from top (see picture). Cards can easily be printed
with pictures as well as text using the included
software. The card outline is marked for easy cutting .
2.4Final closing of ID Doorphone
2.4.1 Covering control elements
1.Push aluminium speaker cover back up (see picture). Take
care when re-covering the speaker. The aluminium edge of
the speaker may be gently pressed if required.
2.4.2 Replacing name card panel
2.Push key into hole in speaker grille as far as possible.
(see figure -2).
3.Push name card panel upwards and push the bottom
edge in (see figure - 3).
4.Push the name card panel back down behind the lip of
the casing (see figure - 4).
pocket
Panel
with
cards

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
8
3SlimDoorPhone Services
3.1Signalling Overview
The unit signals acoustic conditions that may occur during operation. You can listen to
the signalling samples in the ID Manager program.
Condition
Tones
Tone
frequency
Pick up line
––––
425-850-1275
Hang up line
–––
1275-850-425
Confirm command
––––
425
Dialling
DTMF/Pulse
Call
Conversation end warning
––––
1275
Enter programming (phone or
PC)
––––
850
Programming tone
––––––––
mod. 850
Parameter confirmation
––––
Programming from PC
Silent
Connection to line (Reset)
––––
1275-850-1275
Error
–––––
––
425….
Empty memory
–––––
––
850-1275-
1700…
Open lock
modul 50/1250
3.2Visitor at the door
When a visitor presses a button the unit will lift up the line, either immediately
(providing the button is not the first number from code lock), or with delay (parameter 53)
and after period given by parameter 55, will dial the programmed phone number. The dialled
number is dictated by the chosen mode, which is set in the unit (parameter 47):
- Day/night mode = If the unit is in Day mode, it will always dial the number set in
parameter 1, In Night mode, it will always dial the number set in parameter 2. The
mode switchover is set in parameters 45,46.
- Two-Group mode = on the first press the number set in parameter 1 will be dialled.
By pressing of the same button twice, or on detection of busy tone after trying the
first number, the unit will select the number from the second group (parameter 2).
The next press of the same button again selects the number from the first group,
etc..……
If the button is pressed after the line has been opened (but before the call is
answered), the unit will hang up for the period given by parameter 54, lift up the line and
dial the other group number.
The relay can be controlled by pressing the buttons in the combination that is set in the
preprogrammed code (parameters 32-34). The time between presses must not be bigger
than that set in parameter 53. The unit will lift up and close the corresponding relay or the
period given by parameter 36 . Then it will hang up.
3.3Telephone Caller
A Telephone Caller is a person that is in phone connection with SlimDoorPhone.

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
9
3.3.1 Outgoing call
An “outgoing” call is a call from the unit (i.e. when a visitor presses a button). Once the
visitor has pressed a button a telephone will ring. On answering the telephone, you will be
able to converse with the visitor. 10 seconds before the maximum call duration (parameter
52) the unit will emit a tone to warn that the call will end. The call may be extended by
pressing the key as set in parameter 42. A code may be dialled to close the relay (parameter
35), releasing the lock. Hanging up the telephone will end the call, as will the busy tone from
the PBX.
3.3.2 Incoming call
An incoming call is a call to the unit. After dialling the PBX extension number to which the
unit is connected, the unit will ring for the set number of rings (parameter 51), the unit will
lift up and it is possible to speak. The possibilities are the same as with outgoing call
(Chapter 3.3.1). It is also possible to switch between Day and Night service.
•If, within the first 10 seconds, the service password is entered, the unit will switch to
programming mode and voice communication will cease.
•During an incoming call it is possible to restrict relay control (parameter 37). This can
be useful in some special applications.
4Parameter programming
4.1Programming from a telephone by DTMF
4.1.1 Entering programming mode
The SlimDoorPhone may be set to programming mode in two ways:
1. by password – dial the unit‘s number (either extension number, if connected to a PBX or
telephone number, if connected to a PSTN line). The unit will answer (you will hear the
Pick up line tone – see Chapter 3.1 page8). Within 10 seconds dial #xxxx, where
xxxx is the password for entry to programming and, if OK, the registration tone for
programming mode will sound, and afterwards the Programming tone is heard (see
Chapter 3.1 page 8).
2. by "SERVICE" switch – dial the unit in the same way as in 1, but when the SERVICE
switch is connected, the unit will automatically enter programming mode. You will
hear the call connection confirmation tone, the confirmation tone for programming
mode and afterwards the Programming tone is heard. (see Chapter 3.1 page 8).
4.1.2 Parameter programming
The initial state for programming is signalled by the programming confirmation tone.
The unit will always revert to this state after 5 seconds of inactivity, even if you have started
to program a parameter.
When programming, there are two types of parameters. The majority are parameters
with a fixed length. The parameter is always saved immediately and is confirmed by
Parameter Confirmation tone. Parameters with variable length (parameters 1,2,32,33,34)
are saved after the inactivity period expires (5 sec). However, a varaible length parameter
will be saved immediately when maximum permitted number of digits is reached. For
parameters 1 and 2 the maximum number of digits is 16, and for parameters 32,33,34 it is
6.
If, during programming, you enter a number which is not allowable, then the unit
immediately emits an error tone. The parameter will not be recorded or changed, and the
unit will return to its initial programming state and it will be possible to repeat the parameter
setting or program another parameter.
The unit stays inactive in programming mode for 34 seconds and will then automatically
hang up. Every time a DTMF tone is dialled, this period is reset. Alternatively, parameter 9
may also be selected to end programming mode.

