Look-C DT17S-D7 User manual

1
LOOK-C INSTRUCTIONS
WES Australasia 2014
2-Wire Video Intercom System
Technical Manual
Contents
DoorEntrySecurity2
2 WIRE DOOR VIDEO INTERCOM SYSTEM 2
2Wire-1Door-1Monitor 2
MINIMUM SYSTEM WITH PC6 2
MINIMUM SYSTEM WITH DPS 2
2Wire-1Door-4Monitors 3
EXPANDED SYSTEM WITH DAISY CHAIN 3
EXPANDED SYSTEM WITH STAR WIRING 3
2Wire-4Doors-1Monitor 3
EXPANDED SYSTEM WITH STAR WIRING 3
2Wire-4Doors-16Monitors 4
EXPANDED SYSTEM MAXIMUM 4
2Wire-CCTVController 5
GENERAL SETUP DCU 5
EXPANDED SETUP DCU 5
2Wire-Duplex6
H292RH DUAL BUTTON SYSTEM 6
H292RH MULTI-MONITORS 6
2Wire-CableInformation 6
RECOMMENDED WIRE SOLUTIONS 6
DoorStrike7
EXAMPLES OF DOOR STRIKE CONNECTION 7
2Wire-AudioOnly8
MINIMUM AUDIO SYSTEM 8
EXPANDED AUDIO SYSTEM 8
EXTENDED VIDEO SYSTEM WITH HANDSETS 8

2LOOK-C INSTRUCTIONS
2 Wire - 1 Door - 1 Monitor
Door Entry Security
2WIREDOORVIDEOINTERCOMSYSTEM
MINIMUMSYSTEMWITHPC6
MINIMUMSYSTEMWITHDPS
Latest in home door intercom innovation Intelligent twin wire system that helps in creating
a quick, simple and economical installation System setup is easy via the comprehensive
yet simple menu system With design and style to suit todays modern home decors
The simplest setup involves a Monitor, a Door Station Camera
and a Bus Power Supply (PC6) Two wire setup as follows:
The simplest setup involves a Monitor, a Door Station Camera
and a Bus Power INJECTOR (DPS) and Requires 24-28Vdc
*Further information available, see Door Strike Info
*Further information available, see Door Strike Info
• No Polarity, twisted pair, easily to wire solution Use CAT5 or twin core drop cable
• One common power supply to all type solution PC6 will run 6 units, more use PS524
• Supports from 1 to a Max of 16 Monitors connected in one system (Use DBC4S)
• Expanding a system to multiple door station cameras with DBC4S (Up to 4 max)
• Each door camera can control 2 locks Door locks are an optional extra (EL971)
• All 2-Wire H2 products are compatible All operate on the same twisted pair wire
• No Polarity, twisted pair, easily to wire solution
• Use CAT5 or twin core drop cable or equivalent
• Cable distances can be up to 100M Total (CAT5)
• One common power supply to all type solution (PC6)
• PC6 is a Mains 240Vac power to 24Vdc injector 12A
• The door camera can control a door strike*
• Door Strike connections may vary to that shown*
• System is expandable with additional components
• No Polarity, twisted pair, easily to wire solution
• Use CAT5 or twin core drop cable or equivalent
• Cable distances can be up to 100M Total (CAT5)
• One common power supply to all type solution (DPS)
• DPS is an injector that requires an external power source
• Requires 24Vdc to 28Vdc with 1A for this minimal system
• Each door camera can control a door strike*
• Door Strike connections may vary to that shown*
• System is expandable with additional components
AC~
Door
Strike*
PC6
Monitor
Impedance DIP-6=on
Monitor 1 DIP=00
1 2 3 4 5 6
ON
Door
Camera
1
2
ON
#1
BUS
DS
BUS
IM
Monitor
Impedance DIP-6=on
Monitor 1 DIP=00
1 2 3 4 5 6
ON
1
2
ON
#1
Door
Camera
Door
Strike*
DC
24V
1.2A+
DPS
BUS
DS
BUS
IU
• Monitors: 1
• Door Camera: 1
• Power Source: PC6
• Dip Switches: Default
• Menu Settings: Default
• Monitors: 1
• Door Camera: 1
• Power Source: DPS
• Dip Switches: Default
• Menu Settings: Default

3
LOOK-C INSTRUCTIONS
Door
Camera
Monitor
On To Further
Optional Monitors
Up To 4 Total
Door
Strike*
PC6
Monitor Monitor Monitor
Impedance DIP-6=off
Monitor #2 DIP=01
1 2 3 4 5 6
ON
Impedance DIP-6=off
Monitor 1 DIP=00
1 2 3 4 5 6
ON
Impedance DIP-6=off
Monitor #3 DIP=02
