ESR.4 Four channel wireless ON/OFF receiver Specification.
RF input 433.92Mhz 10m/w
Antenna connection Screw terminal
Antenna 433Mhz 1/4 wave (included)
RF range 100—200m line of sight
Learning capacity. 16 devices per zone. 64 in all.
Number of channels 4
Supply voltage 230 volts 50Hz
Relay output voltages 230 volts 50Hz
Relay contact ratings 1kw resistive. (Halogen) 100 watts for LED lighting.
Maximum switch rating 2KW total shared by 4 relays (8 amps)
Enclosure ABS L190 W140 H90mm
IP rating 65
Luminite Easyswitch wireless product range
Transmitters:
PIR detector Wide angle 15m x 90 deg ESD.1
PIR detector Long range 40m x 1 deg ESD.2
PIR detector Pet ally 12 m x 90 deg ESD.3
Key fob 1 button ESF.1
Key fob 2 button ESF.2
Key fob 4 button ESF.4
Wall switch transmitter. Connects to up to 4 switches. EST.1
HVAC transmitter for heating systems. 4 inputs. EST4HVAC
Receivers:
Single zone ON/OFF receiver. ESR.1
Four zone ON/OFF receiver. ESR.4
Four zone ON/OFF receiver with ESF4 key fob. ESR4x4
Plug adaptor. ESA.1
Plug in bleeper. ESB.1
Technical help: Tel: 0208 368 7887
ESR.4 & ESR4X4
4 channel
receiver
Installation
Handbook
Type: ESR.4 & ESR4X4 Issue 4.
EasySwitch Wireless
Detection and Automation System
Copyright 2016 Luminite Electronics Ltd
All rights reserved. Unauthorised duplication of this handbook by any means
mechanical or electrical, is strictly prohibited without the express written permission of
Luminite Electronics Ltd.
Luminite Electronics Ltd acknowledge all registered trademarks
Luminite Electronics Ltd reserve the right to make changes to this handbook and to its
products without prior notice in order to improve design or performance characteristics.
PRE-INSTALLATION NOTES
Unpacking.
On receipt, inspect the package and contents for signs of damage. If damage has oc-
curred, advise the carrier and/or suppliers immediately. Inspect the contents to confirm
that all items are present and undamaged. If any items are missing or damaged, contact
the supplier immediately. It is advisable that the original carton is retained as this forms
the safest transport container in the event that a unit has to be returned for any reason.
Servicing.
This unit should not require general servicing. Any repair work should only be
undertaken by Luminite Electronics Ltd.
Moisture.
Do not expose the internal electronics of this unit to moisture i.e. take care during
installation not to allow rain or damp into the product. When the product is sealed it is
water resistant to IP66.
Box Contents.
ESR.4 1 x Easyswitch ESR.4 receiver switcher
ESR4X4 1 x Easyswitch ESR.4 receiver switcher and 1 x ESF.4 four button fob.
ESR.4 & ESR4X4 four channel receiver Installation Handbook
ESR.4 & ESR4X4 four channel receiver Installation Handbook Page 5.
A different MODE may be selected for each relay if required.
SINGLE WAY MODE.
Use this mode when one switch is used or when more than one receiver is to operate
from the same transmitter. This will prevent them from getting out of step.
TWO WAY mode.
Use this mode when more than one transmitter is to work the same channel on the
ESR.4 receiver. Each transmission from any of the learned transmitters will operate the
relay and counter the previous command.
MIMIC mode.
In this mode the relay will operate only as long as the transmission. It is normally used
with the key fobs to provide a momentary output
Do not use this mode with a PIR detector unless a momentary contact change is
required.
LEARNING THE TRANSMITTERS.
Each channel can learn up to 16 mixed transmitters.
The learn buttons and LED indicator are located as shown.
TO LEARN A KEY FOB. (ESF)
momentarily press the appropriate button on the ESR.4 until the red
LEARN led lights. Now press the appropriate button on the key fob.
The LEARN led on the ESR.4 will flash three times indicating that the
transmitter has been learnt.
Do the same for each additional fob that is to be learnt.
TO LEARN A WALL SWITCH. (EST)
momentarily press the appropriate button on the ESR.4 until the red LEARN led lights.
Now press the appropriate switch on the wall plate. The LEARN led on the ESR.4 will
flash three times indicating that the transmitter has been learnt.
Do the same for each additional switch that is to be learnt.
TO LEARN A PIR DETECTOR. (ESD)
momentarily press the appropriate button on the ESR.4 until the red LEARN led lights.
Now connect a 9 volt battery to the PIR detector. The LEARN led on the ESR.4 will flash
three times indicating that the transmitter has been learnt.
Do the same for each additional PIR that is to be learnt.
TO CLEAR THE MEMORY.
Each channel can be cleared individually as follows.
Press and hold the appropriate LEARN button for up to ten seconds or until the LEARN
led goes out. This will have flushed the entire memory for that channel.
Re-learning can begin again in the usual way.
1 2
3 4
LEARN
ESR.4 & ESR4X4 four channel receiver Installation Handbook Page 4.