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
10
To program a parameter, enter the parameter number followed by the value you wish to
set. The unit will either respond with the Parameter Confirmation Tone, or one of the Error
Tones.
Note 1. if you wish to maintain the connection in programming mode (i.e. extend the 34 seconds
period) then it is necessary to occasionally press a key (e.g. *, # or 7). The unit will respond with an
error tone but the connection will be kept alive.
Note 2. The # sign is not used in the values for parameters 32,33 and 34, and can be used to
immediately save the parameter.
Note 3. If you hang up the phone during programming mode without press 9, the doorphone will stay
in programming mode during 20 seconds.
4.2Programming from a PC – ID Manager program
To setup the unit from a PC you will require a special USB tool cable, available separately,
and must first install the USB driver and ID Manager software. Refer to the CD for more
details. The unit must also be connected to the telephone line.
Procedure:
- Connect the ID Doorphone to the line
- Connect the unit to the PC with the USB tool cable.
- Run the ID Manager program. The unit will enter PC programming mode and emit the
Enter Programming tone (see chapter 3.1). If connection is lost, it is necessary to
disconnect the USB cable from unit and connect it again. The unit will answer and,
providing the ID Manager program is running, it will confirm its entry into programming
mode again.
Refer to the ID Manager manual for more details.
5Parameter description
5.1Direct Dialling – Memories
Parameter
Value
Description
Default
Exam.1
Exam.2
1
t nn…
No. nn under
button t
-
-
-
USB – PC
connection
USB – tool
Small
connector

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
11
t– Button number (memory) [1-4]
nn – telephone number up to 16 digits to be stored. Refer to the table
for other choices.
The number stored in parameter 1 is the number for the first group or
the number for Day mode.
Parameter
Value
Description
Default
Exam.1
Exam.2
2
t nn…
No. nn under
button t
-
-
-
t– Button number (memory) [1-4]
nn – telephone number up to 16 digits to be stored. Refer to the table
for other choices.
The number stored in parameter 2 is the number for the second group
or the number for Night mode
Note: The switchover to Day/Night mode remains set in the unit even after
line disconnection.
5.2Relay
Paramet
er
Value
Description
Defaul
t
Exam.
1
Exam.2
31
r m
Relay mode
1
1
2
m– relay mode [ 1-2]
m=1 relay mode – relay will close on command or password for ss period (used for
electrical locks, gate opening, etc.)
m=2 button mode – (activated by button press e.g. external bell).
Paramet
er
Value
Description
Defaul
t
Exam.
1
Exam.
2
32
r
hhhhhh
External access code in
DAY + NIGHT mode
-
1212
1324
33
r
hhhhhh
External access code in
DAY mode
-
2211
2211
34
r
hhhhhh
External access code in
NIGHT mode
-
1122
1122
hhhhhh – password for relay closing from buttons [2 to 6 digits]
The 3 passwords are controlled by Day/Night; the combination is entered using the unit
buttons. It is influenced by the setting of Relay mode and Day/Night switchover. When set
to 2-group mode the unit is permanently in DAY mode.
Follow these rules when choosing password combination:
"Select passwords carefully, to prevent their discovery from wear on buttons caused by
frequent use.
"Select the first password button from infrequently-used buttons for direct dialling (-
extends choice time)(-not valid for keyboard).
parameter
dial
0 - 9
0 - 9
#
#
∗
∗∗
Recall
∗#
Pause
∗0
parameter
choice
0 - 9
0 - 9
#
#
∗
∗∗
Recall
∗#
Pause
∗0

