Liton LCALDJ2 User manual

CATALOG # : SAVE THESE INSTRUCTIONS
L I G H T I N G
INSTALLATION INSTRUCTIONS
Page 1 of 5
01182019
LCALDJ2 SURFACE (CEILING MOUNT)
5461 W. Jefferson Blvd. Los Angeles, CA 90016 • P. 800-515-4880 • F. 800-972-4880 • www.liton.com Product specifications subject to change without notice.
FIG. 1
Keep these instructions in a safe place for future use/reference.
Important: Please read and understand all instructions
completely before installing this fixture.
WARNING: Fixture installation (and use) and all electrical connections must be in accordance with
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician
install this fixture for you. Fixture should be installed by a qualified electrician.
WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury.
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to
prevent electrical shock.
This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.
WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.
WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture,
Liton's web site or other installations). Also for use with covered ceiling mount.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter (GFCI).
WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain,
or similar combustible material.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter
(GFCI).
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.
Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED
fixture(s)/LED driver(s) on a single circuit.
Do not use any other electrical equipment (example: surge protector photocell, etc.) that
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED
fixture(s)/LED driver(s).
Install remote surge protector(s) (by others, goes on the circuit with nothing between the
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already
installed with a surge protector, to help remove power surges that may harm LED
fixture(s), appropriate for the installation. Periodically check and make sure that your
remote surge protector(s) are in good working order.
FIXTURE INSTALLATION (CEILING MOUNT ONLY)
1. As needed remove Mounting Plate Assembly (MPA) from Housing Assy (FIG 1) by removing the two (2) M3 screws on the side of the
fixture.
2. Mounting plate Assembly fits onto a 4" octagonal junction box (J-BOX) or other J-Boxes that have a 3-1/2” hole/screw spacing (see
above dimensions). Other j-boxes may also fit. Make sure J-BOX threaded holes will fit MPA holes.
3. Install wiring in 4" octagonal J-BOX (or other j-box) in ceiling, as needed.
4. Connect the power supply wiring from J-BOX to fixture wiring from LED driver in j-box. See "Wiring" instructions below.
5. Secure Mounting Plate Assembly (with LED driver) on j-box (by others), LED driver fits in 4" octagonal j-box, with appropriate
hardware (by others) (FIG 1). Keep wires from Housing Assembly to Mounting Plate Assembly attached. Do NOT pull on wires from
Housing Assembly to LED driver.
6. Align the two (2) tabs on the Mounting plate to the slots in the top of the Housing Assembly (FIG. 1).
7. Tighten M3 screw with #1 screw driver in housing until set screw is flush with outside of housing. Do not over tighten screws.
WIRING
NOTE: Check fixture for input voltage before connecting power to fixture. Connect wiring in j-box. For dimming information (wiring
diagrams, chart, etc.) see LCALDJ2 website page.
1. Connect ground wire (green or bare copper/aluminum) from the supply circuit to the ground wire (green or bare copper) / screw /
connector from the fixture.
2. Connect the neutral (common) wire from the power supply circuit to the neutral wire from the fixture.
3. Connect the main voltage supply wire (line/lead) from the power supply to the line (lead) wire from the fixture.
4. Secure connection using UL Listed wire nuts/connectors and then with UL Listed Electrical tape (by others), as required, appropriate
for the connection.
RELAMPING: Return fixture to Liton for servicing/replacing LED and LED drivers.
CHANGING REFLECTOR (FIG. 4)
1. Remove fixture from mounting surface. Point fixture (A) downward and then lightly press and turn Trim (D) counterclockwise to
unscrew and remove Trim (D) with Glass (C) and Reflector (B) from fixture housing (A).
2. Twist Reflector (B) until tab aligns with Trim (D). Push up and remove Reflector (B) and Glass (C) (as needed) from Trim (D).
3. Replace Reflector (B) with a new Reflector and reverse procedure in steps 1 and 2 above to install trim snug (finger tight) in
housing. Do not over tighten trim in houisng.
WARNING: Always disconnect power before fixture
installation, wiring, or maintenance.
LCALDJ2 HOUSING
ASSEMBLY (1) MOUNTING PLATE ASSEMBLY (MPA)
• #1 and #2 Phillips Head
Screwdriver
• Wire Connectors
• Hardware (screws, nuts, etc.)
• DO NOT USE POWER TOOLS.
ONLY USE HAND TOOLS.
