WARRANTY
All fiber optic transmission systems, products and accessories
manufactured by Liteway, Inc. and it’s subsidiaries are fully tested prior
to shipment and are warranted against defective materials and
workmanship for a period of five full years from the date of the original
shipment. Should a problem occur, a Return Material Authorization
Number (RMA) must be obtained from Liteway Inc. at (516) 931-2800
and the item returned to Liteway, Inc. 166 Haverford Road, Hicksville,
NY 11801, USA, prepaid. Liteway Inc. will then, at its option repair or
replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the cost
of the defective item only. No contingent liabilities of any kind are either
assumed or implied.
Any items returned to Liteway, Inc. that have been misused, abused,
damaged, modified, connected or adjusted in any way contrary to the
instructions furnished by Liteway, Inc. or repaired by unauthorized
personnel will not be covered by this warranty. Any non-warranty
repairs required will be quoted at the current rate for such services.
Important Notices
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All -7,-8, and -9 Models use laser diodes. These solid-state laser diodes
are located in the optical ports of these units. Laser diodes produce
invisible radiation that may be harmful to human eyes. Never look
directly into the optical port of any fiber optic unit designed to operate
with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or
accessories for use in critical life support systems or applications of any
kind.
© Copyright 2018 Liteway, Inc. 124968 Rev E
OPERATING INSTRUCTIONS
Fiber Optic IRIG
Signal Distribution
Model IRGP-1501
The IRGP-1501 is an optical repeater that is used to implement a
drop-and-repeat network for IRIG A through E signals.
Technical Specifications
Signal Bandwidth 100 Hz to 500 KHz
Out Impedance 50 ohms
Out Signal Level 3 volt peak to peak, (5 mA)
Signal/Noise Ratio 60 dB/min (ref 1Vpp)
Linearity & THD 3% max
Operating Wavelength 850 (-1), 1310 (-3,-7), 1550 (-9)
Optical Output -15 dBm typical
Optical Loss Budget 0 – 12 dB
Fibers Accommodated 1 multimode (-1,-3), 1 single-mode (-7,-9)
MTBF 100,000 Hours (MIL-HDBK-217)
Temperature Range -35º to +75ºC
Humidity <95% non condensing
Power Requirements 11-24 VAC/DC @ 190 mA
Physical Size (mm) 5.0”(127)L x 3.0”(76)D x 1.0” (25.4)W
All specifications measured with 1Km of 62.5u multimode fiber.
All specifications are subject to change without prior notice.
!
Installation Instructions
The diagram below shows the typical installation IRIG system which
utilizes the IRGM-1504 and IRGP-1501 for IRIG distribution.
Typical Fiber Optic IRIG System
Fiber Optic Cable
IRGP-1501IRGM-1504
Master
IRIG
Source
(50O)
IRGR-1501
IRIG
Output
IRIG Output
IRIG
Output
IRGR-1501
Fiber
Optic Cable
Fiber
Optic Cable
In the above diagram only two optical outputs of the IRGM-1504 are
utilized. The IRGM-1504 however provided four optical outputs
Adjustment of the IRGP-1501
The IRGP-1501 IRIG repeater has a fiber optic receiver that can be
adjusted to compensate for the unique fiber losses of your
installation. The range of the receiver level control is adequate to
allow the full 0 - 13dB optical path loss range to be accommodated. .
When using the IRGP-1501 in a daisy chained linear distribution
system the front panel receiver Level adjustment must be set for a
three volt peak to peak IRIG output so that the internal optical
transmitter will send the proper level signal to the next IRGP-1501
repeater in line. If this is not done to each of the IRGP-1501 units in
line the signal may be distorted as the number of units is increased.
124968 Rev E
Power Terminal Block Connections
Pin Function
1 Alarm output for use with optional Alarm Sensing Unit
ALM-1000. No other connections should be made to
this terminal
2 +11 to 24 DC or AC Volts input
3 AC or DC return (Common to Housing)
Be certain to check all connections, settings and voltages before
applying power
Indicator Lights
Indicator Lights when
Pwr Proper power is present.
Alrm The loss of signal alarm is activated and there is
no IRIG signal present to transmit.
Rx A data signal is being received.
Tx A data signal is being retransmitted
The Alarm switch is used to turn the alarm function ON and OFF.

Popular Repeater manuals by other brands

NHRC NHRC-4/M2 Installation and setup guide

NHRC

NHRC NHRC-4/M2 Installation and setup guide

Dekolink DEKO2408 product manual

Dekolink

Dekolink DEKO2408 product manual

Andover Controls InfiLink 200 installation guide

Andover Controls

Andover Controls InfiLink 200 installation guide

TP-Link TL-WA850RE Quick installation guide

TP-Link

TP-Link TL-WA850RE Quick installation guide

Vertex Standard VXR-9000 Series Specifications

Vertex Standard

Vertex Standard VXR-9000 Series Specifications

Kenwood NEXEDGE NXR-800 Service manual

Kenwood

Kenwood NEXEDGE NXR-800 Service manual

COMBA SR-2110 Equipment manual

COMBA

COMBA SR-2110 Equipment manual

ESD CAN-Repeater-I Hardware manual

ESD

ESD CAN-Repeater-I Hardware manual

Ltech LT-3060-8A instructions

Ltech

Ltech LT-3060-8A instructions

Hawking HDW2R1 user manual

Hawking

Hawking HDW2R1 user manual

MyAmplifiers ma-130 installation guide

MyAmplifiers

MyAmplifiers ma-130 installation guide

Kenwood NXR-800H Service manual

Kenwood

Kenwood NXR-800H Service manual

NEXTIVITY Cel-Fi QUATRA Product information

NEXTIVITY

NEXTIVITY Cel-Fi QUATRA Product information

Ten-Tronics A-1410K user guide

Ten-Tronics

Ten-Tronics A-1410K user guide

Gefen DVI-141HD manual

Gefen

Gefen DVI-141HD manual

zBoost ZB545M user manual

zBoost

zBoost ZB545M user manual

Dräger Polytron 6100 EC WL Instructions for use

Dräger

Dräger Polytron 6100 EC WL Instructions for use

Sengled element Z01-hub quick start guide

Sengled

Sengled element Z01-hub quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.