1
Triac/ELV
Push DIM
Triac/ELV
Push DIM
LM-36-24-G1T2
LM-36-12-G1T2
www.ltech-led.com
Technical Specs
LM-36-12-G1T2LM-36-24-G1T2
50/60Hz
84% 85%
12Vdc ± 0.5Vdc24Vdc ± 0.5Vdc
3600Hz
ta: -20 ~ 50°C tc: 90°C
-40°C ~ 80°C, 10~95%RH
±0.03%/°C(0-50°C)
Max. 3A
Max. 1.5A
12Vdc24Vdc
≤200mV
Max. 36W
0~36W
≥102%
Leading edge (Triac), Trailing edge (ELV) phase-cut and Push DIM.
220-240Vac
≤0.2A/230Vac
L-N: 2kV
Max. 0.5mA
PF>0.95/230Vac , at full load
230Vac@THD<10%, at full load
Shut down the output when non-load voltage≥26V,
re-power on to recover after fault condition is removed.
OUTPUT
Model
INPUT
ENVIRONMENT
PROTECTION
SAFETY &
EMC
Ripple & Noise
PWM frequency
Dimming range
Strobe level
Output voltage range
Output voltage
Output current
Output power range
Output power
Overload power limitation
Leakage current
Control surge capability
Inrush current(typ.)
Efficiency (typ.)
Power factor
Input current
Frequency
Input voltage
Dimming interface
THD
Working temperature
Working humidity
Storage Temperature humidity
Temperature coefficient
Vibration
Withstand voltage
Isolation resistance
Over-heat protection
Over load protection
Short circuit protection
Over voltage protection
Intelligently adjust or turn off the output current if the PCB temperature ≥110°C, and recover automatically .
High frequency exemption level.
dimming down to 0.1%
0~100%,
Cold start 30A at 230Vac
20 ~ 95%RH, non-condensing
10~500Hz, 2G 12min./1cycle, 72 min for X, Y and Z axes respectively .
I/P-O/P: 3750Vac
I/P-O/P: 100MΩ/500VDC/25°C/70%RH
Shut down the output when current load≥102%, and recover automatically .
Shut down the output when non-load voltage ≥13V,
re-power on to recover after fault condition is removed.
Shut down automatically if short circuit occurs, and recover automatically .
Safety Standards
EMC Emission
EN61347-1,EN61347-2-13,EN62493
GB19510.1,GB19510.14
EN61347-1,EN61347-2-13,EN62384
KC61347-1,KC61347-2-13
AS61347-1,AS61347-2-13
EN61347-1,EN61347-2-13,EN62384
IEC61347-1,IEC61347-2-13
IEC61347-1,IEC61347-2-13
GB/T17743,GB17625.1
CCC
TUV
CE
KC
RCM
ENEC
CB
EAC
EN55015,EN61000-3-2,EN61000-3-3,EN61547
KN15,KN61547
EN55015,EN61000-3-2,EN61000-3-3,EN61547
CCC
CE
KC
RCM
China
Germany
European Union
Korea
Australia
CB member states
Europe
Russia
China
European Union
Korea
Australia
IEEE 1789
210×43×30mm(L×W×H)
213×44×33mm(L×W×H)
210g±10g
EN61000-4-2,3,4,5,6,8,11, EN61547
OTHERS Dimension
Package Size
Weight(G.W.)
EMC immunity
Strobe test standard
IEC62493,IEC61547,EH55015
EAC Russia
(The certification icons represent on-going certification applications only, and final certification qualification is subject to actual products. )
短路保护短路保护
短路保护
Short circuit
protection
Overload
protection
过温保护过温保护
过温保护
Overheat
protection
V
Over voltage
protection
Achieve high frequency exemption level.
Flicker-free
IEEE 1789
Small size and light weight. Adopt SAMSUNG/COVESTRO V0 flame
resistant polycarbonate protective housings.
The design of dismountable end cap allows you to adjust the length
of housing depending on your needs.
Withsoft-onandfadeinfunction,visualmorecomfortable.
Dimming range: 0~100%, dimming down to 0.1%.
0-100% flicker-free, High frequency exemption level.
Leading edge (Triac), Trailing edge (ELV) phase-cut and Push DIM.
The secure and reliable design for signal isolation.
Innovative thermal management technology intelligently protects the
lifetime the driver.
Over load / Over temp. / Short circuit / Over voltage protection,
recover automatically.
Suitable for internal lights application for Ⅰ/Ⅱ/Ⅲ.
Upto50000-hourlifetime.
5 year warranty (Rubycon capacitor).
The driver is suitable for connecting resistor current-limiting LED fixture (e.g. LED strip). The inrush current will be dozens of times increased if connecting built-in constant current IC current-limiting LED fixtures, the driver will activate the overloaded
protection (hiccups flickering). When you order, please remark controlling the constant current LED fixture (e.g. MR16 lamp, underground light, LED wall washer, constant current LED strip, etc.), then we can prepare the special programs.
LED (Constant Voltage)
Intelligent Driver
440×218×235mm(L×W×H) 60pcs/ctn 13.4kg±5%/ctn
Carton Size
Triac/ELV
Push DIM
Triac connection
Push DIM connection
2
0~100%dimming
Short press to on/off,
long press to dim.
Push DIM
N
L
0~100%dimming
L
N
TRIAC
N
L
L1
LED+
N
L
L1
LED+
Push Dimming
LM-36-24-G1T2
LM-36-12-G1T2
www.ltech-led.com
Dimensions
Unit: mm
Wiring Diagram
Reset switch