MOUNTING PLATE
ASSEMBLY (MPA)
(With LED Driver)
(1)
M3 X 6mm LONG
FLAT HEAD SCREWS
(2)
3-1/2”
Ø4-3/4”
(HOLES FOR
WIRE EXIT)
(2)
COUNTERSINK
HOLES
(FOR (2)
#8 FLAT HEAD
SCREWS, BY
OTHERS)
Components / Parts (LCALDJ2) Tools RequiredComponents Dimensions
TABS
FIG. 2
TURN TRIM TILL TABS ALIGN ON TRIM
AND REFLECTOR
D
A
B
C
TAB
TAB
TABS ALIGNED
TABS NOT
ALIGNED
3-1/2”
LCALDJ2 HOUSING
ASSEMBLY
MOUNTING PLATE ASSY
(With LED Driver)
M3 X 6mm LONG
FLAT HEAD SCREWS (2)
8-32 FLAT HEAD SCREWS (2)
(BY OTHERS)
4“ OCTAGONAL J-BOX
(BY OTHERS)
TILTS 85° MAX. ROTATES 325° MAX.
AFTER INSTALLATION
TILT AND ROTATE
FIXTURE HEAD TO
PROPER
ORIENTATION
(FIXTURE
HEAD)

INSTALLATION INSTRUCTIONS
CATALOG # :LCALDJ2 SURFACE (WALL MOUNT) SAVE THESE INSTRUCTIONS
L I G H T I N G
Page 2 of 5
Keep these instructions in a safe place for future use/reference.
5461 W. Jefferson Blvd. Los Angeles, CA 90016 • P. 800-515-4880 • F. 800-972-4880 • www.liton.com Product specifications subject to change without notice.
FIG. 3
Important: Please read and understand all instructions
completely before installing this fixture.
WARNING: Fixture installation (and use) and all electrical connections must be in accordance with
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician
install this fixture for you. Fixture should be installed by a qualified electrician.
WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury.
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to
prevent electrical shock.
This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.
WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.
WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture,
Liton's web site or other installations). Also for use with covered ceiling mount.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter (GFCI).
WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain,
or similar combustible material.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter
(GFCI).
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.
Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED
fixture(s)/LED driver(s) on a single circuit.
Do not use any other electrical equipment (example: surge protector photocell, etc.) that
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED
fixture(s)/LED driver(s).
Install remote surge protector(s) (by others, goes on the circuit with nothing between the
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already
installed with a surge protector, to help remove power surges that may harm LED
fixture(s), appropriate for the installation. Periodically check and make sure that your
remote surge protector(s) are in good working order.
WIRING
FIXTURE INSTALLATION (WALL MOUNT ONLY)
1. As needed remove Mounting Plate Assembly (MPA) from Housing Assy (FIG 1) by removing the two (2) M3 screws on the side of the
fixture.
2. Mounting plate Assembly fits onto a 4" octagonal junction box (J-BOX) or other J-Boxes that have a 3-1/2” hole/screw spacing (see
above dimensions). Other j-boxes may also fit. Make sure J-BOX threaded holes will fit MPA holes.
3. Install wiring in 4" octagonal J-BOX (or other j-box) in ceiling, as needed.
4. Connect the power supply wiring from J-BOX to fixture wiring from LED driver in j-box. See "Wiring" instructions below.
5. Secure Mounting Plate Assembly (with LED driver) on j-box (by others), LED driver fits in 4" octagonal j-box, with appropriate
hardware (by others) (FIG 3). Keep wires from Housing Assembly to Mounting Plate Assembly attached. Do NOT pull on wires from
Housing Assembly to LED driver.
6. Align the two (2) tabs on the Mounting plate to the slots in the top of the Housing Assembly (FIG. 3).
7. Tighten M3 screw with #1 screw driver in housing until set screw is flush with outside of housing. Do not over tighten screws.
NOTE: Check fixture for input voltage before connecting power to fixture. Connect wiring in j-box. For dimming information (wiring
diagrams, chart, etc.) see LCALDJ2 website page.
1. Connect ground wire (green or bare copper/aluminum) from the supply circuit to the ground wire (green or bare copper) / screw /
connector from the fixture.
2. Connect the neutral (common) wire from the power supply circuit to the neutral wire from the fixture.
3. Connect the main voltage supply wire (line/lead) from the power supply to the line (lead) wire from the fixture.
4. Secure connection using UL Listed wire nuts/connectors and then with UL Listed Electrical tape (by others), as required, appropriate
for the connection.