1 2 3 4 5 6
ON
Impedance DIP-6=on
Monitor 4 DIP=03
1 2 3 4 5 6
ON
1
2
ON
#1
BUS
DS
BUS
IM
AC~
2 Wire - 1 Door - 4 Monitors
2 Wire - 4 Doors - 1 Monitor
EXPANDEDSYSTEMWITHDAISYCHAIN
EXPANDEDSYSTEMWITHSTARWIRING
EXPANDEDSYSTEMWITHSTARWIRING
System can be simply expanded to include 1 to up to 4 monitors using the existing PC6 power
solution and extending the cable in a daisy chain, up to a maximum of 100 metres cable (CAT5)
An alternative wiring system radiating from a single point by use of
the DBC-4S Bus Splitter Allows adding additional monitors, up to 4
Up to four cameras can be connected to a system with the
addition of a DBC-4S Bus Splitter Each Camera Station can
control a door by use of a Door strike PC6 Power Injector is
sufcient to run ALL Door Cameras plus up to four monitors
*Further information available, see Door Strike Info
*Further information available, see Door Strike Info
*Further information available, see Door Strike Info
• No Polarity, twisted pair, easily to wire solution Use CAT5 or twin core drop cable or equivalent
• Cable distance can be up to 100M total when using CAT5 cable (from camera to last monitor)
• One common power supply to all type solution (Use PC6 Mains Power or DPS Power Injector)
• Connect multiple monitors from 2 to 4 on the one Bus with PC6 Power and a Door Camera
• Monitor DIP Switches need setting Monitor Menu needs setting for Master/Slave (See manual)
• DBC-4S Splitter for a Star Wiring alternative
• No Polarity, twisted pair, easily to wire solution
• Use CAT5 or twin core drop cable or equivalent
• Cable distance can be up to 100M when using CAT5 cable
from the Door Camera to the furthest of the monitors
• One common power supply to all type solution (PC6 or DPS)
• Monitor DIP Switches need setting Monitor Menu needs
setting for Master/Slave (See Monitor Instruction Manual)
• DBC-4S Splitter for expanding to extra Door Cameras
• DBC-4S Supports Two to Four Door Camera Stations
• Allows view and control of each Door Camera & Door strike
• Auto switches the monitor to the appropriate camera
• Cameras are internally terminated, so no Impedance switch
to set and Daisy-chain wiring is not available for cameras
• Cable distance can be up to 100M from Camera to Monitor
• PC6 has enough power to supply more Monitors
in a further expanded system (See above) †
• Each door camera can control a door strike*
• Door Strike connections may vary to that shown*
Door
Camera
Monitor
Door
Strike*
PC6 DBC-4S
BUS
DS
BUS
IM
BUS
Monitor Monitor Monitor
Impedance DIP-6=on
Monitor #2 DIP=01
1 2 3 4 5 6
ON
Impedance DIP-6=on
Monitor 1 DIP=00
1 2 3 4 5 6
ON
Impedance DIP-6=on
Monitor #3 DIP=02
1 2 3 4 5 6
ON
Impedance DIP-6=on
Monitor 4 DIP=03
1 2 3 4 5 6
ON
1
2
ON
#1
OFF
ON
Impedance
Switch
AC~
Monitors
AC~
PC6 DBC-4S
BUS BUS
Door
Camera
Door
Strike*
Door
Camera
Door
Camera
Door
Camera
1
2
ON
#1
1
2
ON
#2
1
2
ON
#3
1
2
ON
#4
OFF
ON
Impedance
Switch
BUS
DS
BUS
IM
Single or
Multiple
Monitors
Multiple monitors need to be identied for the
system to operate This is done by changing
DIP Switch settings (1-16) See DIP settings
Multiple monitors need to be identied for the
system to operate This is done by changing
DIP Switch settings (1-16) See DIP settings
Multiple cameras need to be identied for the
system to operate This is done by changing
DIP Switch settings (1-4) See DIP settings
In this conguration, all monitors impedance
switches need to be set to OFF, except the
end (last) monitor’s impedance is set to ON
In this conguration, all the monitors are at the
end of each Bus so their impedance switches
need to be set to ON