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
12
Note: The switchover to Day/Night mode remains set in unit even after line disconnection.
Paramet
er
Valu
e
Description
Defaul
t
Exam.
1
Exam.
2
35
aa
Internal access code
55
55
55
aa – command from phone to relay closing [2 digits]
It is recommended to set the same command for Internal Access Code and End Call
(parameter 43) aa=bb.
Paramet
r
Value
Description
Default
Exam.
1
Exam.
2
36
ss
Relay closing time
05
02
05
ss – duration of relay closing [2 digits 01-99]
5.3Basic parameters
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
41
v
Dialling type
0
0
0
v – dial type
v=0 is DTMF tone dial, v=1 is pulse dial
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
42
z
Prolong call
∗
∗
∗
z – button for call prolongation ∗or # (10 sec before Maximum Call Duration the unit will
emit a tone. Pressing this button will prolong the call)
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
43
bb
End call
55
55
55
bb – command for unit hanging up from phone [2 digits]
It is recommended to set the same command for both Internal Access Code (parameter 35)
and End Call aa=bb.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
44
xxxx
Password
0000
0000
0000
xxxx – service password for entry to programming
Paramet
er
Valu
e
Description
Default
Exam.
1
Exam.
2
45
dd
DAY MODE switching
11
11
11
46
nn
NIGHT MODE switching
10
10
10

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
13
dd – command for DAY MODE switching [2 digits]
nn – command for NIGHT MODE switching [2 digits]
Note: The switchover to Day/Night mode remains set in unit even after line disconnection.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
47
e
Dialling mode
1
1
0
e – operating mode of unit
e=0 selects 2-Group mode, e=1 selects Day/Night mode.
5.4Time parameters
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
51
q
Number of rings before
pick-up
2
1
2
q – Number of incoming call rings before a call is picked up. The number can be set from 1
to 9.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
52
d
Maximum call duration
2
1
4
d – maximum time in minutes for which a call may last. This time can be
extended during a call by dialling Prolong Call digit from telephone
(∗or #). Time setting is per table.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
53
w
time between button
presses
2
2
2
w – max. time [sec] between button presses [range 1-9]
- relay closing – if time between two next presses is bigger than w time, the code
is not evaluated correctly.
- dialling – if the button pressed is the first password number for switch closing, so
the choice is delayed by this w time.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
54
z
On hook time before
new call
2
2
2
z – time [sec] for which the unit will hang up, before repeat dialling (button pressing during
call or dialling, busy tone detection) [range 1-5]
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
55
z
Call start time
1
1
1
time
[min]
choice
0,5
0
1 - 9
1 - 9
15
∗
30
#

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
14
z – time [sec] after unit goes on hook before dialling [range 1-5]. This time is different for
each PBX, but most PBXs usually manage to process dialling up to 2 seconds after line
on hook.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
56
h
Number of rings before
hanging up or group
mode switching
12
12
12
h – specifies the amount of time spent ringing before the unit hangs up and tries the next
number.
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
57
t
DTMF tone duration
(ms)
5
(100ms)
5
(100m
s)
5
(100m
s)
58
m
Space duration between
DTMF tones (ms)
5
(100ms)
5
(100m
s)
5
(100m
s)
59
f
Recall duration (ms)
1
(100ms)
1
(100m
s)
1
(100m
s)
50
p
Pause duration (ms)
8
(800ms)
8
(800m
s)
8
(800m
s)
t – DTMF tone duration is determined by the formula:
(entered number + 5) x 10 = tone duration [ms]
[range 1-0 i.e. 60-150ms]
m – Space duration between DTMF tones is determined by the formula:
(entered number + 5) x 10 = gap duration [ms]
[range 1-0 i.e. 60-150ms]
f – Recall duration is determined by the formula:
entered number x 100 = Recall duration [ms]
[range 1-6 i.e. 100-600ms]
p – Pause duration is determined by the formula:
entered number x 100 = pause duration [ms]
[range 5-0 i.e. 500-1000ms]
– ptime is simultaneously the duration of interdigit gap at pulse dialling.
Paramet
er
Value
Description
Default
5*1
x
Number of busy tones before hahg
up
6
x – is number of busy tones before hahg up by next table:
x
number of busy tones
x
number of busy tones
1
4
5
8
2
4
6
8
3
6
7
10
4
6
8
10

