Troubleshooting
?
Problem Possible Cause Solutions
LEDs stop working
LEDs flash on and off
The power line is improperly connected.
The power plug is loose.
The LED driver malfunctions.
The LED chip is damaged.
The output of the driver is abnormal.
The LED chip breaks down.
Reconnect the power cable.
Firmly plug the power in.
Replace with new driver.
Replace with new LEDs.
Replace with new driver.
Replace with new LED chip.
5 years warranty for original purchaser of LED product that is identified on seller's invoice
reflecting its original purchase (the "Product").
1. In order to make a warranty claim, you must notify seller in writing within sixty(60) days after your
discovery of the defect, provide proof of purchase such as the invoice and comply with seller's other
warranty requirements. Upon receiving that notice, to ascertain why fixtures stop working, evidences
would be needed for seller's QC Team to analyze. Seller may require you to promptly return the Product
to Seller when necessary, freight prepaid.
2. The determination of whether the Product is defective shall be made by Seller in its sole discretion with
consideration given to the over all performance of the Product.
3. If seller determines the Product is defective, Seller will elect, in its sole discretion, repair the Product
or replace the Product. Seller reserves the right to utilize new, reconditioned, refurbished, repaired or
remanufactured products or parts in the warranty repair or replacement process. Such products and
parts will be comparable in function and performance to an original product or part, as determined by
Seller in its sole discretion, and warranted for the remainder of the original warranty period. However,
cost of labor and equipment to remove the defective product and install a repaired or a replacement
Product at the end-user facility are excluded. Supplier's aggregate liability with respect to a defective
product shall in any event be limited to the money paid to buyer for that defective product.
The following circumstances will not be warranted:
1. Damage caused by force majeure such as war, riots, sabotage, cyclones, earthquakes, tidal waves,
flooding, lighting strikes, explosions, fire, flood, etc.
2. Damage caused by user's improper delivery, defects caused by wrong operation, wrong treatment
and destruction of machinery.
3. Dismantling or modification or improper maintenance or repairing of the products without the
supplier's authorization.
4. Damage caused by buyer or installer using bad quality cable or other mismatching electronic parts.
5. This warranty is invalid if the product is not used for the purpose for which is originally designed. Any
disputes occurred shall be applied to the laws and regulations of P.R.C.
The seller has the sole right to interpret and amend the above articles.
3.
AC
DIMMABLE
22
20
4.
Waterproof Connector should be tightened when you connect input wire.
5.
INPUT
(L, N, )
+
-
+
-
+
-
+
-
INPUT
(DIM+,
DIM-)
DRIVER
(DC+,
DC-)
DRIVER
(DIM+,
DIM-)
PCB
(DC+,
DC-)
DRIVER(L, N , )
Wire diameter:
7-12mm
Wire diameter:
5-10mm
Version: 01
SPD (L, N, )
HEAT SINK( )
Installation Instructions
Physical Dimensions
o
90
o
90
Product Specifications 40W 120W 240W
Input Voltage
Power Frequency
Outlook Dimensions
Luminaire Net Weight
(±0.3kg / ±0.66Lbs)
Working Temperature
Storing Temperature
AC100-240V / AC100-277V / AC200-240V / AC277-480V
50 / 60Hz
o o o o
-30 C to +45 C (-22 F to +113 F)
o o o o
-40 C to +70 C (-40 F to +158 F)
413×366×83mm
(16.26"×14.41"×3.27")
4.3kg
(9.48Lbs)
With aluminum heat sink, high-brightness SMD chip, high-effciency constant current and voltage power
driver, LED Flood light is designed for applications in large industrial areas like airports, big docks,
squares, stadiums, etc.
Technical Parameters
We appreciate your purchase!
Please read the instruction manual before installation and keep it for future reference.
Reminder
Application
Warning
1. To avoid damage, falling, electric shock or fire, please do not modify the lamp or replace accessories without
confirming with the supplier first.
2. Please authorize only qualified personnel to install the lamp and ensure they follow the instructionmanual.
Any improper installation might cause falling, electric shock, fire, or other injury, damage or hazard.
3. Please disconnect power before installation or any maintenance of the lamp.
4. Please disconnect power if it begins to smoke or emit odors, since fire or electric shock may occur. Ask
qualified person to inspect and maintain the luminaire.
5. Please do not dismantle the lamp without the supplier’s authorization.
6. Please do not touch the power supply when the lamp is operating.
7. If the external flexible cable or cord of the luminaire is damaged, it should only be replaced by the supplier,
a service agent or qualified person.
8. Terminal block not included. Instal lation may require advice from a qualified person.
9. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent
or a similar qualified person.
10. Only to be installed outside arms reach.
11. For use in environments where an accumulation of non-conductive dust on the luminaire may be expected.
12.Mounting heights of light s not higher than 20m.
Caution risk of electric shock
200W
180W150W
80W 100W
359×308×82mm
(14.13"×12.13"×3.23")
462×452×87mm
(18.19"×17.8"×3.43")
40W/60W/80W
100W/120W/150W
180W/200W/240W
45mm(1.77")
87mm
(3.43")
452mm(17.8")
430mm(16.93")
462mm(18.19")
418mm(16.46")
100mm
(3.94")
240mm(9.45")
42mm(1.65")
83mm
(3.27")
413mm(16.26")
334mm(13.15")
366mm(14.41")
325mm(12.8")
60mm
(2.36")
160mm(6.3")
82mm
(3.23")
359mm(14.13")
40mm(1.57") 276mm(10.87")
308mm(12.13")
265mm(10.43")
11mm(0.43")
25mm(0.98")
55mm
(2.17")
135mm(5.31")
∅11mm(0.43")
60W
4.5kg
(9.92Lbs)
4.6kg
(10.14Lbs)
6.3kg
(13.89Lbs)
6.5kg
(14.33Lbs)
6.8kg
(14.99Lbs)
8.4kg
(18.52Lbs)
8.6kg
(18.96Lbs)
8.9kg
(19.62Lbs)
Bracket mounting (With input line)
Bracket mounting (Without input line)
L
N
GND
brown
blue
yellow/green
Dimmable
DIM-white
blue
blue
brown
black
white
green
DIM+
gray black
purple white
1.
2.
o o
120 ±5
The cover tempered glass should be
paid attention to avoid collision with
ground when we open the buckle.
The buckle should be opened
by flat blade screwdriver.
11mm(0.43")
∅11mm(0.43")
40mm(1.57")
11mm(0.43")
40mm(1.57") ∅11mm(0.43")