In this conguration, only one monitor is shown
Further monitors can be added, see multi-
monitor congurations for further information

4LOOK-C INSTRUCTIONS
2 Wire - 4 Doors - 16 Monitors
EXPANDEDSYSTEMMAXIMUM
An example of the maximum expansion of a system
This layout demonstrates the best conguration for
low noise pictures, dependable operation with good
distance of cable runs using CAT5 or drop cable
When designing a large layout of a Look-C Door
Intercom, you can use this topology of a full system
and then remove any camera or monitor not required
The Master Bus (dotted line) is Daisy-Chain wired to
each of the DBC-4S Bus Splitters, which in turn are
Star-Wired to each unit on a branch Bus
Up to sixteen Monitors can be added to a system
This is the maximum amount of monitors identied on
a system by the monitor ID (See DIP Switches)
A maximum of four cameras can be connected to a
system with the addition of a DBC-4S Bus Splitter
Each Camera Station can control a Door strike
To power this system requires an external 24V 5 Amp
High Current Power supply and DPS Power Injector
See each units instruction manual for further details
*Further information available, see Door Strike Info
• DBC-4S Splitter for expanding to extra Monitors
• Supports up to a maximum of 16 Monitors
• Each Monitor can intercom with any other Monitor
• DBC-4S Splitter for expanding to extra Door Cameras
• Supports Two to Four Door Camera Stations
• Allows view and control of each Door Camera
• Auto switches the monitor to the appropriate camera
• Each door camera can control a door strike*
• Door Strike connections may vary to that shown*
• No Polarity, twisted pair, easily to wire solution
• Use CAT5 or twin core drop cable or equivalent
• Cable distance can be up to 100M from the Camera
• DPS Injector requires a 24V 5 Amp Power Pack
DC
24V
5A+
Monitor
DBC-4S
BUS-DS BUS-IM BUS BUS
Monitor
Monitor
Monitor
Monitor
DBC-4S
BUS BUS
Monitor
Monitor
Monitor
Monitor
DBC-4S
BUS BUS
Monitor
MonitorMonitor
Monitor
DBC-4S
BUS
Monitor
MonitorMonitor
DPS
DBC-4S
BUS BUS
Door
Camera
Door
Strike*
Door
Camera
Door
Camera
Door
Camera
Impedance DIP-6=on
Monitor 1
1
2
3
4
5
6
ON
1
2
ON
#1
Impedance DIP-6=on
Monitor 5
1
2
3
4
5
6
ON
1
2
ON
#2
Impedance DIP-6=on
Monitor 3
1
2
3
4
5
6
ON
1
2
ON
#3
Impedance DIP-6=on
Monitor 7
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 15
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 13
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 11
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 9
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 10
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 12
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 14
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 16
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 2
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 4
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 6
1
2
3
4
5
6
ON
Impedance DIP-6=on
Monitor 8
1
2
3
4
5
6
ON
1
2
ON
#4
OFF
ON
Impedance
Switch
OFF
ON
Impedance
Switch
OFF
ON
Impedance
Switch
OFF
ON
Impedance
Switch
OFF
ON
Impedance
Switch
Multiple monitors need to be identied for the
system to operate This is done by changing
DIP Switch settings (1-16) See DIP settings
Multiple cameras need to be identied for the
system to operate This is done by changing
DIP Switch settings (1-4) See DIP settings
In this conguration, all the monitors are at the
end of each Bus so their impedance switches
need to be set to ON
The master Bus needs to be terminated at
end-of-line This is done by selecting the
DBC-4S Impedance Switch to ON