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
15
Paramet
er
Value
Description
Default
5*2
y
Frequency of tone detection
4
y – setting range frequency of tone detection from telephone line, value is in next table:
y
frequency range
y
frequency range
1
200-350Hz
7
500-650Hz
2
250-400Hz
8
550-700Hz
3
300-450Hz
9
600-750Hz
4
350-500Hz
0
650-800Hz
5
400-550Hz
*
700-850Hz
6
450-600Hz
#
750-900Hz
Paramet
er
Value
Description
Default
5*3
z
Time of continuous tone before hang
up
0
z – time of continuous tone before hang up. Hang up on dial tone, setting the time by next
table:
z
time of continous tone
z
time of continous tone
1
1,2sec
7
3,3sec
2
1,6sec
8
3,6sec
3
2,0sec
9
3,9sec
4
2,3sec
0
4,2sec
5
2,6sec
*
4,6sec
6
3,0sec
#
5,0sec
5.5Presetting and Deleting
Paramet
er
Value
Description
Default
Exam.1
Exam.2
8#
#
Default setting
executes
8#
1
Setting per exam.
1
executes
8#
2
Setting per exam.
2
executes
This setting does not influence 1and 2(numbers stored in memory)
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
81
Deletes all numbers in
group 1 (Day mode)
82
Deletes all numbers in
group 2 (Night mode)
83
Default setting only
for parameters 3x
only 3..
84
Default setting only
for parameters 4x
only 4..
85
Default setting only
for parameters 5x
only 5..
The parameters 81 and 82 will delete all numbers stored in memories for buttons.
The parameters 83 – 85 will execute a selective basic setting only for parameters starting
with 3.. – 5..

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
16
ATTENTION !!! the deletion is non-reversible!!! Numbers must be programmed again.
5.6Exit programming
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
9
E N D
After dialling 9the unit will hang up. If you hang up the phone during programming mode without
press 9, the doorphone will stay in programming mode during 20 seconds.
5.7System setting
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
6#
s
Number of fitted buttons
of basic module
The basic module is fitted with 4 buttons as standard, i.e. s = 1 is set up for basic module
with one button and s = 2 for module with 2 buttons. This setting is a factory one, no service
can change it and so it is recommended not to change this parameter.
Note: Connecting to the line the value of this parameter is checked and if not satisfactory for unknown
reasons, so it is set up to s = 4 (fitted with 4 buttons).
ATTENTION !!! This parameter can cause the unit to function incorrectly.
Paramet
r
Value
Description
Default
Exam.
1
Exam.
2
6
z
Acoustic signalling
3 and 9
3 and
9
3 and
9
In default the unit produces acoustic signals. It can occasionally cause a problem of incorrect
detection of tones by PBX. By changing parameter „z“ you can switch off this acoustic
signalization. The values are:
z=0 – all signalling is switched off
z=1 – pick up and hang up tones are active only
z=2 – other tones active only (except pick up and hang up)
z=3 – all tones are active – (default)
It is possible to generate an audible signal (only in mode m=1) to alert visitors that the door
is unlocked so that they can enter. This is especially useful when using a DC power source,
as lock release may be silent.
z=8 – signalling is active
z=9 – signalling is unactive
Paramet
er
Value
Description
Default
Exam.
1
Exam.
2
6∗
t
Delay of line connection
(Siemens PBX)
1
1
1
Setes a delay for line pick-up (OFF HOOK) for new PBX types (particularly Siemens):
t=1 – standard operation
t=0 – delayed start
5.8Overview of Parameters
Parameter
Value
Description
Default
Exam.1
Exam.2
1
t nn…
No. nn under
button t
-
-
-

