Description
Suverain 30FFA-A can pump away the waste from a
bath, washing machine, dishwasher, and a sink.
This device is not meant to be used by people (including
children) with limited physical or mental abilities or
a lack of experience and/or knowledge of this or a
similar component. Unless they are supervised by a
person responsible for their safety or receive from them
instructions as to how the device is to be used, the user
should be careful when operating this device. Note that
children should be supervised to ensure that they do not
engage in recreation with this appliance.
Installation
The unit should be accessible for possible maintenance.
a. Connection to side inlets
Take off the caps and insert the non-return valve for
connection of pipes to the side inlets.
Cap off unused inlets with the end caps provided, after
greasing the joints.
b. Connection to lid inlets
To connect to the lid inlet, take off the cap and
connect using the pipe inlet.
c. Connection of bathroom appliances
To connect a shower, ensure that the trap exit is 15 cm
above floor level.
To install a shower next to the unit, connect the pipe to
the inlet spigot.
Secure using the seal and the nut.
WARNING: Ensure that the shower trap exit is 60mm
above ground level.
Installation under the tray : Lift the tray at least
145mm to accomodate the unit.
WARNING: Prepare an access trap to the unit (the access
trap should be built so that tool is required to open it).
Suverain 30FFA-A should always be accessible for
possible maintenance.
d. Discharge connection
The discharge should be in 28mm pipe, in copper or
plastic (PVC, ABS…).
Observe the pumping parameters of the unit (vertical
and horizontal combination).
All horizontal pipes should have a 1% (1cm per metre)
fall on the horizontal run, all the way to the drain.
If a vertical lift is required, it must be made before
the horizontal run. The horizontal run must be vented
(larger pipe)
Your units is equipped with a flexible outlet elbow.
Turn the discharge elbow in the desired direction, then
slide it on to the hose and fix it in place with the metal
hose clip.
• Push the pipe into the flexible discharge pipe and
secure with clip.
TECHNICAL ADVICE FOR DISCHARGE
If the unit is discharging to a point much lower than
the unit (say a floor lower) to avoid siphoning, install
a vacuum breaker (capable of withstanding 10 psi
pressure) at the highest point of the installation.
e. In case of servicing
For possible service requirements, provide a drain off
at the low point of the installation.
f. Connect to the power supply
The electrical installation should be carried by a
qualified person.
The unit should be installed so it is easily accessible/
removable for possible maintenance. All wiring must
conform to BS7671, 1992 requirements for electrical
installations.
The unit requires a 220/240V single phase AC 50 Hz
supply (UK specification). Do not connect the unit to
a conventional plug and socket. The unit should be
connected to a fully earthed electrical supply (class 1).
It must be wired into an unswitched fused fixed wiring
connector protected by a 5 amp fuse and a residual
current detector (30 mA). This connection must be used
exclusively for supplying the unit.
WARNING: Ensure the electricity is turned OFF at the
main switch board before wiring to connector.
All work on cable and motor should only be carried out
by a qualified Lomac servicing agent, as special tools
are required.
Standard
• The unit conforms with EN 12050-2 effluent lifting
station and the European directives and standards
concerning electrical safety and electromagnetic
compatibility.
Care and use
Suverain 30FFA-A is designed to handle the waste
evacuation from a bath domestic kitchen sink,
dishwasher and washing machine - all working at the
same time if required.
Its powerful pump will deal with every day normal usage.
Suverain 30FFA-A will take the above at a heavier duty
rate of usage.
WARNING: Do not dispose of solvents, paints (do
not wash paint brushes in sink), caustic, acid or other
chemicals into these products.
Depending on usage, Suverain 30FFA-A may need to be
cleaned from time to time.
Heavy usage can result in a build up of fat and grease.
Suverain 30FFA-A unit will pump away water as hot as
60°C for a short period. However, do not pour boiling
water directly into the unit.
When the Suverain 30FFA-A is pumping very hot water
for a prolonged period of time, it will automatically
cut out to protect the motor (thermal cut-out).
When this happens Suverain 30FFA-A will shut
down long enough to cool down (approx.1 hour) and
automatically resume normal operation when ready.
Dismantling
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
Disconnect from the power supply before attempting
any work on the unit.
The unit does not require any specific maintenance.
In case of a service requirement, please call own Lomac
service engineer, especially for any electrical work.
Guarantee
This unit is guaranteed for 2 years subject to correct
installation and usage.