LT PO2-250 User manual

Pen type, air oxygen and Temp.
O2METER
Model : PO2-250
Y
our purchase of this
OXYGEN METER marks
a step forward for you
into the field o
f
precision measurement.
A
lthough this METER is
a complex and delicate
instrument, its durable
structure will allow
many years of use i
f
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.
OPERATION MANUAL

TABLE OF CONTENTS
1.FEATURES................................................................
.
1
2.SPECIFICATIONS......................................................
.
1
2-1 General Specifications..........................................1
2-2 Electrical Specifications........................................2
3.FRONT PANEL DESCRIPTION..................................... 4
3-1 Oxygen/Temp. Sensor.........................................
.
4
3-2 Power Button...................................................... 4
3-3 Hold Button........................................................
.
4
3-4 REC ( Max./Min. ) Button.....................................
.
4
3-5 LCD Display........................................................
.
4
3-6 Battery Compartment/Cover.................................4
4.MEASURING PROCEDURE.......................................... 5
4-1 O2 ( Air oxygen )/Temp. ( Air Temp. )
measurement..................................................... 5
4-2 Data hold............................................................5
4-3 Data Record ( Max., Min. reading)........................ 5
4-4 Auto power off.................................................... 6
4-5 Set the Temp. unit ( , ) with default..............℃℉ 6
5.CALIBRATION....................................................... 7
6.BATTERY REPLACEMENT...........................................
.
7

1. FEATURES
* O2 ( Air oxygen ) and Temp. ( Air Temp. ) measurement.
* O2 measurement range : 0 to 30.0 % x 0.1 %.
* O2 Buzzer warning : If the measurement value < 18.0
%O2, the buzzer will sound for warning.
* Temp. measurement range : 0 to 50 , / .℃℃℉
* Galvanic cell type for O2 sensor.
* High reliability Oxygen sensor, not be affected by
acidic gases like CO2.
* Oxygen sensor with temperature compensated.
* Data hold, to freeze the desired reading value.
* Auto power off saves battery life.
* Operates from DC 1.5V ( UM4/AAA ) x 4 PCs batteries.
* Microprocessor circuit ensure high accuracy, and also
and also provides special functions and features.
* Durable and compact ABS-plastic housing.
* Application : O2 monitor/dectors, Food industrial (
Refrigerator, Vegetable factory ), Bio-Technology (
Oxygen incubator, Anaerobic cultivator ), Security
system ( Air conditioner and Oxygen shortage alarm
system, Fire alarm system ), Fuel cell system.
2. SPECIFICATIONS
2-1 General Specifications
Display LCD size : 28 mm x 19 mm.
Measurement O2 ( Air oxygen )
Temperature ( Air Temp. )
Sensor Oxygen Galvanic cell type
Temperature Thermistor
1

Circuit Custom one-chip of microprocessor LSI
circuit.
Data Hold Freeze the display reading.
Sampling Time Approx. 1 second.
Power off Auto shut off saves battery life.
Operating 0 to 50 .℃
Temperature
Operating Less than 80% R.H.
Humidity
Power Supply DC 1.5 V battery ( UM4/AAA ) x 4 PCs.
Power Current Approx. DC 4.0 mA
Weight 194 g/ 0.43 LB.
Dimension 180 x 40 x 40 mm (7.1" x 1.6" x 1.6")
Accessories Instruction manual.....................
.
1 PC
Included Soft carrying case ( CA-52A )......
.
1 PC
Application * O2 monitor/dectors.
* Food industrial :
Refrigerator, Vegetable factory
* Bio-Technology :
Oxygen incubator, Anaerobic cultivator
* Security system :
Air conditioner and Oxygen shortage
alarm system, Fire alarm system
* Fuel cell system.
2

2-2 Electrical Specifications (23±5 )℃
O2 ( Air oxygen )
Range 0 to 30 %O2.
Resolution 0.1 %O2.
Accuracy ± ( 1 % reading + 0.2 % O2 ).
@ After calibration
Response time 15 seconds.≦
@ t 90
Overload 100 %O2.
protection
Environment 0.9 to 1.1 atmosphere.
pressure range
Expected life 2 years.≧
time
Alarm If the measurement Air oxygen value
< 18.0 %O2, the buzzer wll sound
for warning.
Temperature ( Air Temp. )
Range 0 to 50 ,32 to 122 .℃℃℉ ℉
Resolution 0.1 degree
Accuracy - ± 0.8 .℃℃
- ± 1.5 .℉℉
@ Above specification tests under the environment RF Field Strength less than
3 V/M & frequency less than 30 MHz only.
3

3. FRONT PANEL DESCRIPTION
Fig. 1
3-1 Oxygen/Temp. Sensor
3-2 Power Button
3-3 Hold Button
3-4 REC Button
3-5 LCD Display
3-6 Battery Compartment/Cover
4

