www.ltech-led.com
Technical Specs
LM-36-12-G1T2LM-36-24-G1T2
50/60Hz
84% 85%
12Vdc ± 0.5Vdc24Vdc ± 0.5Vdc
3600Hz
ta: -20 ~ 50°C tc: 90°C
-40°C ~ 80°C, 10~95%RH
±0.03%/°C(0-50°C)
Max. 3A
Max. 1.5A
12Vdc24Vdc
≤200mV
Max. 36W
0~36W
≥102%
Leading edge (Triac), Trailing edge (ELV) phase-cut and Push DIM.
220-240Vac
≤0.2A/230Vac
L-N: 2kV
Max. 0.5mA
PF>0.95/230Vac , at full load
230Vac@THD<10%, at full load
Shut down the output when non-load voltage≥26V,
re-power on to recover after fault condition is removed.
OUTPUT
Model
INPUT
ENVIRONMENT
PROTECTION
SAFETY &
EMC
Ripple & Noise
PWM frequency
Dimming range
Strobe level
Output voltage range
Output voltage
Output current
Output power range
Output power
Overload power limitation
Leakage current
Control surge capability
Inrush current(typ.)
Efficiency (typ.)
Power factor
Input current
Frequency
Input voltage
Dimming interface
THD
Working temperature
Working humidity
Storage Temperature humidity
Temperature coefficient
Vibration
Withstand voltage
Isolation resistance
Over-heat protection
Over load protection
Short circuit protection
Over voltage protection
Intelligently adjust or turn off the output current if the PCB temperature ≥110°C, and recover automatically .
High frequency exemption level.
dimming down to 0.1%
0~100%,
Cold start 30A at 230Vac
20 ~ 95%RH, non-condensing
10~500Hz, 2G 12min./1cycle, 72 min for X, Y and Z axes respectively .
I/P-O/P: 3750Vac
I/P-O/P: 100MΩ/500VDC/25°C/70%RH
Shut down the output when current load≥102%, and recover automatically .
Shut down the output when non-load voltage ≥13V,
re-power on to recover after fault condition is removed.
Shut down automatically if short circuit occurs, and recover automatically .
Safety Standards
EMC Emission
EN61347-1,EN61347-2-13,EN62493
GB19510.1,GB19510.14
EN61347-1,EN61347-2-13,EN62384
KC61347-1,KC61347-2-13
AS61347-1,AS61347-2-13
EN61347-1,EN61347-2-13,EN62384
IEC61347-1,IEC61347-2-13
IEC61347-1,IEC61347-2-13
GB/T17743,GB17625.1
CCC
TUV
CE
KC
RCM
ENEC
CB
EAC
EN55015,EN61000-3-2,EN61000-3-3,EN61547
KN15,KN61547
EN55015,EN61000-3-2,EN61000-3-3,EN61547
CCC
CE
KC
RCM
China
Germany
European Union
Korea
Australia
CB member states
Europe
Russia
China
European Union
Korea
Australia
IEEE 1789
210×43×30mm(L×W×H)
213×44×33mm(L×W×H)
210g±10g
EN61000-4-2,3,4,5,6,8,11, EN61547
OTHERS Dimension
Package Size
Weight(G.W.)
EMC immunity
Strobe test standard
IEC62493,IEC61547,EH55015
EAC Russia
(The certification icons represent on-going certification applications only, and final certification qualification is subject to actual products. )
短路保护短路保护
短路保护
Short circuit
protection
Overload
protection
过温保护过温保护
过温保护
Overheat
protection
V
Over voltage
protection
Achieve high frequency exemption level.
Flicker-free
IEEE 1789
Small size and light weight. Adopt SAMSUNG/COVESTRO V0 flame
resistant polycarbonate protective housings.
The design of dismountable end cap allows you to adjust the length
of housing depending on your needs.
Withsoft-onandfadeinfunction,visualmorecomfortable.
Dimming range: 0~100%, dimming down to 0.1%.
0-100% flicker-free, High frequency exemption level.
Leading edge (Triac), Trailing edge (ELV) phase-cut and Push DIM.
The secure and reliable design for signal isolation.
Innovative thermal management technology intelligently protects the
lifetime the driver.
Over load / Over temp. / Short circuit / Over voltage protection,
recover automatically.
Suitable for internal lights application for Ⅰ/Ⅱ/Ⅲ.
Upto50000-hourlifetime.
5 year warranty (Rubycon capacitor).
The driver is suitable for connecting resistor current-limiting LED fixture (e.g. LED strip). The inrush current will be dozens of times increased if connecting built-in constant current IC current-limiting LED fixtures, the driver will activate the overloaded
protection (hiccups flickering). When you order, please remark controlling the constant current LED fixture (e.g. MR16 lamp, underground light, LED wall washer, constant current LED strip, etc.), then we can prepare the special programs.
LED (Constant Voltage)
Intelligent Driver
440×218×235mm(L×W×H) 60pcs/ctn 13.4kg±5%/ctn
Carton Size
Triac/ELV
Push DIM
Triac connection
Push DIM connection
2
0~100%dimming
Short press to on/off,
long press to dim.
Push DIM
N
L
0~100%dimming
L
N
TRIAC
N
L
L1
LED+
N
L
L1
LED+
Push Dimming
LM-36-24-G1T2
LM-36-12-G1T2
www.ltech-led.com
Dimensions
Unit: mm
Wiring Diagram
Reset switch
On/off control: Short press.
Stepless dimming: Long press.
