In the box:
2x wireless smoke alarms, 2x 9 V batteries, 6x AA batteries, 2x mounting brackets, 2x
screws, 2x plugs, manual.
Placement
Smoke alarms should be installed on all oors of the home and placed adjacent to
sleeping areas as you are most vulnerable to smoke and re when you are asleep. If you
are charging electric devices in the bedroom it is recommended to install a smoke alarm
in the bedroom. It is also recommended to install a smoke alarm adjacent to the kitchen
area, but avoid placing it inside the kitchen or the bathroom.
When using multiple smoke alarms in your home the distance between them should not
be greater than 12 meters. A smoke alarm can cover an area of maximum 60 m.
(source: www.brandskyddsforeningen.se →“I hemmet” →“Brandvarnare”.
Do not install smoke alarms in the following areas
• In places such as kitchens or near replaces and hot water heaters where the
occurrence of smoke is normal. Use specialized smoke alarms for these areas.
• In areas with high humidity, like bathrooms or areas near dishwashers
or washing machines. Install at least 3 m away from these areas.
• Near air returns, heating or cooling supply vents. Install at least 2 m away from
these utilities as the circulating air can blow smoke away from the detector.
• In rooms where temperatures may fall below 0 °C or rise above 40 °C.
• In very dusty or dirty areas, like a garage. Dirt particles
may interfere with smoke alarm operation.
ENGLISH ENGLISH
If the ceiling is slanting, the alarm needs to be installed at least 50 cm away (100 cm
recommended) from the highest ceiling point in the room.
Optimal placement
Since smoke and heat spread horizontally after rising
to the ceiling, installing the alarm middle of the ceiling
is optimal.If you cannot install the alarm in the middle
of the ceiling, the distance from the upper wall corner
should be at least 50 cm.
Note! If you cannot install the smoke alarm in the ceiling it can be installed on a wall,
but it will take longer for the smoke alarm to react to potential danger. Placement needs
to be 15 cm from the ceiling.
(source: www.brandskyddsforeningen.se →"I hemmet" →"Brandvarnare")
Batteries and mounting
Separate the bracket from the smoke alarm by twisting it. Hold the bracket against the
surface where you want to mount the alarm and use a pencil to mark 2 drill points. Drill 2
holes (Ø5 mm), insert the plastic plugs into the holes and attach the bracket by using the
included screws.
Insert the batteries into the smoke alarm’s battery compartments, mind the polarity. The
9 V battery is used to power the smoke alarm function, while the AA batteries are for the
wireless connection between multiple smoke alarms.
Note! When inserting the batteries, make sure to press down the red safety latches and
keep them depressed using the batteries. Both red safety latches need to be pressed
down by the batteries for the smoke alarm to attach to the mounting plate.
Test the smoke alarm before attaching it to the mounting bracket. Press and hold the
TEST button (2) on the smoke alarm for up to 5 seconds. The indactor lights (1, 4) turn on
and the siren sounds.
Twist the smoke alarm into place while pressing it against the bracket.
The alarm indicator (1) ashes every 40 seconds to indicate the smoke alarm is turned
on. The alarm emits a short sound and the LED indicator lights up every 60 seconds to
indicate that the battery level is running low.