On/off control: Short press.
Stepless dimming: Long press.
With every other long press, the brightness goes to the opposite direction.
Dimmingmemory:Thelightswillreturntoitsprevious brightnessvaluewhenshortpressonPUSHDIMbutton.
Poweronagainafterpowercut,theoutputbrightnessissubjectedtotheinputvoltageofdrivers.
Wire diameter:0.5-1.5 (20-16AWG)
Strip length:8mm-9mm
Wire diameter:0.75-1.5 (20-16AWG)
Strip length:8mm-9mm
Push DIM is invalid for DC voltage input.
Dimming interface priority: Triac first, Push DIM next.
210
43
30
170
35
157
Tension plate Remove the protective housing
Push the tension plate down to fix the electric wires. Pull the bottom left and right from the bottom to remove it.
Push the side plate outwards and
remove the tension plate by prying
it up with a tool at the same time.
Protective Housing Application Diagram
3
LM-36-12-G1T2
LM-36-24-G1T2
PF PF
THD【%】THD【%】
VO【V】VO【V】
70
70
75
75
80
80
85
85
90
90
95
95
50
50
60
60
70
70
80
80
90
90
100
100
AC230V/50Hz
AC230V/50Hz
0.80
0.80
0.85
0.85
0.90
0.90
0.95
0.95
1.00
1.00
50
50
60
60
70
70
80
80
90
90
100
100
AC230V/50Hz
AC230V/50Hz
AC230V/50Hz
AC230V/50Hz
0
8
10
12
14
16
50 60 70 80 90 100
0
8
10
12
14
16
50 60 70 80 90 100
AC230V/50Hz
0
2
4
6
8
10
12
14
3 3.15 3.3 3.45 3.6
0
4
8
12
16
20
24
1.5 1.575 1.65 1.725 1.8
AC230V/50Hz
Triac/ELV
Push DIM
LM-36-24-G1T2
LM-36-12-G1T2
www.ltech-led.com
Relationship Diagrams
IO【A】
Efficiency vs Load
Efficiency【%】
Power Factor Characteristic
Load【%】
THD vs Load Over Load Diagram
Load【%】
Load【%】
IO【A】
Efficiency vs Load
Efficiency【%】
Power Factor Characteristic
Load【%】
THD vs Load Over Load Diagram
Load【%】
Load【%】
≥15cm
≥15cm
≥15cm
≥15cm
≥15cm
Installation Precautions
Triac/ELV
Push DIM
LM-36-24-G1T2
LM-36-12-G1T2
4
Warranty Agreement
Attentions
Products shall be installed by qualified professionals.
LTECH products are non-waterproof (special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure it is mounted
in a water proof enclosure.
Good heat dissipation will extend the working life of products. Please ensure good ventilation.
Please check if the working voltage used complies with the parameter requirements of products.
The diameter of wire used must be able to load the light fixtures you connect and ensure the firm wiring.
This manual is subject to changes without further notice. Product functions depend on the goods. Please feel free to contact our
official distributors if you have any question.
Warranty exclusions below:
No any contract signed by LTECH.
Warranty labels and barcodes have been damaged.
Damage caused by natural disasters and force majeure.
Products with severe physical damage.
Beyond warranty periods.
Warranty periods from the date of delivery : 5 years.
Free repair or replacement services for quality problems are provided within warranty periods.
Any artificial damage caused by high voltage, overload, or improper operations.
1. Repair or replacement provided is the only remedy for customers. LTECH is not liable for any incidental or consequential damage
unless it is within the law.
2. LTECH has the right to amend or adjust the terms of this warranty, and release in written form shall prevail.
Before you power on products, please make sure all the wiring is correct in case of incorrect connection that causes damage to light fixtures.
If a fault occurs, please do not attempt to fix products by yourself. If you have any question, please contact your suppliers.
Brightness
0 .1 %
1%
5%
30%
40%
70%
90%
100%
10%
20%
50%
60%
80%
Frequency(Hz)
Modulation(%)
1.00%
10.00%
100.00%
0.10%
110 100 1000 100003125
Flicker Test Table
IEEE 1789
f
f
≤ 8Hz
≤ 10Hz
Limit value (%)
Exemption assessment
(High frequency exemption)
f
f
f
f
f
f
f
f
f
f
≤ 90Hz
≤ 90Hz
≤ 1250Hz
≤ 3125Hz
8Hz <
10Hz <
90Hz <
90Hz <
> 1250Hz
> 3125Hz
0.2
0.1
0.025 ×
0.01 ×
0.08 ×
(0.08/2.5) ×
Limit Value of Modulation in Low Risk Areas
Waveform frequency of Optical output
Exemption assessment
Limit Value of Modulation in No Effect Areas
Waveform frequency of Optical output Limit value (%)
Modulation Area
High Frequency Exemption Area
Marks in the right chart are tested results of different current levels.
The output frequency is 0Hz in 100% brightness and its corresponding
modulation is 0%, which could not be shown in the right chart.
Update Log
Version Update Content
Updated Time
A0 Original version.
2021.04.12
Updated by
Xu Shujun
A1 Updated the silkscreen on the product.
2021.12.27 Xu Shujun
Update Time: 27/12/2021_A1
www.ltech-led.com