This manual suits for next models

8

Popular Floodlight manuals by other brands

Blizzard Lighting SkyBox 5 manual

Blizzard Lighting

Blizzard Lighting SkyBox 5 manual

Jula anslut 427-618 User instructions

Jula

Jula anslut 427-618 User instructions

Show Tec Shark Scan One manual

Show Tec

Show Tec Shark Scan One manual

Eterna FL157BPC Safety and installation instructions

Eterna

Eterna FL157BPC Safety and installation instructions

Cooper Lighting Solutions Halo ALP90LSFSUNVDGY instructions

Cooper Lighting Solutions

Cooper Lighting Solutions Halo ALP90LSFSUNVDGY instructions

Ocean Technologies 7000101112 quick start guide

Ocean Technologies

Ocean Technologies 7000101112 quick start guide

DTS SCENA COMPACT HALOGEN 300W user manual

DTS

DTS SCENA COMPACT HALOGEN 300W user manual

BEGA 77 584 Instructions for use

BEGA

BEGA 77 584 Instructions for use

Cooper Lighting MS185DW instruction manual

Cooper Lighting

Cooper Lighting MS185DW instruction manual

Lithonia Lighting OLF 2SH 40K 120 installation instructions

Lithonia Lighting

Lithonia Lighting OLF 2SH 40K 120 installation instructions

KingShield LEDFLPIR10E installation instructions

KingShield

KingShield LEDFLPIR10E installation instructions

thomann STAIRVILLE xBrick Quad 16x8W RGBW user manual

thomann

thomann STAIRVILLE xBrick Quad 16x8W RGBW user manual

Chauvet LED PAR 38-18UVB user manual

Chauvet

Chauvet LED PAR 38-18UVB user manual

Red Arrow FLSMD50Y-1 installation instructions

Red Arrow

Red Arrow FLSMD50Y-1 installation instructions

C-LITE C-FL-A-LCF Series installation instructions

C-LITE

C-LITE C-FL-A-LCF Series installation instructions

EuroLite TB-5 DMX-Barrel-Effect user manual

EuroLite

EuroLite TB-5 DMX-Barrel-Effect user manual

Deluce Lighting DLPAN10WBLKDL Fitting instructions

Deluce Lighting

Deluce Lighting DLPAN10WBLKDL Fitting instructions

Scanic LED Double Eye Moonflower DMX instruction manual

Scanic

Scanic LED Double Eye Moonflower DMX instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.