RELAMPING: Return fixture to Liton for servicing/replacing LED and LED drivers.
CHANGING REFLECTOR (FIG. 4)
1. Remove fixture from mounting surface. Point fixture (A) downward and then lightly press and turn Trim (D) counterclockwise to
unscrew and remove Trim (D) with Glass (C) and Reflector (B) from fixture housing (A).
2. Twist Reflector (B) until tab aligns with Trim (D). Push up and remove Reflector (B) and Glass (C) (as needed) from Trim (D).
3. Replace Reflector (B) with a new Reflector and reverse procedure in steps 1 and 2 above to install trim snug (finger tight) in
housing. Do not over tighten trim in houisng.
WARNING: Always disconnect power before fixture
installation, wiring, or maintenance.
Components / Parts (LCALDJ2) Tools RequiredComponents Dimensions
LCALDJ2 HOUSING
ASSEMBLY (1)
• #1 and #2 Phillips Head
Screwdriver
• Wire Connectors
• Hardware (screws, nuts, etc.)
• DO NOT USE POWER TOOLS.
ONLY USE HAND TOOLS.
MOUNTING PLATE ASSEMBLY (MPA)
(With LED Driver) (1)
M3 X 6mm LONG
FLAT HEAD SCREWS
(2)
3-1/2”
Ø4-3/4”
(HOLES FOR
WIRE EXIT)
(2)
COUNTERSINK
HOLES
(FOR (2)
#8 FLAT HEAD
SCREWS, BY
OTHERS) MOUNTING PLATE ASSEMBLY (MPA)
01182019
FIG. 4
TURN TRIM TILL TABS ALIGN ON TRIM
AND REFLECTOR
D
A
B
C
TAB
TAB
TABS ALIGNED
TABS NOT
ALIGNED
3-1/2”
MOUNTING PLATE ASSY
(With LED Driver)
M3 X 6mm LONG
FLAT HEAD SCREWS (2)
8-32 FLAT HEAD SCREWS (2)
(BY OTHERS)
4“ OCTAGONAL J-BOX
(BY OTHERS)
ROTATES
325° MAX.
LCALDJ2 HOUSING
ASSEMBLY
TILTS 85° MAX.
TABS
(LED DRIVER)
AFTER INSTALLATION TILT AND
ROTATE FIXTURE HEAD TO PROPER
ORIENTATION
(FIXTURE HEAD)

CATALOG # :
L I G H T I N G
INSTALLATION INSTRUCTIONS
5461 W. Jefferson Blvd. Los Angeles, CA 90016 •P. 800-515-4880 •F. 800-972-4880 •www.liton.com Product specifications subject to change without notice.
SAVE THESE INSTRUCTIONS
Keep these instructions in a safe place for future use/reference.
Page 3 of 5
LCALDJ2 Track Mount with Single (1CCT) or Dual (2CCT) Circuit Track
01182019
Important: Please read and understand all instructions
completely before installing this fixture.
WARNING: Fixture installation (and use) and all electrical connections must be in accordance with
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician
install this fixture for you. Fixture should be installed by a qualified electrician.
WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury.
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to
prevent electrical shock.
This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.
WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.
WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture,
Liton's web site or other installations. Also for use with covered ceiling mount.
WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain, or similar
combustible material.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter
(GFCI).
Fixtures that are not LED:
For installing lampholder, make sure to refer to other instructions within your fixture, as
required. For installing lamps please refer to your lamp manufacturers’ instructions.
LED Fixtures:
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.
Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED
fixture(s)/LED driver(s) on a single circuit.
Do not use any other electrical equipment (example: surge protector photocell, etc.) that
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED
fixture(s)/LED driver(s).
Install remote surge protector(s) (by others, goes on the circuit with nothing between the
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already
installed with a surge protector, to help remove power surges that may harm LED
fixture(s), appropriate for the installation. Periodically check and make sure that your
remote surge protector(s) are in good working order.
FIG. 2
FIG. 3
FIG. 1
Components/Parts LPTM4 Track Mount w/ Single Circuit Track(1CCT) or Dual Track (2 CCT) Tools Required
• No tools
required.
• For single
and dual
circuit track
parts
installation
see Track
Installation
instructions.
