manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Logic Controls
  6. •
  7. Control Unit
  8. •
  9. Logic Controls LS6000 User manual

Logic Controls LS6000 User manual

Other manuals for LS6000

1

Other Logic Controls Control Unit manuals

Logic Controls LM3000 User manual

Logic Controls

Logic Controls LM3000 User manual

Logic Controls LM3000 User manual

Logic Controls

Logic Controls LM3000 User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

INSTALLATION GUIDE
LS6000 Logic Net eStation
www.logiccontrols.com
The LS6000 video I/O station is the Ethernet version of Logic Net, the
industry’s leading kitchen video display system solution. A typical system
consists of a host server (PC or POS terminal) where the application software
is installed and a number of LS6000 units. Each LS6000 eStation can be
connected to a VGA monitor, a keyboard, and 2 serial interface devices. The
LS6000 units communicate with the host server via TCP sockets on Ethernet
connections.
HARDWARE INSTALLATION
Component Placement
The following is recommended when you plan the LS6000 system setup:
•Place the LS6000 so that you can use the mounting brackets located
at the bottom of the unit.
•Place the LS6000 so that the RESET button is accessible.
•Place the LS6000 so that the beeps from the speakers can be heard.
•Place the LS6000 so that the LED indicator on the front panel can be
seen.
•Place the LS6000 above grill/counter level, out of the way of possible
spills.
Mounting Instructions
Mounting brackets are provided to facilitate mounting the LS6000 to a wall,
ceiling, or display monitor mounting arm. The installer should insure that the
wall anchors used with the mounting brackets have the capacity to support 4.3
kg (9.5 lb.). This weight is determined by adding a safety margin weight to the
weight of the unit. Wall anchors with specified weight capacity are available
commercially.
Connections
Make sure that all systems are powered off before making or removing any
connections to the LS6000 unit. Follow the steps below in connecting the
devices:
1. Connect the VGA cable of the display monitor to the LS6000.
2. Connect the RS232 cable of serial devices to the LS6000.
3. Connect the keyboard device to the LS6000.
4. Connect the Ethernet cable from Ethernet hub or switch to the
LS6000.
5. Connect power to all peripheral devices and turn on power.
6. Connect power adapter to the LS6000 and power cord to the power
adapter.
7. Plug the power cord into AC power outlet.
8. If necessary, reset the LS6000 by pressing the reset button.
LS6000 SETUP AND SELF-DIAGNOSTIC TESTS
Each time the LS6000 is powered on, it runs a ROM-based setup and
diagnostic program that is used to set system parameters and provide
problem determination information. You can run the program by pressing the
system RESET button. As soon as the system information screen appears,
quickly press [Delete] or [Down Arrow] key on the keyboard to enter Setup
screen.
There are 5 setup menus: MAIN, ETHERNET, SERIAL, DIAGNOSTIC and
EXIT. The menu being displayed is highlighted on the menu bar across the
top of screen. Use left and right arrows to select the menu and use up and
down arrows to select menu item. Menu items that can be changed are
shown in yellow color and highlighted in reverse video when selected. Use
the -/+ keys or 0/1 keys to change the value. For certain items such as IP
address, the numeric keys are used to enter the values.
Logic Controls, Inc.
SYSTEM SETUP
1 Install the LS6000 units as described in HARDWARE INSTALLATION
section.
2 Setup optional LS6000 parameters if necessary (for example, RS232
baud rate and beeper pitch).
3 Setup the station address used for quick identification of the station.
4 Setup IP address, subnet mask and port number to the required values.
Check with system administrator for proper settings. Note that the IP
address must match the IP group of the host server and the TCP port
address must match the port number used by the application software.
5. Save parameters and exit setup.
6 Verify that the values on the boot up screen shows the correct set up
values. If not, repeat step 2 to 5 to correct the settings.
7 You have now completed the setup for one LS6000. Repeat as
necessary for each LS6000 in the system, ensuring a unique IP address
for each LS6000. Always verify your setting on the boot up screen.
8. Setup the host server IP address such that it’s in the same IP group as
the LS6000 units.
9. Setup the application software if necessary.
10. Run the application software or a test program to verify functions of the
system.
GENERAL SPECIFICATIONS
MECHANICAL
Weight
2.25lbs
Dimension (in Inches)
6.3W x 1.0H x 5.1D
ELECTRICAL (Power Adapter)
Input voltage 100 to 240VAC
Input frequency 47 to 63 Hz
Input power 30VA max
Output voltage +5VDC
Output current 1A max
Ripple voltage
< 100mVp-p
ENVIRONMENT
Operating temperature 5ºC to 40ºC
Relative humidity 8 to 80%
Storage temperature 0ºC to 60ºC
Relative humidity
5 to 80%
INTERFACE
To host server Ethernet 10BaseT
VGA Port Standard VGA
Keyboard PS2
Serial Port RS232C
Baud Rate 2400, 4800, 9600, 19200
Parity None
Data Bits
8
CABLES
General Connectors are latched or
with strain relief
Ethernet 8 pin modular RJ45 male
RS232 Standard DB9 female
VGA Standard high density
DB15 male