TYPES OF MODES: SINGLE way mode. TWO WAY mode. MIMIC mode.
No jumper
for SINGLE
way mode
Jumper top two
pins for TWO
WAY mode
Jumper bottom
two pins for
MIMIC mode
POSITIONING & WIRING.
IMPORTANT: All wiring must be carried out by a qualified electrician in
accordance with IEE and part P regulations.
This product is IP65 rated and may be fitted outdoors. Choose a suitable position for
easy wiring but make sure that the aerial is clear of obstructions and metal objects.
The cable glands must face down and the aerial skywards.
Remove the circuit board from the enclosure by first unscrewing the aerial and ground
terminals and removing the aerial cable. Now unscrew the three fixing screws as shown
in Fig 1 and remove the whole circuit board. Fix the enclosure using countersunk
screws through the screw cups on the base of the enclosure. Seal these screws with a
suitable waterproof sealant to maintain the IP rating of the enclosure. Re-fit the board
and connect the aerial cable making sure that the screen connects to the ground terminal
as shown in Fig 2.
This product is powered from mains voltage 230V 50Hz and can switch up to a maximum
of 2KW resistive shared over four relays. Each relay has a switched 230V Live output
and has a maximum 1KW resistive switch capacity. EG: If two relays are switching 1KW
each then the remaining relays cannot be used. Alternatively all four relays can be used
up to a maximum of 500W each.
The mains supply should be from a fused spur or consumer unit and be fused correctly
according to the load. Do not fuse above 8amps.
Pass a round 1.5mm flex through the left hand gland and tighten to provide cable
restraint and a waterproof seal. Maximum outside diameter 8mm.
Connect the 230 volts LIVE and NEUTRAL to the MAINS IN terminal as shown.
For each channel that is to be used, slacken one of the glands and remove the bung to
enable round 1.5mm cable to be passed through. Tighten the gland to provide a
waterproof seal and cable restraint. Connect the cable to one of the four channel
outputs as shown. Ensure that the load does not exceed the maximum rating.
The EARTH block is common and purely used as a convenient means of connecting all
the earths.
MODE SETTING.
INDEX page
ESR.4 & ESR4X4 four channel receiver Installation Handbook Page 1.
Introduction. 2
Aerial connection. 3
Positioning & Wiring. Mode setting 4 & 5
Learning transmitters and clearing memory 5
Introduction
The ESR.4 receiver is a mains powered mains switching receiver and works in
conjunction with all other products in the easyswitch range.
There are four relays each capable of switching 230 volts 1kw resistive load or 100
watts LED.
This product has a maximum power handling of 8 amps resistive shared over four
relays.
Each relay operates independently and is described as a CHANNEL.
The ESR.4 can learn up to 16 mixed transmitters for each channel.
The memory is non volatile and will not be lost if the power fails.
The ESR.4 will operate up to a distance of up to 200 metres line of sight from any of
the easyswitch transmitters.
TYPES OF TRANSMITTERS:
EST.1 Wireless wall switch. One to three gang.
ESF.1, 2 & 4 Wireless key fob. One, two or four button versions.
ESD.1, 2 & 3 Wireless PIR detector. Choice of three detection patterns.
This example shows one PIR per zone but with a combination of key fobs which will
over-ride the PIR’s. Two of the PIR’s are shown also operating a remote bleeper.
In all. This product will learn 64 devices in all.
ESR.4 & ESR4X4 four channel receiver Installation Handbook Page 2.
PIR PIR PIR PIR
Bleeper
CHANNEL 1
2 button
Key fob
4 button
Key fob
1 button
Key fob
EXAMPLE:
Fig 1
CHANNEL 2 CHANNEL 3 CHANNEL 4
ESR.4 & ESR4X4 four channel receiver Installation Handbook Page 3.
EARTHS
1 2
3 4
Remove jumper for single mode
Two way
Mimic
LEARN
1 2 3 4
MAINS
IN
230V
CHANNEL
1
230V
CHANNEL
2
230V
CHANNEL
3
230V
CHANNEL
4
230V
LIVE IN
NEUTRAL
LIVE OUT
NEUTRAL
LIVE OUT
NEUTRAL
LIVE OUT
NEUTRAL
LIVE OUT
NEUTRAL
AERIAL
GROUND
AERIAL CONNECTION:
This product works well using the aerial supplied however there are other types of aerial
available for longer reception range if required. Please contact your dealer for
information.
Unscrew the dome nut on the top of the enclosure and fit the wire aerial supplied.
This aerial must be vertical and point skywards.
Keep the aerial away from large metal objects such as pipes, tanks and even electrical
cables.
If an alternative aerial is required, remove the coaxial cable from the Ground and aerial
terminals as shown and replace with the new aerial cable.
IMPRTANT: Make sure that the removed cable cannot short out on the circuit board as
this will result in serious injury or death through electric shock.
1 2 3 4
LAMP LOAD
MAX 2KW
230V
LAMP LOAD
MAX 2KW
230V
LAMP LOAD
MAX 2KW
230V
LAMP LOAD
MAX 2KW
230V
MAINS IN
8 AMP MAX
Fig 2
FIXING SCREW.
FIXING SCREW.
FIXING
SCREW.
Screen of
aerial cable