LPTM4: TRACK MOUNT (CONNECTED TO FIXTURE)
(in Lower Position - P1) (1) (For use with Single or
Dual Circuit Track)
NO Busbar Stopper
Busbar
Stopper
Ground Connector
(GND)
Neutral (N)
Power (P1)
(Lower
Position)
Neutral
(N)
Ground
(GND)
Power (P1) (Lower) Neutral (N)Ground (GND)
Polarity Line
Power (P2)
(Upper)
Power (P1) Neutral (N)
Ground (GND)
Polarity Line
Track
Polarity
Line
Contact Connector
Power (P1)
(Lower Position)
Ground Connector (GND) Polarity Line (Track)
Locking
Lever
(Track Mount
Outside)
NOTE: Turn Track Mount
1/4 turn (90°) so Ground
Connector is on the
same side of the Track as
the Track Polarity Line.
LPTM4: TRACK MOUNT
(In Upper Position - P2.
For use with only Dual
Circuit Track)
Contact Connector Power (P2)
(Upper
Position)
WARNING: DO NOT
USE Connector or
End Cap without
Busbar Stoppers!
End Cap NO... X
DUAL CIRCUIT TRACK (2 CCT TRACK CHANNEL)
SINGLE CIRCUIT TRACK (1 CCT TRACK CHANNEL)
YES ... O End Cap
(with 1 Neutral)
(with 1 Neutral)
SINGLE and DUAL CIRCUIT TRACK AND PARTS (ORDERED SEPARATELY).
NOT ALL PARTS SHOWN FOR CLARITY
FIXTURE INSTALLATION
WARNING: Use only Liton Track parts (see above and FIG. 1 and 16) with LPTM4 Track Mount (connected to fixture). Do
not use Liton Track LPTM4 Track Mount with any other manufacturers track (system, parts, etc.).
WARNING: To avoid the potential risk of fire and shorting, you should not under any circumstances use the connectors
and end cap without Busbar Stoppers (see above picture with "NO...X" mark) for your track system!
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
1. Install Liton’s Track as per Track Installation Instructions.
2. Note which Liton track type is installed, Single Circuit Track (see FIG. 1) or Dual Circuit Track (see FIG. 2).
CAUTION: Before Installing Track Head in track, make sure power contact conductor is in the right position!
3. When using Single Circuit Track (see FIG. 1 left) make sure the Track Mount "Power" contact connector location is
in the Lower Position - P1 (see above left). When using Dual Circuit Track (see FIG. 2 left) make sure the Track Mount
"Power" contact connector location is either in the Lower position - P1 (see above left) for the Track P1 lower circuit
(see FIG. 1) or in the Upper position - P2 (see above) for the Track P2 upper circuit (see FIG. 2). As needed push up
or down on the Track Mount "Power" contact connector to put connector in the P1 or P2 position. For the Dual Circuit
Track each circuit is rated for 2400 Watts and will allow you to control two individual sets of fixtures.
4. Locate the Track Polarity line and the Ground Connector on the and LPTM4 Track Mount (see above left and FIG. 2
and FIG. 3).
5. Pull down on the Track Mount locking lever and insert the Adapter Contacts in the Liton Single or Dual Circuit Track
slots (see FIG. 3).
6. Rotate Track Mount LPTM4 one quarter (1/4) turn (90 degrees) so that the Track Mount Ground Connector (side
of Track Mount with two contacts) is on the same side of the track as the Track polarity line (see FIG.17) and locking
lever locks back in place. Do NOT rotate Track Mount Ground to the side of the track without the Polarity Lines. Make
sure track lock in place.
7. To remove fixture pull down on the locking lever and rotate 1/4 turn (90 degrees).
When using LPTM4 Track Mount contact connector in Lower Position (P1, see above) with Dual
Circuit Track (see above) the power comes from POWER (P1). If using LPTM4 Track Mount
contact connector in Upper Position (P2, see above center) with Dual Circuit Track the power
comes from POWER (P2).
(Fixture not shown for clarity)
Use the LPTM4 Track Mount contact connector only in the Lower Position (P1, see above) with
Single Circuit Track (see above). The power comes from POWER (P1).

INSTALLATION INSTRUCTIONS
5461 W. Jefferson Blvd. Los Angeles, CA 90016 •P. 800-515-4880 •F. 800-972-4880 •www.liton.com Product specifications subject to change without notice.
L I G H T I N G
LATS (2 CCT) TRACK WIRING DIAGRAM
CATALOG # : Keep these instructions in a safe place for future use/reference.
