INSTALLATION INSTRUCTIONS
IR-900-00-B-F-1
IR-900-00-B-W-1
PIR Unit
Power Input 220-240V AC 50/60hz
Working temperature -25°c +55°c
Working humidity <93%RH
Suggested installation height 2.5-3.5m
Detection angle/distance 160° / 10 metres
Connection Connects only to Loxa Plug-and-Play fittings
Remove (unscrew) and store safely the plastic dust cap and ‘O’ ring Aon the
underside of the floodlight. Remove (pull out) and store safely the exposed
jumper Bfrom the three pin female connector.
Note: you will need to replace the dust cap and jumper should you wish to
revert the oodlight to standard (non PIR) operation.
Caution - the jumper must be retted in the ‘at to at’ position as aligned
with the three pin female connector.
Push fit the PIR three pin male connector Cinto exposed three pin female
connector Don the floodlight. The connectors will only fit in the ‘flat to flat’
position. Screw on the retaining ring Eto finger tightness. Do not overtighten.
Setting the PIR Units
It is easiest to initially set the PIR in daylight
1. Turn the ‘day/night’ dial to its fully clockwise
position - which allows the sensor to activate
during daylight.
2. Turn the TIME dial to its fully anticlockwise
position - this sets the unit to its minimum
activation time and allows stage 3 to be
performed more quickly.
3. Turn the ‘day/night’ dial anticlockwise in
small increments (testing the sensor after
each adjustment) until the sensor will not
activate. The sensor should now activate
only in poor light conditions.
4. Set the TIME dial to your preferred
setting between the maximum 20
minutes (fully clockwise) and the
minimum 20 seconds (fully anticlockwise).
The PIR should now activate for your preferred
length of time when triggered during poor
light conditions.
Fine adjustments can be made to activation
settings after some experience of normal
operation is acquired:
Turning the ‘day/night’ dial anticlockwise
will restrict activation to poorer light
conditions.
Turning the TIME dial clockwise will increase
the length of time the unit will activate for
once triggered.
Manual override facility
If the fitting is wired to a manual switch,
the sensor can be overridden by, starting
from the on position, turning the switch
off and back on twice within the space of
three seconds. The fitting will then stay
illuminated until it is manually switched off.
To set the fitting back to sensor control,
switch it off and leave off for fifteen
seconds or more before switching the power
back on.
102 Kirkstall Road
LEEDS LS3 1JA (UK)
www.loxa.co.uk
A
B
D
E
C
FITTING MOUNT
WALL MOUNT
IR-900-00-B-W-1
IR-900-00-B-F-1
INSTALLATION INSTRUCTIONS
Technical HELPLINE: 0330 555 44 33
PC-900-00-B-W-1
Photocell
Power Input 220-240V AC 50/60hz
Working temperature -25°c +55°c
Working humidity <93%RH
Suggested installation height 2.5-3.5m
Detection angle/distance 160° / 10 metres
Operating light levels On : <20 LUX Off : >80 LUX
Connection Connects only to Loxa Plug-and-Play fittings
102 Kirkstall Road
LEEDS LS3 1JA (UK)
www.loxa.co.uk
Operation
The Photocell switch is governed by ambient light levels. Position and fix the
Photocell to a suitable wall where its operation will not be affected by light
from the fitting that it is controlling
Connection
Remove (unscrew) and store safely the plastic dust cap and ‘O’ ring Aon the
underside of the floodlight. Remove (pull out) and store safely the exposed
jumper Bfrom the three pin female connector.
Note: you will need to replace the dust cap and jumper should you wish to
revert the oodlight to standard (non Photocell) operation.
Caution - the jumper must be retted in the ‘at to at’ position as aligned
with the three pin female connector.
Push fit the Photocell three pin male connector Cinto exposed three pin female
connector Don the floodlight. The connectors will only fit in the ‘flat to flat’
position. Screw on the retaining ring Eto finger tightness. Do not overtighten.
Testing
To test for correct operation cover the photocell with the packing box, after
a short delay, 15 - 120 seconds, the photocell will operate and power will be
applied to the load. If tested in bright daylight after a similar delay the photocell
will turn off the power to the load when the packing box is removed.
A
B
D
E
WALL MOUNT
C
3M EXTENSION FLEX1M EXTENSION FLEX
EF-900-00-B-3-1
EF-900-00-B-1-1

This manual suits for next models

1

Popular Security Sensor manuals by other brands

Cassida QUATTRO user manual

Cassida

Cassida QUATTRO user manual

LaserLiner StarFinder operating instructions

LaserLiner

LaserLiner StarFinder operating instructions

Satel OPAL Plus manual

Satel

Satel OPAL Plus manual

Setsquare SET-DOL-RJ installation instructions

Setsquare

Setsquare SET-DOL-RJ installation instructions

hyfire Taurus TAU-MC-01 quick start guide

hyfire

hyfire Taurus TAU-MC-01 quick start guide

Amprobe GSD600 user manual

Amprobe

Amprobe GSD600 user manual

Hubbell SAFETY-SHROUD TWIST-LOCK installation instructions

Hubbell

Hubbell SAFETY-SHROUD TWIST-LOCK installation instructions

Infinite L-com SRAQ-G215 manual

Infinite

Infinite L-com SRAQ-G215 manual

Spectroline AccuMAX XS-555/L manual

Spectroline

Spectroline AccuMAX XS-555/L manual

Somogyi Elektronic home PIR 05/WH instruction manual

Somogyi Elektronic

Somogyi Elektronic home PIR 05/WH instruction manual

Stanley LD200 manual

Stanley

Stanley LD200 manual

PCB Piezotronics W105C02/018C10 Installation and operating manual

PCB Piezotronics

PCB Piezotronics W105C02/018C10 Installation and operating manual

Perry 1SPSP050 instructions

Perry

Perry 1SPSP050 instructions

ORTEC GEM10P4 Configuration guide

ORTEC

ORTEC GEM10P4 Configuration guide

IFM LK81 Series operating instructions

IFM

IFM LK81 Series operating instructions

IP44.de custo control Instructions for use

IP44.de

IP44.de custo control Instructions for use

S-Click CPD-360 instruction manual

S-Click

S-Click CPD-360 instruction manual

Emerson Rosemount 975HR Reference manual

Emerson

Emerson Rosemount 975HR Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.