5
LOOK-C INSTRUCTIONS
2 Wire - CCTV Controller
GENERALSETUPDCU
EXPANDEDSETUPDCU
Multi-function device designed to connect one or
two Standard CCTV Analogue Video Cameras into
the Look-C Two Wire Video Intercom System
Also enables a zone control point for door actuator
or Light with programmable automatic features
The diagram below shows an example of multiple DCU unit setup The DCU is identied as also the Door Cameras with a maximum of four units
Thus you can have a combination of one door station and three DCUs, or three door cameras and one DCU See manual for more information
• Connects CCTV vision into the Look-C System
• One or Two analogue video camera inputs
• Includes 12Vdc power source for the cameras
• If two cameras are connected, then on-screen
viewing is cycled between the two cameras
• Requires at least one Door Camera in system
• Connect Optional Door Actuator or a Light
DPS
1 2 3 4 5 6
ON
DCU
1 2 3 4
ON
AC
Door
Camera
#1
Door
Camera
#2a
Door
Camera
#2b
See Door Strike*
For wiring connections
Monitors
1
2
ON
#2
1
2
ON
#1
Push
Button
Single or
Multiple
Monitors
CoaxPower
DC
24V
5A+
OR
Door
Strike*
1 2 3 4 5 6
ON
DCU #3 #4
1 2 3 4
ON
AC
Door
Camera
#2
1
2
ON
#3
1
2
ON
#2
Push
Button:
Toggle
or Timer
Remote
Control
by
Monitor
No More
Door Cameras
Push
Button
Exit w/
delay
*Wiring
Depends
on Strike
DPS
1 2 3 4 5 6
ON
DCU
1 2 3 4
ON
Monitors
1
2
ON
#4
Exit
Button
Push
Button
Single or
Multiple
Monitors
DC
24V
5A+
Door
Strike*
DBC-4S
BUS
OFF
ON
Impedance
Switch
Door
Camera
#1
Door
Strike*
1
2
ON
#1
*POWER
Door
Camera
#3a & b
The Video Source can be a Camera
or other Composite Video Source.
eg. Connect to your existing DVR
Video Surveillance System, etc.
CoaxPower
Door
Camera
#4a & b
CoaxPower
• See “Examples of Door Strike Connections”
• “Exit Button” with time delay for door actuator
• Requires external power for door actuator
• Wiring connection depends on Door Strike
• DCU Contacts programmed for NO/NC*
OPTIONALDOORACTUATOR
OPTIONALLIGHTCONTROL
• or alternatively you can connect a light
• Light is triggered by push button ON with timer
or Light is toggled on/off by the push-button
or by Door Camera Station #1 call button
or by any monitor viewing the DCU
• DCU uses dry contact relay (Normally Open)
• Relay Contacts up to 240Vac 7A max
Visitor Presses
Door Bell #1
Light Switches
On (for a preset time)
Monitor Shows
Door Camera #1
Visitor Leaving
Presses Exit Button
Door Latch Activates
for X seconds
Monitor Selects
Door Camera #2
Screen Cycles
Cameras #2a & #2b
• Door Bell Pressed on Door Camera #1 or #2 both activate the Light
• Push Button Pressed will activate/de-activate the light (toggle)
• In Auto Mode, the light will stay on for a pre-set delay, then switch off
• In manual mode, light is switched Off by the push button only (Not the Monitor)
Door Bell
Button
123
456
789
0
Exit
Button
Coded
Entry
Keypad
Entry
N/C
Door
Strike
Fail-Safe
Power-OFF-To-Release
Door
Camera
N/C
Power
Supply
DCU
Exit
N/C
Door Bell
Button
123
456
789
0
Exit
Button
Coded
Entry
Keypad
Entry
N/O
Door
Strike
Fail-Secure
Power-ON-To-Release
Door
Camera
N/O
Power
Supply
DCU
Exit
N/O
• Fail-Safe / Power-OFF-To-Release type Door Strike Connections
• DCU allows a programmable Time Delay Activation for Exiting
• Shown with optional Keypad or RFID entry module
• Fail-Secure / Power-ON-To-Release type Door Strike Connections
• DCU allows a programmable Time Delay Activation for Exiting
• Shown with optional Keypad or RFID entry module
DISCONTINUED

6LOOK-C INSTRUCTIONS
2 Wire - Duplex
H292RHDUALBUTTONSYSTEM
H292RHMULTI-MONITORS