Page 4 of 5
Important: Please read and understand all instructions
completely before installing this fixture.
WARNING: Fixture installation (and use) and all electrical connections must be in accordance with
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician
install this fixture for you. Fixture should be installed by a qualified electrician.
WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury.
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to
prevent electrical shock.
This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.
WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.
WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture,
Liton's web site or other installations. Also for use with covered ceiling mount.
WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain, or similar
combustible material.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter
(GFCI).
Fixtures that are not LED:
For installing lampholder, make sure to refer to other instructions within your fixture, as
required. For installing lamps please refer to your lamp manufacturers’ instructions.
LED Fixtures:
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.
Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED
fixture(s)/LED driver(s) on a single circuit.
Do not use any other electrical equipment (example: surge protector photocell, etc.) that
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED
fixture(s)/LED driver(s).
Install remote surge protector(s) (by others, goes on the circuit with nothing between the
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already
installed with a surge protector, to help remove power surges that may harm LED
fixture(s), appropriate for the installation. Periodically check and make sure that your
remote surge protector(s) are in good working order.
LP2 Series Track System with 2 Circuit Track (2 CCT/2N) Only
LCALDJ2- LP2 Series Track Mount Connector with 2 Circuit, 2 Neutral (2 CCT / 2N) Track
FOR USE WITH LITON LP2 SERIES TRACK SYSTEM ONLY
SAVE THESE INSTRUCTIONS
01182019
FIG. 3
FIG. 2
FIG. 1
L = Black Wire
1
N = White Wire
2
L = Red Wire
2
N = White Wire
1-1/16"
L2
N2
L1
1-1/4"
1-1/8"
1-3/8"
WIRING (POLARITY) DIAGRAM
L2
20A
Ph 2
N
L1
N1
20A
Ph 1
SWITCH OR DIMMER
N1
1
N2
1N2
CIRCUIT 2
POSITION
CIRCUIT 1
POSITION
LEVER
AT THE
SIDE
KNOB “OFF” AT THIS
LOCATION
TURN LEVER
TO THE END
PUSH
INTO
TRACK
2 Circuit TRACK (2 CCT)
TURN KNOB TO
DESIRED
CIRCUIT NO.
KNOB
EXTENSION
ADAPTER
GUIDE
TRACK HEAD
CONNECTOR
(2 CCT )
TRACK HEAD CONNECTOR
“OFF” POSITION
TRACK HEAD CONNECTOR CIRCUIT 1 & 2 POSITION
TRACK HEAD
CONNECTOR (2 CCT)
Note: If supply wires are short,
use direct Power Supply
Source and connect to relative
terminal as instructed
SURFACE TRACK
WITH 2 CIRCUITS &
2 NEUTRAL
(2 CCT / 2N)
3/16" x 3" LONG
TOGGLE BOLTS
(SUPPLIED)
Ø 5/8"
HOLE
GUIDE LUG ACCESS
HOLES
GROUND WIRE (GREEN)
LOCK
SCREW
LINE 1 WIRE (BLACK)
LINE 2 WIRE (RED)
NEUTRAL 2 WIRE (WHITE)
CONNECT
WIRES TO
JUNCTION BOX
WITH FLEX
CONDUIT
LIVE END, RIGHT SIDE
(POWER FEED. CAT # LP2941
SHOWN). ALSO AVAILABLE FOR
LEFT SIDE (CAT #LP2942)
Track Fixture Installation (120V AC):
WARNING: Always disconnect power before fixture installation, wiring or maintenance!
1. Remove the cover of the Live End (Power Feed, right or left) to expose wires (FIG. 1).
2. With the power off, connect the Cable to the Relative Terminal (See Wiring Diagram above).
3. Insert the Live End (Power Feed, right side shown FIG. 1) into the 2 Circuit Track (2 CCT
TRACK) using the Guide Lug (FIG. 1).
4. Fasten the Lock Screw till it fully locks with the Track (FIG. 1).
5. Make Ø 5/8" holes in the wall or ceiling matching the Toggle Bolts holes are in the Track. Use
Track as template/guide to mark hole locations on ceiling or wall.
6. Install, and secure, the 2 Circuit Track (2 CCT TRACK) to ceiling or wall using the supplied
3/16" x 3" long Toggle Bolts (FIG. 1).
7. On the fixtures 2 Circuit (2 CCT) Tack Head Connector make sure the Lever is on the side and
the Knob is in the "OFF" position" (FIG. #2). Do NOT install the fixture track head into the
track if the Track Head Connector is NOT in this position.