This manual suits for next models

1

Other Luminite Receiver manuals

Luminite Easyswitch ESR-1v2 User manual

Luminite

Luminite Easyswitch ESR-1v2 User manual

Popular Receiver manuals by other brands

mcmurdo NAV6 user manual

mcmurdo

mcmurdo NAV6 user manual

Sony STR-D1011 operating instructions

Sony

Sony STR-D1011 operating instructions

Aiwa FR-CD1500 operating instructions

Aiwa

Aiwa FR-CD1500 operating instructions

Rittal SV 9677.900 Assembly instructions

Rittal

Rittal SV 9677.900 Assembly instructions

Onkyo HT-R510 Service manual

Onkyo

Onkyo HT-R510 Service manual

Sony STR-DB900 installation guide

Sony

Sony STR-DB900 installation guide

Trio Kenwood 9R-59DS operating instructions

Trio Kenwood

Trio Kenwood 9R-59DS operating instructions

DAPAudio EDGE EHS-1 manual

DAPAudio

DAPAudio EDGE EHS-1 manual

Carlson NR3 user manual

Carlson

Carlson NR3 user manual

KLAU Geomatics KlauPPK 7700 Series user manual

KLAU Geomatics

KLAU Geomatics KlauPPK 7700 Series user manual

X10 VR36A owner's manual

X10

X10 VR36A owner's manual

Javad DELTAGNSS Receiver Operator's manual

Javad

Javad DELTAGNSS Receiver Operator's manual

JVC Audio/Video Control Receiver RX-5060S instructions

JVC

JVC Audio/Video Control Receiver RX-5060S instructions

Audio Ltd. a10-rack user guide

Audio Ltd.

Audio Ltd. a10-rack user guide

Harman Kardon AVR 145 Brochure & specs

Harman Kardon

Harman Kardon AVR 145 Brochure & specs

Zonge GDP-32II manual

Zonge

Zonge GDP-32II manual

Kenwood KMM-DAB403 manual

Kenwood

Kenwood KMM-DAB403 manual

eGPS Solutions 20TL quick start guide

eGPS Solutions

eGPS Solutions 20TL quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.