The H292RH Door Camera Station is a single camera with two door-bell buttons A & B Monitors are pre-set to ring on either one of the button
presses A or B The door strike is shared and monitors can intercom between each other This makes the H292RH suitable for Duplex Units with
a common door, or share situations in a common dwelling, Dual occupancy, Grannie Flats, Teenagers, Private/Ofce, Business A or B, etc
Two door strikes can be attached, however, both camera systems A & B can control both door strikes
Look-C 2-Wire System is shown here with monitors in Daisy-Chain or a
combination of Splitter and Daisy-Chain with the PS6 Power Injector The system
can be further expanded to more monitors and cameras with the DPS Power
Injector See other 2-Wire diagrams for other extended system examples
Monitor
A
Impedance DIP-6=on
Monitor #1 Button=A
1 2 3 4 5 6
ON
Monitor
B
Impedance DIP-6=off
Monitor #17 Button=B
1 2 3 4 5 6
ON
Duplex
Door
Camera
Power
A
B
Door
Strike*
PC6
AC~
Duplex
B
Duplex
A
• Two separated systems share a single camera
• Door Camera has two Door-Bell Buttons A or B
• Requires a minimum of two Monitors (A & B)
• DIP Switch 5 selects as Monitor for Button A or B
• Monitors control common door strike*
• Door Strike connections may vary to that shown*
• System can expand to a maximum of 16 Monitors
• Monitor at the end of a chain must be terminated
• Door Camera has two Door-Bell Buttons A or B
• DIP Switch 5 selects as Monitor for Button A or B
• Monitors control common door strike*
• Monitor at the end of a chain must be terminated
Monitor
A
Impedance DIP-6=on
Monitor #2 Cam=A
1 2 3 4 5 6
ON
Monitor
B
Impedance DIP-6=off
Monitor #18 Cam=B
1 2 3 4 5 6
ON
Monitor
A
Impedance DIP-6=off
Monitor #1 Cam=A
1 2 3 4 5 6
ON
Monitor
B
Impedance DIP-6=off
Monitor #17 Cam=B
1 2 3 4 5 6
ON
Power
Door
Strike*
PC6
BUS
DS
BUS
IM
AC~
Duplex
A
Duplex
B
Duplex
Door
Camera
A
B
Monitor
A
Power
Door
Strike*
PC6
Monitor
A
Monitor
B
Monitor
B
Impedance DIP-6=off
Monitor #2 Cam=A
1 2 3 4 5 6
ON
Impedance DIP-6=off
Monitor #1 Cam=A
1 2 3 4 5 6
ON
Impedance DIP-6=off
Monitor #17 Cam=B
1 2 3 4 5 6
ON
Impedance DIP-6=on
Monitor #18 Cam=B
1 2 3 4 5 6
ON
BUS
DS
BUS
IM
AC~
Duplex
Door
Camera
A
B
Button A rings Monitor A Button B rings Monitor B
Monitor A and B control the common door strike
Monitor A can intercom with B (and vice-versa)
PC6
Power
DBC-4S
Splitter
DBC-4S
Splitter
A
(Cam)
Monitor Monitor
B
(Master Bus)
C
(Branch)
Monitor
Door
Camera
C
(Branch)
2 Wire - Cable Information
RECOMMENDEDWIRESOLUTIONS
The maximum distance of the wiring is limited on the Look-C 2-Wire system Using different cables may also affect the maximum distance which
the system can reach The cable caries both video and data plus the power, so It is recommended that you use better quality with larger gauge
for best results over longer distances For relatively short distances, under 20 Meters, the cable choice is less critical
• Twisted pair cable is to be used
• For best Monitor Image results:
Keep runs as short as practical
Use larger gauge quality cable
• Maximum distance is approximately
100 Meters from furthest end to end
• Greater distances may be possible by
use of a DBC-4S as an in-line booster
• 24Vdc is suitable for general installs
Results may be improved with 28Vdc
• Be sure to check termination of items
at end of line (Impedance Switch)
Cable Gauge A B C
Twisted cable 2x0.75 mm
260M 40M 20M
Twisted cable 2x1 mm
270M 50M 30M
Twisted cable 2x1.5 mm
Use as a general guide only. Results may vary depending on application.
See Notes for further assistance in gaining distances and image quality.