With every other long press, the brightness goes to the opposite direction.
Dimmingmemory:Thelightswillreturntoitsprevious brightnessvaluewhenshortpressonPUSHDIMbutton.
Poweronagainafterpowercut,theoutputbrightnessissubjectedtotheinputvoltageofdrivers.
Wire diameter:0.5-1.5 (20-16AWG)
Strip length:8mm-9mm
Wire diameter:0.75-1.5 (20-16AWG)
Strip length:8mm-9mm
Push DIM is invalid for DC voltage input.
Dimming interface priority: Triac first, Push DIM next.
210
43
30
170
35
157
Tension plate Remove the protective housing
Push the tension plate down to fix the electric wires. Pull the bottom left and right from the bottom to remove it.
Push the side plate outwards and
remove the tension plate by prying
it up with a tool at the same time.
Protective Housing Application Diagram
3
LM-36-12-G1T2
LM-36-24-G1T2
PF PF
THD【%】THD【%】
VO【V】VO【V】
70
70
75
75
80
80
85
85
90
90
95
95
50
50
60
60
70
70
80
80
90
90
100
100
AC230V/50Hz
AC230V/50Hz
0.80
0.80
0.85
0.85
0.90
0.90
0.95
0.95
1.00
1.00
50
50
60
60
70
70
80
80
90
90
100
100
AC230V/50Hz
AC230V/50Hz
AC230V/50Hz
AC230V/50Hz
0
8
10
12
14
16
50 60 70 80 90 100
0
8
10
12
14
16
50 60 70 80 90 100
AC230V/50Hz
0
2
4
6
8
10
12
14
3 3.15 3.3 3.45 3.6
0
4
8
12
16
20
24
1.5 1.575 1.65 1.725 1.8
AC230V/50Hz
Triac/ELV
Push DIM
LM-36-24-G1T2
LM-36-12-G1T2
www.ltech-led.com
Relationship Diagrams
IO【A】
Efficiency vs Load
Efficiency【%】
Power Factor Characteristic
Load【%】
THD vs Load Over Load Diagram
Load【%】
Load【%】
IO【A】
Efficiency vs Load
Efficiency【%】
Power Factor Characteristic
Load【%】
THD vs Load Over Load Diagram
Load【%】
Load【%】
≥15cm
≥15cm
≥15cm
≥15cm
≥15cm
Installation Precautions
Triac/ELV
Push DIM
LM-36-24-G1T2
LM-36-12-G1T2
4
Warranty Agreement
Attentions
Products shall be installed by qualified professionals.
LTECH products are non-waterproof (special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure it is mounted
in a water proof enclosure.
Good heat dissipation will extend the working life of products. Please ensure good ventilation.
Please check if the working voltage used complies with the parameter requirements of products.
The diameter of wire used must be able to load the light fixtures you connect and ensure the firm wiring.
This manual is subject to changes without further notice. Product functions depend on the goods. Please feel free to contact our
official distributors if you have any question.
Warranty exclusions below:
No any contract signed by LTECH.
Warranty labels and barcodes have been damaged.
Damage caused by natural disasters and force majeure.
Products with severe physical damage.
Beyond warranty periods.
Warranty periods from the date of delivery : 5 years.
Free repair or replacement services for quality problems are provided within warranty periods.
Any artificial damage caused by high voltage, overload, or improper operations.
1. Repair or replacement provided is the only remedy for customers. LTECH is not liable for any incidental or consequential damage
unless it is within the law.
2. LTECH has the right to amend or adjust the terms of this warranty, and release in written form shall prevail.
Before you power on products, please make sure all the wiring is correct in case of incorrect connection that causes damage to light fixtures.
If a fault occurs, please do not attempt to fix products by yourself. If you have any question, please contact your suppliers.
Brightness
0 .1 %
1%
5%
30%
40%
70%
90%
100%
10%
20%
50%
60%
80%
Frequency(Hz)
Modulation(%)
1.00%
10.00%
100.00%
0.10%
110 100 1000 100003125
Flicker Test Table
IEEE 1789
f
f
≤ 8Hz
≤ 10Hz
Limit value (%)
Exemption assessment
(High frequency exemption)
f
f
f
f
f
f
f
f
f
f
≤ 90Hz
≤ 90Hz
≤ 1250Hz
≤ 3125Hz
8Hz <
10Hz <
90Hz <
90Hz <
> 1250Hz
> 3125Hz
0.2
0.1
0.025 ×
0.01 ×
0.08 ×
(0.08/2.5) ×
Limit Value of Modulation in Low Risk Areas
Waveform frequency of Optical output
Exemption assessment
Limit Value of Modulation in No Effect Areas
Waveform frequency of Optical output Limit value (%)
Modulation Area
High Frequency Exemption Area
Marks in the right chart are tested results of different current levels.
The output frequency is 0Hz in 100% brightness and its corresponding
modulation is 0%, which could not be shown in the right chart.
Update Log
Version Update Content
Updated Time
A0 Original version.
2021.04.12
Updated by
Xu Shujun
A1 Updated the silkscreen on the product.
2021.12.27 Xu Shujun
Update Time: 27/12/2021_A1
www.ltech-led.com

