Listec SCU 800 User manual

This manual suits for next models

2

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SCU 800
d-LIST Control Unit
The sensor control unit SCU 800 is the central
supervisory element for the d-LIST-system. It provides
up to two d-LIST sensor cables with power performs
the cyclic addressing of the connected sensors every
10 seconds acquires the temperature values
measured by each sensor and evaluates the data with
reference to various criteria.
A fire alarm is generated if either a given maximum
threshold is exceeded or if an increase in temperature
takes place within a certain time (differential
evaluation). The two thresholds (set-points) can be set
individually for each of the attached sensor cables.
The measurement resolution of 0 1° gives the system a high sensitivity. The tried and tested algorithms used in
the evaluation eliminate false alarms due to natural temperature variations.
Alarms are indicated by LEDs on the front-panel and via floating contacts to a fire terminal station (fire control
panel) host computers or other transmission systems. Hereby alarms generated by the two sensor cables are
signalled individually.
Resetting takes place via an external signal from the fire terminal station or by pressing the front-panel mounted
reset button.
The serial RS-232 interface can be used for programming and setting of system parameters. LISTEC® GmbH
offers the terminal software LISTterm 8 for this purpose.
For the visualisation of the system status message- and temperature-lists as well as a graphic display of the
temperature and alarm data LISTgraph II and the Data Management Unit DMU 600 is available.
A LIST®controller can be used to connect and control several SCU 800 from a central point via a RS-485
interface.
1/2 60V041-06/ 02.12.13
General:
Collective display (LED's) or
Fire cable A
Fire cable B
Fault
Operation
Temperature measurement
Data transmission
Alarm criteria
Alarming due to the exceeding of an absolute- or a
differential-threshold (set-point). All thresholds are
individually settable for each sensor cable.
For both alarm criteria a pre-alarm can be set in the
range between 10 to 90% of the alarm thresholds.
Fault recognition
Sensor cable faults such as the malfunctioning of a
sensor or a cable break are recognised and
indicated within one measuring cycle generally
within 10 seconds. Faults in the control unit are
registered in the internal message list and are
signalled immediately.
Inter ace
RS-232 Serial-interface for programming
parameters and interrogation of system data.
Optionally a RS-485 interface.
Connections
All connections take place inside the unit via
terminals.
The RS-232 interface 9 pin D-Sub female is
accessible once the unit is opened.
System speci ications:
Number o measuring points
Max. 99 sensors per cable connection
Sensor cable length
Max. overall length of the sensor cable including
connection cables is 250 m.
The sensor cable may consist of separate cable
pieces
Delivery extent:
CD with data sheet operation manual description
of commands and system messages installation
guidelines
Serie 800
SCU800/3 Item number: G00231 SCU800/16 Item number: G00233
Continuous operating temperature: -10°C .. +60°C
Dimensions: 260 x 150 x 90 mm
Power supply: 21 – 29 VDC
Housing material: aluminium
Power consumption: 21 – 29 VDC
Weight: 1 9 kg Weight: 2 3 kg
Power consumption: (normal use) 1 9 W Power consumption: (normal use) 2 7 W
Outputs:
Floating change-over contacts with space for user defined supervisory
resistors:
Fire alarm 2 relays (1 per cable)
Fault alarm 1 relay (fail safe)
Outputs:
Floating change-over contacts with space for user defined supervisory
resistors:
Fire alarm 16 zonal relays
Fault alarm 1 relay (fail safe)
Switching voltage: 48 VDC / 32 VAC max.
Switching current: 250 mA max. (ohmsche Last)
Input: 5 VDC reset input galvanically isolated
2/2 60V041-06/ 02.12.13