280M 60M 40M

7
LOOK-C INSTRUCTIONS
Door Strike
EXAMPLESOFDOORSTRIKECONNECTION
• (a) Door Camera Stations can supply power to an electronic lock of Power-On-To-Unlock type with a holding power of no more than 12V
250mA Connection cable should be less than two metres
• (b) For higher power door strikes or longer cabling, an external power source (Local) is required Connection is by dry-contact relay (NO/NC)
Removal of the “Jumper Connector” is required
• (c) The addition of an “Exit Button” is a momentary contact that triggers the door latch for door release
• (d) External Power with “Exit Button” is available
• (2a) Dual Door Strike Connection is available for controlling two door strikes Local power optional (2b)and Exit Button option (2c) or both (2d)
• (e) Power-OFF-To-Release is available and the setting programmed at the monitor Requires external power
• (f) Power-OFF-To-Release Door Strikes x2 (Optional)
• (x) Other options are available See DCU module
*Door
Strike
(a) (b) (c)
*Door
Strike
POWER
SUPPLY
BUS PL S1 S2 SCBUS PL S1 S2 SC
*Door
Strike
EXIT
Button
EXIT
Button
EXIT
Button
BUS PL S1 S2 SC
1 2 3
JUMPER
1 2 3
JUMPER
(d)
POWER
SUPPLY
BUS PL S1 S2 SC
1 2 3
JUMPER
1 2 3
JUMPER
(f)
POWER
SUPPLY
BUS PL S1 S2 SC
1 2 3
JUMPER
DOOR LATCH SECURE
Strike is set as Default
Power-On-To- Release
Note: Exit Button does
Not have actvation delay.
See DCU for time delay.
INTERNAL POWERDOOR LATCH MODE EXTERNAL POWER EXIT BUTTON (Int Pwr)
EXIT BUTTON (Ext Pwr)
BUS PL S1 S2 SC
1 2 3
JUMPER
BUS PL S1 S2 SCBUS PL S1 S2 SC
1 2 3
JUMPER
1 2 3
JUMPER
BUS PL S1 S2 SC
1 2 3
JUMPER
POWER
SUPPLY
DOOR LATCH SECURE
Strikes is set as Default
Power-On-To- Release
Two Door Strikes
POWER
SUPPLY
(x) (e) (x)
*Door
Strike
POWER
SUPPLY
BUS PL S1 S2 SCBUS PL S1 S2 SC BUS PL S1 S2 SC
1 2 3
JUMPER
1 2 3
JUMPER
1 2 3
JUMPER
DOOR LATCH SAFE
Strike can be set as
Power-Off-To- Release
This is programmed into
the door station via the
monitor menu system.
See the Instruction
Manuals for details.
(a) (b) (c) (d)
NOT
AVAILABLE
NOT
AVAILABLE
SEE DCU
Look-C 2-Wire System can control two door strikes per door station These door strikes can be powered by the door station (12Vdc @ 250mA)
or for more current or a higher voltage, you can add an external power source and use the door stations internal relay to activate the door strike
Door strikes are of two types “Fail Secure” is when power is momentarily applied to the strike to allow the door to open (Power-ON-To Release)
“Fail Safe” is when power is always on to hold the door locked, and momentarily switched off to allow the door to open (Power-OFF-To Release)
Release activation is programmed at the monitor for Fail-Secure(Default) / Fail-Safe Activation time is set from 1 to 9 seconds
Exit buttons are usually located on the inside of the premises to allow electronic door release so the person can exit the secured area
Exit buttons are not time delayed and not compatible with Fail-Safe door strikes If these features are required then see the DCU add-on
Door Bell
Button
123
456
789
0
Exit
Button
Coded
Entry
Keypad
Entry
N/C
Door
Strike
Fail-Safe
Power-OFF-To-Release
Door
Camera
N/C
Power
Supply
DCU
Exit
N/C
Door Bell
Button
123
456
789
0
Exit
Button
Coded
Entry
Keypad
Entry
N/O
Door
Strike
Fail-Secure
Power-ON-To-Release
Door
Camera
N/O
Power
Supply
DCU
Exit
N/O
• Fail-Safe / Power-OFF-To-Release type Door Strike Connections
• DCU allows a programmable Time Delay Activation for Exiting