8. Align the fixture Track Head to the 2 CCT Track so that the Adapter Guide is opposite side of
the Track Extension (FIG. 2).
9. Install the fixtures Track Head Connector into the Track (FIG. 2) at the desired location and
turn the Lever on the Track head to the end of the Track Head (FIG. 3).
10. Turn the Track Head Knob to the desired circuit position (FIG. 3).
11. To remove the fixture Track Head Connector from the Track disconnect power (see above
WARNING), and reverse steps 9 and 10 above by turning the Knob to the "OFF" position and
then push Lever to the side of the Track Head Connector (FIG. 2).
The Liton Architectural Track Series
are equipped with four copper
conductors, two separate live
circuits and two independent
neutrals. The body of the track
serves as the ground connection.
The copper conductors have a
circular cross section, and are .088
inches in diameter. Therefore,
these conductors are approxi-
mately 20 percent larger in area
than 12AWG; and this extra gauge
provides additional margin for
loading of the neutral conductor.
SURFACE TRACK AND LIVE END (RIGHT SIDE) SHOWN
FOR CLARITY. OTHER LP2 ACCESSORIES NOT SHOWN.
TWO-PHASE, TWO SWITHCES (40A TOTAL)
(20A + 20A = 40A)
NEUTRAL 1 WIRE (WHITE)

INSTALLATION INSTRUCTIONS
5461 W. Jefferson Blvd. Los Angeles, CA 90016 •P. 800-515-4880 •F. 800-972-4880 •www.liton.com Product specifications subject to change without notice.
L I G H T I N G
LATS (3 CCT) TRACK WIRING DIAGRAM
CATALOG # : Keep these instructions in a safe place for future use/reference.
Page 5 of 5
Important: Please read and understand all instructions
completely before installing this fixture.
WARNING: Fixture installation (and use) and all electrical connections must be in accordance with
local and National Electrical Codes (N.E.C.) rules, regulations and standards. If you are unfamiliar
with installing fixture(s), accessories and/or electrical wiring have a qualified licensed electrician
install this fixture for you. Fixture should be installed by a qualified electrician.
WARNING: RISK OF SHOCK. House electric current can cause painful shock or serious injury.
WARNING: Always disconnect power before fixture installation, wiring, or maintenance.
WARNING: Before starting the wire connections, disconnect the power by turning off the circuit breaker
or removing the fuse at the fuse panel. Turning the power off using the light switch is not sufficient to
prevent electrical shock.
This luminaire must be connected with supply wire/conductors rated at 90°C. Most dwellings built
before 1985 have supply wire rated at 60°C; consult a qualified electrician before installing.
WARNING: Before service insure fixture is cool to touch.
WARNING: Check fixture for input voltage before connecting power to fixture.
WARNING: RISK OF SHOCK. Fixture is suitable for dry locations (unless otherwise stated on fixture,
Liton's web site or other installations. Also for use with covered ceiling mount.
WARNING: Do not install any fixture or assembly (etc.) closer than 6" from any curtain, or similar
combustible material.
Fixture must be installed on a circuit protected by Ground Fault Circuit Interrupter
(GFCI).
Fixtures that are not LED:
For installing lampholder, make sure to refer to other instructions within your fixture, as
required. For installing lamps please refer to your lamp manufacturers’ instructions.
LED Fixtures:
RELAMPING:
Return fixture to Liton for servicing/replacing LED and LED drivers, as required.
Install LED fixture(s)/LED driver(s) only on their own circuit. Do not mix any other
products (Incandescent, Compact Fluorescent, H.I.D. products/fixtures, etc...) with LED
fixture(s)/LED driver(s) on a single circuit.
Do not use any other electrical equipment (example: surge protector photocell, etc.) that
is not (rated) for use with LED fixture(s)/LED driver(s) on the same circuit as LED
fixture(s)/LED driver(s).
Install remote surge protector(s) (by others, goes on the circuit with nothing between the
surge protector and the LED fixture(s)/LED driver(s)), if the fixture is not already
installed with a surge protector, to help remove power surges that may harm LED
fixture(s), appropriate for the installation. Periodically check and make sure that your
remote surge protector(s) are in good working order.