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
17
2
t nn…
No. nn under
button t
-
-
-
31
r
Relay mode
1
1
2
32
hhhhhh
External access
code in
DAY + NIGHT
mode
-
2211
1324
33
hhhhhh
External access
code in
DAY mode
-
2211
2211
34
hhhhhh
External access
code in
NIGHT mode
-
1122
1122
35
aa
Internal access
code
55
55
55
36
r ss
Relay closing time
05
02
05
41
v
Dialling type
0
0
0
42
z
Proling call
*
*
*
43
bb
End call
55
55
55
44
xxxx
Password
0000
0000
0000
45
dd
DAY MODE
switching
11
11
11
46
nn
NIGHT MODE
switching
10
10
10
47
e
Dialling mode
1
1
0
51
q
Number of rings
before pick-up
2
1
2
52
d
Maximum call
duration
2
1
4
53
w
Time between
button presses
2
2
2
54
z
On hook time
before new call
2
2
2
55
z
Call start time
1
1
1
56
h
Number of rings
before hanging up
or group mode
switching
12
12
12
57
t
DTMF tone
duration (ms)
5
(100ms)
5
(100ms)
5
(100ms)
58
m
Space duration
between DTMF
tones (ms)
5
(100ms)
5
(100ms)
5
(100ms)
59
f
Recall duration
(ms)
1
(100ms)
1
(100ms)
1
(100ms)
50
p
Pause duration
(ms)
8
(800ms)
8
(800ms)
8
(800ms)
6#
s
Number of fitted
buttons on basic
module
6*
t
Delay of line
connection
(Siemens PBX)
1
1
1
6
z
Acoustic signalling
3 and 9
3 and 9
3 and 9
8#
#
Default setting
executes

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
18
8#
1
Setting per exam.
1
executes
8#
2
Setting per exam.
2
executes
81
Deletes all
numbers in
group 1 (Day
mode)
82
Deletes all
numbers in
group 2 (Night
mode)
83
Default setting
only
for parameters 3x
only 3..
84
Default setting
only
for parameters 4x
only 4..
85
Default setting
only
for parameters 5x
only 5..
9
E N D
6Technical parameters
6.1Electrical parameters
Parameter
Value
Conditions
Minimum line current
18mA
line answered
Minimum line voltage
18V
line hang up
Voltage on line while off
hook (VA characteristics)
< 8V
< 12V
I = 20mA
I = 60 mA
Leakage in hang up status
< 50uA
U = 60V
Impedance of line
termination
130R +
820R paral. 220n
line answered
Bandwidth
300Hz – 3400 Hz
20 - 60mA
Impedance of ringing
> 2Kohm
25 – 60 Hz
Sensitivity of ringing
detector
min. 10 – 25 V
Pulse choice
40 / 60 ms
Tone choice level
4 - 6 dB
20 – 60 mA
Tone choice sensitivity
40 dB
20 – 60 mA
Sensitivity of tone detector
30 dB
20 – 60 mA
Power supply of lighting
through, switches and
heating
12V ± 2V , 10-12V ± 2V
Max. consumption of lighting
through and heating
300mA
12V
Max. voltage of switch
contact
48V
at I < 1A
Max. current of switch
contact
2A
at U < 30 V
Operational temperature
- 20 to + 50°C

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
19
6.2Mechanical dimensions
Dimensions WxHxD 104mm x 153mm x 16mm
Weight 360g
Unit material elox aluminium profile
Name card panel material acrylglas (plexiglass)
7Table for easy programming
Complete the values you want to program in the empty part of table on the next page. All
programming commands are located in the double-framed area, to simplify programming.
Retain a copy for future reference.
Use
Programming sequence
digits
Description
Detail
par.
Fill values
Number under button 1
Day/Gr.1
101
16
Number under button 2
Day/Gr.1
102
16
Number under button 3
Day/Gr.1
103
16
Number under button 4
Day/Gr.1
104
16
Number under button 1
Night/Gr.2
201
16
Number under button 2
Night/Gr.2
202
16
Number under button 3
Night/Gr.2
203
16
Number under button 4
Night/Gr.2
204
16
Relay mode
m=1 - 2
31
1
External access code
Day+Night
32
6
External access code
Day
33
6
External access code
Night
34
6
Internal access code
35
2
Relay closing time
[sec]
36
2
Dialling type
1 / 0
41
1
Prolong call
∗/ #
42
1
End call
43
2
Password
44
4
DAY MODE switching
45
2
NIGHT MODE switching
46
2
Dialling mode
1 / 0
47
1
No. of rings before pick-
up
51
1
Maximum call duration
[min]
52
1
Time between button
press
[sec]
53
1
On hook time before new
call
[sec]
54
1
Call start time
[sec]
55
1
Number of rings before
hang up or group mode
switching
56
2
DTMF tone duration
(n+5)x10
57
ms
1

Linkcom France
11 rue du Soleil Levant 92140 CLAMART Copyright © 2012 – Linkcom – Tous droits réservés
20
Gap between DTMF
tones
(n+5)x10
58
ms
1
Recall duration
nx100
59
ms
1
Pause duration
nx100
50
ms
1
This manual suits for next models
2
Table of contents
Other Linkcom Intercom System manuals