E247 02.20
Description
Installation
Technical data
Supply voltage 100-240 V AC 50 Hz
Unit voltage 12 V DC SELV
Dimensions in mm
(W x H x D) 155 x 97 x 20
Dimensions of box in mm
(W x H x D) 143 x 70 x 75
Display E-Ink technology
Protection type IP22, CE
Control unit for controlling 12 V based ventilation units (e.g. e², e²mini, ego, RA
15-60) or 230 V based ventilation units with additional module (e.g. Silvento, AB
30/60) for domestic ventilation
Incl. deep electronic box for horizontal installation in cavity wall constructions
and solid walls
Dimensions UP box (L x W x D) 143 x 70 x 75 mm
Recommended height: 1.4 - 1.6 m
Order No. 039 946
Note
Products and illustrations may be subject to slight variation. Due to continuous pro-
duct development and/or several suppliers e.g. for raw materials, colours, among
other things, may vary slightly (not for visible parts) or be shown differently in bro-
chures.
Only one type of ventilation unit can be controlled via each output.
The installation is carried out under plaster using the supplied electronics / cavity
wall box. The recommended installation height is approximately 1.50 m from the
finished floor (OKFF = top edge of finished floor). A commercially available NYM
cable with 3 x 1.5 mm² is sufficient for the supply voltage of 100-240 V AC.
More detailed information on the installation and electrical connection can be found
in the installation and commissioning manual.
The operating manual is available on www.lunos.de and must be passed on to the
user (tenant, owner, property manager, etc.) after completion of the installation.
Please observe the installation manual and have the electrical connection of the
fan made in a professional manner.