Step 8 - If luminaire is furnished with photocontrol receptacle, install
the photocontrol or shorting cap.
Fig.9
L
L
G
Step 5 - Connect the green conductor to the chassis ground
(shown to the right of the terminal block).
G
Fig. 5
PKGINS-EC001
V6-051413
Information provided subject to change without notice.
Leotek Electronics USA Corp. | 726 South Hillview Drive | Milpitas, CA 95035 | 408.380.1788 | www.leotek.com
J
Fig. 8
K
Step 7 - Close the housing cover and fasten the two stainless
steel latches (inset) .
J
K
Fig. 7
Step 6 - Connect the input line conductors to the input terminal
marked “L” & “N”.
Note: Same connection for 120/240/270Vac Input Line.
When using 480Vac, “HV” series product the input connection is to
terminal “L” & “N”
Fig. 4-a Fig. 4-b
Step 4 - Adjust Drive Current
Drive current should be set to comport with designed
illumination levels and circuit loading. Consult with design
engineer before changing. Unless ordered otherwise, the
default factory setting is 700mA (blue wire). To change the
setting to 530mA (yellow wire), open the fast connector
shown in Fig 4-b, and change the connection accordingly.
Note: If the FDC option was ordered, the drive current can
not be changed.
EC Series Installation Guide –Page 3 of 3