LP3 Series Track System with 3 Circuit Track (3 CCT/1N) Only
LCALDJ2- LP3 Series Track Mount Connector with 3 Circuit, 1 Neutral (3CCT / 1N) Track
FOR USE WITH LITON LP3 SERIES TRACK SYSTEM ONLY
SAVE THESE INSTRUCTIONS
01182019
FIG. 3
FIG. 2
FIG. 1
L = Black Wire
1
L = Black Wire
3
L = Red Wire
2
N = White Wire
1-1/16"
L2
L3
L
N
1
1-1/4"
1-1/8"
1-3/8"
WIRING (POLARITY) DIAGRAM
L2
20A
N
Ph 2
L
N
THREE-PHASE, THREE-SWITCHES (60A)
3
L1
20A
Ph 3
20A
Ph 1
SWITCH OR DIMMER
CIRCUIT 2
POSITION
CIRCUIT 1
POSITION
CIRCUIT 3
POSITION
LEVER
AT THE
SIDE
KNOB “OFF” AT THIS
LOCATION
TURN LEVER
TO THE END
PUSH
INTO
TRACK
3 CIRCUIT TRACK (3
TURN KNOB TO
DESIRED
CIRCUIT NO.
KNOB
EXTENSION
ADAPTER
GUIDE
TRACK HEAD
CONNECTOR
(3 CCT )
TRACK HEAD CONNECTOR
“OFF” POSITION
TRACK HEAD CONNECTOR CIRCUIT 1, 2 & 3 POSITION
TRACK HEAD
CONNECTOR (3 CCT)
Note: If supply wires are short,
use direct Power Supply
Source and connect to relative
terminal as instructed
SURFACE TRACK
WITH 3 CIRCUITS &
1 NEUTRAL
(3 CCT / 1N)
3/16" x 3" LONG
TOGGLE BOLTS
(SUPPLIED)
Ø 5/8"
HOLE
GUIDE LUG ACCESS
HOLES
GROUND WIRE (GREEN)
LOCK
SCREW
LINE 1 WIRE (BLACK)
LINE 2 WIRE (RED)
LINE 3 WIRE (BLACK)
NEUTRAL WIRE (WHITE)
CONNECT
WIRES TO
JUNCTION BOX
WITH FLEX
CONDUIT
LIVE END, RIGHT SIDE
(POWER FEED. CAT # LP3941
SHOWN). ALSO AVAILABLE FOR
LEFT SIDE (CAT #LP3942)
Track Fixture Installation (120V AC):
WARNING: Always disconnect power before fixture installation, wiring or maintenance!
1. Remove the cover of the Live End (Power Feed, right or left) to expose wires (FIG. 1).
2. With the power off, connect the Cable to the Relative Terminal (See Wiring Diagram above).
3. Insert the Live End (Power Feed, right side shown FIG. 1) into the 3 Circuit Track (3 CCT
TRACK) using the Guide Lug (FIG. 1).
4. Fasten the Lock Screw till it fully locks with the Track (FIG. 1).
5. Make Ø 5/8" holes in the wall or ceiling matching the Toggle Bolts holes are in the Track. Use
Track as template/guide to mark hole locations on ceiling or wall.
6. Install, and secure, the 3 Circuit Track (3 CCT TRACK) to ceiling or wall using the supplied
3/16" x 3" long Toggle Bolts (FIG. 1).
7. On the fixtures 3 circuit (3 CCT) Tack Head Connector make sure the Lever is on the side and
the Knob is in the "OFF" position" (FIG. #2). Do NOT install the fixture track head into the
track if the Track Head Connector is NOT in this position.
8. Align the fixture Track Head to the 3 CCT Track so that the Adapter Guide is opposite side of
the Track Extension (FIG. 2).
9. Install the fixtures Track Head Connector into the Track (FIG. 2) at the desired location and
turn the Lever on the Track head to the end of the Track Head (FIG. 3).
10. Turn the Track Head Knob to the desired circuit position (FIG. 3).
11. To remove the fixture Track Head Connector from the Track disconnect power (see above
WARNING), and reverse steps 9 and 10 above by turning the Knob to the "OFF" position and
then push Lever to the side of the Track Head Connector (FIG. 2).
The Liton Architectural Track
Series are equipped with four
copper conductors, three for live
circuits and one for neutral. The
body of the track serves as the
ground connection. The copper
conductors have a circular cross
section, and are .088 inches in
diameter. Therefore, these
conductors are approximately 20
percent larger in area than
12AWG; and this extra gauge
provides additional margin for
loading of the neutral conductor.