This manual suits for next models

1

Popular Power Supply manuals by other brands

TEXIO PDS20-10A instruction manual

TEXIO

TEXIO PDS20-10A instruction manual

Eaton CROUSE-HINDS MTL MA3115 Series instruction sheet

Eaton

Eaton CROUSE-HINDS MTL MA3115 Series instruction sheet

Elster Instromet FE260 Operating Manual and Installation Instructions

Elster Instromet

Elster Instromet FE260 Operating Manual and Installation Instructions

B+K precision 9130 instruction manual

B+K precision

B+K precision 9130 instruction manual

Miller EnPak A28 GBW owner's manual

Miller

Miller EnPak A28 GBW owner's manual

Intel Entry Redundant Power 2U ERP2U Design guide

Intel

Intel Entry Redundant Power 2U ERP2U Design guide

MAKELSAN AG-SD-36 user manual

MAKELSAN

MAKELSAN AG-SD-36 user manual

Monacor PSS-3800SV operating instructions

Monacor

Monacor PSS-3800SV operating instructions

HP StorageWorks 2312 Replacement instructions

HP

HP StorageWorks 2312 Replacement instructions

Vahle VKS10 Mounting instructions - Maintenance

Vahle

Vahle VKS10 Mounting instructions - Maintenance

Xantrex XDL 35-5 operating manual

Xantrex

Xantrex XDL 35-5 operating manual

Altronix LPS3AC installation guide

Altronix

Altronix LPS3AC installation guide

Rohde & Schwarz TS-PSU12 user manual

Rohde & Schwarz

Rohde & Schwarz TS-PSU12 user manual

First Choice PSEL-3000-2 troubleshooting guide

First Choice

First Choice PSEL-3000-2 troubleshooting guide

Overland Storage NEO 2000e quick start guide

Overland Storage

Overland Storage NEO 2000e quick start guide

Scientech Technologies Scientech 4077A Product tutorial

Scientech Technologies

Scientech Technologies Scientech 4077A Product tutorial

Axis T8008 PS12 installation guide

Axis

Axis T8008 PS12 installation guide

SATA AE5723 user manual

SATA

SATA AE5723 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.