Maintenance
Warranty
Keep the surface of the pump clean and dry. Prevent the liquids
from entering the inner of the drive units.
The surface of drive units are not organic solvent and aggressive
liquids resistant. Please pay attention when using.
Note
If a trouble happens, please contact us or our dealers.
The warranty period for this product is one year. If repair or
adjustment is necessary within the warranty period, the problem
will be corrected at no charge if it is not due to misuse or abuse on
your part, as determined by the manufacturer. Repair costs outside
the warranty period, or those resulting from product misuse or
abuse,maybeinvoicedtoyou.
21
Stop State: OC gate is open
Running State: OC gate is close
Infusion: OC gate is open
Withdrawal:OCgateisclose
22
External Control Function
1234
External Control Output Interface
External Control Input and Communication Interface
5678
9101112
13 14 15 16
Channel 1
12345678
(1 2)(5 6)(9 10)(13 14)
are 4 suits OC gates
(3 4)(7 8)(11 12)(15 16)
are 4 suits OC gates
TS-1A/L0107-1A、TS-2A/L0107-2A、TS-1B/W0109-1B
Technical Specifications
System Functions
Parameters Setting: The parameters of each channel can be different
Parameters Saving: The parameters of each channel can be saved
Running Control: Each drive unit can be controlled separately; Or four
drive units can be controlled to run simultaneously or run at
different time
Copy Channel: All drive units can be run according to the parameters of
one drive unit of them
Delaying Startup: Delaying startup time of each channel can be
controlled separately
Memory Function: Select resume operation or remain stopped when
power returns after an interruption
Block Protection: When one drive unit stops accidently, the system will
warm and stop
External Control: Each channel has two ways OC gate output to
indicate the start/stop and running direction of this channel
Communication: Realize computer control through RS485
communication interface
Main Functions for Each Channel
Channel 2 Channel 3 Channel 4
Start/Stop State
Output
Direction State
Output
Port Definition:
1# +5V
2# COM
3# COM for external control start/stop
4# External control start/stop: change to high level, start and stop
states switch
5# NC
6# COM for Rs485
7# RS485 B
8# RS485 A
Note: 1 - 3# are RS485 communication bus ports. Can connect to
the control computer (computer, PLC, SCM).
Syringe Selection: The syringe can be selected in the manufacturer
table which includes manufacturer and size
User-defined Syringe: 4 inner diameter of user-defined syringe barrel
canbeinputandsaved
Working Mode Setting: TS-1A has only infusion working mode. TS-
2A/TS-1B has 5 working modes available: infusion, withdrawal,
infusion/withdrawal, withdrawal/infusion, continuous
Parameters Setting: Set dispensing volume, infusion time, withdrawal
time, pause time and copy number
Display Mode Selection: Different parameters (volume, flow rate,
linear speed) can be selected in the main display interface
FastForward&FastReverse:Infusionorwithdrawalatthemax.speed
Calibration: Acquire accurate volume through calibration
SYRINGE PUMP OPERATING MANUAL SYRINGE PUMP OPERATING MANUAL