2. SPECIFICATIONS
2-1 General Specifications
Display 60 mm x 39 mm large LCD display
Measurement DCV, ACV, DCA, ACA, Resistance,Diode,
Continuity beeper,Capacitance,Inductance,
Datalogger Auto 2 seconds to 3600 seconds
Sampling Time
Setting range
Manual Push the data logger button
once will save data one time.
@ Set the sampling time to 0 seconds.
Data error no.
≦
0.1% no. of total saved data typically.
micro SD card 4 GB to 32 GB
Capacity
A/D counts no. 6000 counts.
Range selection Auto range with manual range selecting.
Special function
Relative measurement, Data hold,
Data hold To freeze the display reading on the LCD display.
Power On/Off Auto power off or manual power off.
management @ Details please refer page 7
Memory recall
Records Maximum & Minimum readings with recall.
Relative measurement To offset the measurement value.
V/A/Hz button When execute the voltage or current function
also can measure the frequency of signal.
Data output RS 232 PC serial interface, photo couple.
Polarity
Automatic Switching, " - " indicates negative polarity.
Zero adjustment Automatic.
Sampling time Approx. 0.5 to 1 second.
of display
Operating 0
℃
to 50
℃
(32
℉
to 122
℉
),
Temp. & humidity Max. 80% RH.
Power supply 9 V ( 006P, MIN1604 )
DC 9V adapter input
*AC/DC Power adapter is optional.
Power Normal operation (w/o Micro SD card save data).
consumption Approx. DC 5.5 mA
When Micro SD card save the data
Approx. DC 25 mA.