4. MEASURING PROCEDURE
4-1 O2 ( Air oxygen )/Temp. ( Air Temp. )
measurement
1)Power on the meter by pressing the " Power Button "
( 3-2, Fig. 1 ) once,
* Press the " Power Button " once again will power off.
2)Locate the " Oxygen/Temp. Sensor " ( 3-1, Fig. 1 )
to the position that intend to make the measurement.
The upper Display ( 3-5, Fig. 1) will show the O2 ( Air
oxygen ) value in the unit of " %O2 ".
The lower Display ( 3-5, Fig. 1) will show the
Temperature ( Air Temp. ) value in the unit of " " or℃
" ".℉
O2 Buzzer warning
If the measurement value < 18.0 %O2, the
buzzer will sound for warning.
O2 Buzzer warning disable
Power off the meter, press the " REC Button "
( 3-4, Fig. 1 ) continuously then power on the
meter ( press the " Power Button " once ), the
O2 buzzer warning function will be disable.
4-2 Data hold
1)During the measurement, press the " Hold Button "
( 3-3, Fig. 1 ) momentarily to hold the measured
value. The LCD will show a " HOLD " symbol.
2)Press the" Hold Button " once again to release the
data hold function.
4-3 Data Record ( Max., Min reading )
1)The Data Record function can memorize the maximum
and minimum readings. Press the " REC Button " ( 3-4,
Fig. 1 ) once to start the Data Record function and
there will be a " REC " symbol on the display.
5

2)With the " REC " symbol on the display :
a)Press the " REC Button " ( 3-4, Fig. 1 ) once, the
" REC MAX " symbol along with the maximum value
will appear on the display.
* If intend to delete the maximum value, just press
the " Hold Button " ( 3-3, Fig. 1 ) once, then the
display will show the " REC " symbol only & execute
the memory function continuously.
b)Press the " REC Button " ( 3-4, Fig. 1 ) again, the
" REC MIN " symbol along with the minimum value
will appear on the display.
* If intend to delete the minimum value, just press
the " Hold Button " ( 3-3, Fig. 1 ) once, then
the display will show the " REC " symbol only &
execute the memory function continuously.
c)To exit the memory record function, just press the
" REC " button for 2 seconds at least. The display will
revert to the current reading.
4-4 Auto power off
1)In order to prolong the battery life, the instrument
has "Auto Power Off " function. The meter will
switch off automatically if no buttons are pressed
for around 10 minutes.
2)If intend to disable the " Auto power off " mode, then
just execute the " Data Record " function ( Refer to
chapter 4-3, page 5 ).
4-5 Set the Temp. unit ( , ) with default℃℉
1)Power OFF the meter.
2)Press the " Hold Button " ( 3-3, Fig. 1 ) continuously,
use another finger power ON the meter ( press the "
Power Button " once ), until the Temp. unit ( or )℃℉
is presented on the Display then release the " Hold
Button ", the Temp. unit will change From to ( or℃℉
to ) with default.℉℃
6

5. CALIBRATION
1)Due to the air oxygen value is 20.9 % typically, so use
the environment air oxygen value for quick & precise
calibration)
Please make calibration procedures under wide and
ventilating environment for best effect.
2)Power on the meter, Wait 3 minutes at least until the
display reading values become stable & no fluctuation.
3)Use the two fingers to press both the " Hold Button "
( 3-3, Fig. 1 ) and the " REC Button " ( 3-4, Fig. 1 ) at
the same time. Until the upper Display show the text
" CAL " ( the lower Display will show the value 20.9 ),
release the two fingers from the buttons, the text
" CAL " will flashing within several seconds, then the
Display will return to normal screen and show O2
value to " 20.9 ± 0.1 %O2 " and finish the calibration
procedures.
6. BATTERY REPLACEMENT
1)Replace the batteries when the left corner of the LCD
displays the low battery icon " ".
2)Prepare 4 fresh 1.5 V ( UM4, AAA ) batteries.
3)To change the batteries, open ( rotate clockwise direction )
the " Battery Cover " ( 3-6, Fig. 1 ).
4)Make sure the " Battery cover " (3-6, Fig 1) is secured
after changing the batteries.
71010-PO2250
Table of contents
Popular Measuring Instrument manuals by other brands

MONTREL TECNOLOGIA
MONTREL TECNOLOGIA ADR Multi 4000 Operation manual

Hioki
Hioki Memory HiCorder MR6000 instruction manual

Endress+Hauser
Endress+Hauser PROline promag 53 operating instructions

Tecnosystemi
Tecnosystemi Toolsplit 11131043 user manual

Hanna Instruments
Hanna Instruments HI 747 quick start guide

Kane International
Kane International AUTO600 manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS M606B01 Installation and operating manual

ENCARDIO RITE
ENCARDIO RITE EAN-26CCJ user manual

akkuteam
akkuteam VAS 5581 operating instructions

Agilent Technologies
Agilent Technologies U1731A quick start guide

HITADO
HITADO SUPER GL 2 instruction manual

Mecon
Mecon RE 250 Operating instruction