This manual suits for next models

1

Popular Power Supply manuals by other brands

Pulsar Rack Power RSFUPS108 manual

Pulsar

Pulsar Rack Power RSFUPS108 manual

Matsusada Precision R4K-36 Series instruction manual

Matsusada Precision

Matsusada Precision R4K-36 Series instruction manual

SEW-Eurodrive MOVIDRIVE MDR60A1320-503-01 operating instructions

SEW-Eurodrive

SEW-Eurodrive MOVIDRIVE MDR60A1320-503-01 operating instructions

Micro Technic Micronix PC/104 Power Supply PV-1075-CAR Installation and user manual

Micro Technic

Micro Technic Micronix PC/104 Power Supply PV-1075-CAR Installation and user manual

L&S BASE quick start guide

L&S

L&S BASE quick start guide

Huawei TP48200A-HT15D3 user manual

Huawei

Huawei TP48200A-HT15D3 user manual

REUTER Cleanox 1.0 operating instructions

REUTER

REUTER Cleanox 1.0 operating instructions

Mission Critical NEWMAR Sentinel Installation & operation manual

Mission Critical

Mission Critical NEWMAR Sentinel Installation & operation manual

Akyga AK-ND-08 user manual

Akyga

Akyga AK-ND-08 user manual

XPG Core Reactor Gold Series quick start guide

XPG

XPG Core Reactor Gold Series quick start guide

Phoenix Contact Basicline 2 Series user manual

Phoenix Contact

Phoenix Contact Basicline 2 Series user manual

GW Instek PSB-2000 series user manual

GW Instek

GW Instek PSB-2000 series user manual

GST PSU24-10 Installation and operation manual

GST

GST PSU24-10 Installation and operation manual

DuraComm LPB-12H owner's guide

DuraComm

DuraComm LPB-12H owner's guide

INIM Electronics SmartLevel SPS24060G Installation and programming manual

INIM Electronics

INIM Electronics SmartLevel SPS24060G Installation and programming manual

National Instruments RMX-4120 Safety & installation instructions

National Instruments

National Instruments RMX-4120 Safety & installation instructions

Extron electronics PS 124 installation manual

Extron electronics

Extron electronics PS 124 installation manual

Pulsar PSBEN 10A12C manual

Pulsar

Pulsar PSBEN 10A12C manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.