LLURIA LB-ART2 User manual

Dinámico directo / Dynamic live
Módulo Artnet / Artnet module
LB-ART2
Lluria se reserva el derecho de modificar las especificaciones.
Lluria reserves the right to modify specications.
1/2
v.2019.01
Módulo basado en el ptrotocolo Artnet para
controlar LEDs con señal SPI sin necesidad de
equipos adicionales.
Permite controlar la instalación en directo.
La conexión se realiza a través de Ethernet.
Dispone de 2 puertos.
Module based on the Artnet protocol to control
LEDs with SPI signal wothout the need for
additional equipment.
It allows to control the live installation.
The connection is made through Ethernet.
It has 2 ports.
Características técnicas /Technical data
IP 20
Voltaje entrada / Input voltage DC 5V - 24V
USB USB 2.0, type B port
Salida data / Data output 8 x 512 canales SPI
Ethernet 2x RJ45, Auto MDI-X, 10/100 MBit/s
Medidas / Dimensions
Temperatura almacenamiento / Storage temperature
92 x 70 x 45 mm
-20~85ºC
Puertos / Ports 2
LEDs APA101, APA102, APA104, APA106,
GS8207, GW6201, GW6205,
LPD1882S, LPD6803, LPD8806,
MBI6120, P9883, SJ1221, SK6812,
SK6822, SM16703, SM16716,
TLS3001, TLS3008, TM1804,
TM1809, TM1812, TM1814, TM1829,
UCS1903, UCS2903, UCS512B3,
UCS8904, UCS9812S, WS2801,
WS2803, WS2811, WS2811S,
WS2812, WS2812B, WS2813,
WS2815, WS2818, WS2822S,
WS2822S Addressing
Temperatura funcionamiento / Operating temperature -10~70ºC
SPI Converter & Direct Connection
Directly connect to a wide range of supported LEDs via two 4-pin
screw terminals. A signal frequency of up to 24 MHz is available.
Supply power over USB or 5 V to 24 V over a 2-pin screw terminal.
Art-Net / Streaming ACN / USB
Network data is directly converted to SPI without the need for
an additional interface. Reliably distribute data from any compatible
software or hardware controller. In addition, simply connect
to the MADRIX®Software over USB.
Supported LEDs
Additional LED types will be supported with future firmware updates.
Quality Output Of 8 Universes
Each device drives up to 1,360 RGB pixels while ensuring responsive
delivery of high-quality signals to each individual LED. You can choose
the output protocol separately for each of the two ports.
Sync Mode & Daisy-Chain Support
MADRIX®Software and hardware allow you to fully synchronize
Art-Net data for all ports and across devices to get an optimal image
on the LEDs without visual interruptions. 2 Ethernet ports allow
linearly daisy-chaining several devices together.
Designed For DIN Rails Or Walls
Its non-conductive enclosure and standardized design for 35 mm
top-hat rails make mounting quick, easy, and safe. 2 extra brackets
are provided for optional wall mounting. 9 indicators quickly show
the device status with the option to turn them off.
Invaluable Features
The device is ready within seconds after startup.
HTP merging is automatically available for two Ethernet sources.
Its firmware is upgradable. Access and change specific device settings
using the built-in web configuration page.
Package Contents
MADRIX® NEBULA
Set of screw terminals (2x 4-pin and 1x 2-pin)
USB 2.0 cable (certified)
2x Wall-mount brackets
Quick start guide / technical manual
MADRIX NEBULA
The flexible pixel tape driver
to directly control
a wide range of digital LEDs.
Key Features 4th Edition – 05/2019
The MADRIX®NEBULA directly connects to your LED pixels.
This advanced SPI decoder receives control data over Ethernet network or USB and is built to provide excellent image quality.
APA101 P9883 TM1814 WS2812
APA102 SJ1221 TM1829 WS2812B
APA104 SK6812 UCS1903 WS2813
APA106 SK6822 UCS2903 WS2815
GS8207 SM16703 UCS512B3 WS2818
GW6201 SM16716 UCS8904 WS2822S
GW6205 TLS3001 UCS9812S WS2822S
LPD1882S TLS3008 WS2801 Addressing
LPD6803 TM1804 WS2803
LPD8806 TM1809 WS2811
MBI6120 TM1812 WS2811S
More Information
Find all the latest user manuals, drivers, firmware updates,
and more at www.madrix.com
(compatible with 1 GBit/s)

Dinámico directo / Dynamic live
Módulo Artnet / Artnet module
LB-ART2
Lluria se reserva el derecho de modificar las especificaciones.
Lluria reserves the right to modify specications.
2/2
v.2019.01
Advertencias /Warnings
· La instalación y el mantenimiento del módulo la deberá realizar personal cualificado.
· Este módulo no es estanca, en instalaciones de exterior o con humedad deberá ir instalada en cajas estancas.
· La instalación en sitios con buena ventilación prolongará la vida útil del módulo.
· Compruebe que la tensión de entrada y de salida están dentro de los parámetros indicados.
· Los picos de tensión pueden causar daños en el módulo.
· Asegure que el cable utilizado en la instalación es de tamaño adecuado.
· Asegure que el cable hace contacto correctamente con el conector.
· Asegure que todas las conexiones de cable y las polaridades son correctas antes de conectar la alimentación.
· The installation and maintenance of the module must be carried out by qualied personnel.
· This module is not watertight, in outdoor installations or with humidity it must be installed in watertight boxes.
· Installation in well ventilated areas will prolong the life of the module.
· Check that the input and output voltage are within the indicated parameters.
· Voltage peaks can cause damage to the module.
· Ensure that the cable used in the installation is of adequate size.
· Ensure that the cable makes proper contact with the connector.
· Ensure that all cable connections and polarities are correct before turning on the power.
Conexiones /Connections
•
1. Potencia / Power
2. Puerto Ethernet derecho / Right Ethernet port
3. Puerto Ethernet izquierdo / Left Ethernet port
4. Puerto USB / USB port
5. Estado LED para potencia / Status LED for power
6. Estado LED para USB / Status LED for USB
7. Estado LED para Puerto 1 / Status LED for Port 1
8. Estado LED para Puerto 2 / Status LED for Port 2
9. Puerto 1 / Port 1
10. Botón resetear / Reset button
11. Clip de desbloqueo del riel DIN / DIN-rail unlocking clip
12. Puerto 2 / Port 2
9
5
1
34
12
10
11
6
7
8
2
Table of contents
Popular Control Unit manuals by other brands

LK
LK WSS Mini Assembly instructions

National Instruments
National Instruments NI 9871 Operating instructions and specifications

Norgren
Norgren VP60 Series Operation manual

GE
GE Baker Hughes 2900-40 Series Maintenance manual

Tyco
Tyco iSTAR Ultra Installation and configuration guide

Barco
Barco CDMS Specifications