• Shown with optional Keypad or RFID entry module
• Fail-Secure / Power-ON-To-Release type Door Strike Connections
• DCU allows a programmable Time Delay Activation for Exiting
• Shown with optional Keypad or RFID entry module

8LOOK-C INSTRUCTIONS
2 Wire - Audio Only
AC~
Door
Strike*
PC6
Audio
Handset
Door
Station
BUS
IN
BUS
OUT
Impedance DIP-6=on
Monitor 1 DIP=00
1 2 3 4 5 6
ON
1
2
ON
#1
MINIMUMAUDIOSYSTEM
EXPANDEDAUDIOSYSTEM
EXTENDEDVIDEOSYSTEMWITHHANDSETS
The simplest setup involves a Door Station with a Handset
and a Bus Power Supply (PC6) Two wire setup as follows:
The 2-Wire Audio Intercom has the same connection topology as the
Video Intercom 2-Wire system and can be expanded in a similar way
An Audio Only Handset can be used in place of a Video Monitor for
circumstances where audio only communication with the door camera
*Further information available, see Door Strike Info
*Further information available, see Door Strike Info
• No Polarity, twisted pair, easily to wire solution
• Use CAT5 or twin core drop cable or equivalent
• Cable distances can be up to 100M total (CAT5)
• One common power supply to all type solution (PC6)
• PC6 is a Mains 240Vac power to 26Vdc injector
• Each door camera can control a door strike*
• Door Strike connections may vary to that shown*
• System is expandable with additional components
• A maximum of 32 Handsets can be used in one system
• A combination of Daisy-Chain and Star wiring (DBC-4A)
• Set each Door Station & Handset unique ID using the DIP Switches
• End-Of-Line units require termination Set the DIP6=ON
Set all other Handsets in a Daisy-Chain to DIP6=OFF
• PC6 has ample power to supply a fully expanded system
• Each Door Station can control a door strike*
• Door Strike connections may vary to that shown*
• A maximum of 16 Handsets and Monitors can be used in a system
• A combination of Daisy-Chain and Star wiring (DBC-4A) is shown
• Set each Door Station, Monitor & Handset with its own unique ID
• End-Of-Line units require termination Set the DIP6=ON
Set all other Handsets/Monitors in a Daisy-Chain to DIP6=OFF
• DPC with 24Vdc high power to supply a fully expanded system
• Each Door Station can control a door strike*
• Door Strike connections may vary to that shown*
Door
Station
Door
Strike*
Door
Station
Door
Station
Door
Station
DBC-4A
BUS
OFF
ON
Impedance
Switch
AC~
PC6
BUS
DS
BUS
IM
Handset Handset Handset Handset
Impedance DIP-6=off
Monitor 1 DIP=00
1 2 3 4 5 6
ON
Impedance DIP-6=off
Monitor 2 DIP=01
1 2 3 4 5 6
ON
Impedance DIP-6=off
Monitor 3 DIP=02
1 2 3 4 5 6
ON
Impedance DIP-6=on
Monitor 4 DIP=03
1 2 3 4 5 6
ON
1
2
ON
#1
1
2
ON
#2
1
2
ON
#3
1
2
ON
#4
DBC-4A
BUS
OFF
ON
Impedance
Switch
DBC-4A
BUS-IN BUS-OUT
OFF
ON
Impedance
Switch
Monitor
Impedance DIP-6=on
Monitor #1
1 2 3 4 5 6
ON
Monitor
Impedance DIP-6=on
Monitor #4
1
2
3
4
5
6
ON
Monitor Handset
Impedance DIP-6=on
Monitor #6
1
2
3
4
5
6
ON
Handset
Impedance DIP-6=on
Monitor #2
1
2
3
4
5
6
ON
Handset
Impedance DIP-6=on
Monitor #3
1
2
3
4
5
6
ON
DPS
1 2 3 4 5 6
ON
DCU
1 2 3 4
ON
AC
Door
Camera
#3a
Door
Camera
#3b
1
2
ON
#3
Push
Button
CoaxPower
DC
24V
5A+
OR
Door
Strike*
Impedance DIP-6=off
Monitor #5
1
2
3
4
5
6
ON
Door
Camera
#1
Door
Strike*
Door
Camera
#2
1
2
ON
#1
1
2
ON
#2
#3
AC~
Door
Strike*
PC6
Audio
Handset
Door
Station
BUS
DS
BUS
IM
Impedance DIP-6=on
Monitor 2 DIP=01
1 2 3 4 5 6
ON
1
2
ON
#1
Monitor
Impedance DIP-6=off
Monitor 1 DIP=00
1 2 3 4 5 6
ON
DISCONTINUED
This manual suits for next models
2
Table of contents