Lykketronic Flex Counter Standard User manual

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 1
Instruction manual
Flex Counter Standard
System
Lykketronic Flex Counter Standard
Part number
Serie number
Installed by
Installation date

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 2
TABLE OF CONTENTS
1. OVERVIEW OF INCLUDED FUNCTIONS....................................................................3
1.1 SPEED INDICATOR (F.1)....................................................................................................................................................3
1.2 AREA COUNTER (F.2) .......................................................................................................................................................4
1.3 UNIT COUNTER (F.3).........................................................................................................................................................4
1.4 REVOLUTION COUNTER (F.4)............................................................................................................................................5
1.5 WORKING HOURS (F.5).....................................................................................................................................................5
1.6 WRAP COUNTER (F.6).......................................................................................................................................................5
2. OPERATION GUIDE................................................................................................................................6
2.1 OVERVIEW........................................................................................................................................................................6
2.2 CHANGE OF ACTIVE FUNCTION .........................................................................................................................................7
2.3 CHANGING AND RESETTING VALUES.................................................................................................................................7
2.4 TURNING THE FLEX COUNTER ON AND OFF - STOP-MODE................................................................................................9
2.5 POWER SUPPLY.................................................................................................................................................................9
2.6 STORING DATA – THE MEMORY OF THE FLEX COUNTER ..................................................................................................9
3. INSTALLING THE SENSOR AND MAGNET...........................................................10
4. TECHNICAL DATA.................................................................................................................................10
5. FINAL REMARKS.....................................................................................................................................11

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 3
1. Overview of included functions
The Flex Counter can be used for multiple purposes within the agricultural sector. The Flex Counter
can measure the following:
F.1 – Speed indicator
F.2 – Area counter
F.3 – Unit counter
F.4 – Revolution counter
F.5 – Working hours
F.6 – Wrap counter
Only one of the functions stated above can be measured at the time.
The individual functions and their characteristics are described below.
Furthermore - please refer to “Installing the sensor and magnet”, where the use of the sensor in
connection with the different functions of the Flex Counter is described.
1.1 Speed indicator (F.1)
To calculate speed, the computer requires to be programmed with the value of the wheel circumference
from which the wheel sensor receives its impulses. It is highly recommendable to mount the wheel
sensor on a trailing wheel. However, on four-wheel drives the rear wheel is recommended.
A distance equal to ten (10) wheel revolutions is driven. This distance is measured and divided by ten.
The resulting factor is the wheel circumference.
The condition of the soil affects the accuracy of the circumference. It is therefore an advantage to
generate a circumference for hard, soft and very soft soil, so that the right factor is available for the
various conditions.
By installing more magnets on the wheel, a faster registration of the actual speed changes (e.g.
when starting to drive) can be obtained. In this case it is important that the magnets are placed
with equal distance between them and that the number of magnets applied divides the
circumference.
Please notice that the Flex Counter require a pulse signal from the sensor every 5 seconds., otherwise
the speed is displayed as 0 km/h.
The circumference is to be entered in centimeters. The table right below shows how different
circumferences are displayed, and how the comma must be positioned.

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 4
Intervals for indicating the wheel circumference
Interval Display example
< 100 cm 87,25
=> 100 cm 315,8
1.2 Area counter (F.2)
In order to use the area counter, the wheel circumference and the working width of the machine used
must first be entered.
Regarding the wheel circumference - please refer to the previous chapter “Speed indicator (F.1)” and
chapter 2.3. “Changing and resetting values”, that gives instructions on how to enter the circumference.
The working width must be programmed in meters, and the position of the comma is fixed with two
digits on both sides (e.g. 12,00).
The area counter contains two counters (Area I and Area II). Both of them are resetable.
A flashing segment in the bottom left corner of the display, indicates when area counting is taking
place, that is, when pulse signals are received.
The Flex Counter calculates the area (just as it does units in the unit counter mode) with more
decimals, than it is able to show on the display. Therefore it may sometimes appear that counting
errors are occurring, even though that is not the case.
1.3 Unit counter (F.3)
Before the unit counter can be used, the counting factor must be set, i.e. the factor by which the total
number is increased when receiving a pulse signal. This factor will usually be 1, but as illustrated in
scheme “The relationship between functions and input-/outputfactors”, it can be set between 0,001 and
9,999. The unit counter can then be used for the measuring of distance, flow etc.
Measuring distance: Mount the magnet on a trailing wheel, and set the counting factor to the distance
driven for each pulse signal (the wheel circumference divided by number of magnets applied). The
display will then show the driven distance.
Registrating flow: In case a flowmeter that supplies a set number of pulses per litre is connected to the
Flex Counter, the counting factor is set to the amount of flow per pulse. The display will then show the
total amount of liquid delivered.
The display will show the total number in 1/1000, e.g. 10 pulses will be shown as 0,010 when the
counting factor is set to 1,000. When working with small counting factors the display will only be

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 5
updated with rather large intervals. A flashing segment in the bottom left corner will therefore indicate
when pulse signals are being received.
The unit counter can be reset - please refer to the paragraph “Changing and resetting values”.
1.4 Revolution counter (F.4)
The revolution counter may be used for monitoring the number of revolutions per minut, e.g. on a shaft
or sowing wheel. Revolutions per minut are displayed in the interval 12-9999 rpm.
The function also contains a timer, counting up the hours and minutes while the computer is receiving
pulse signals from the sensor. The Flex Counter must receive a signal every 5 second - otherwise the
timer is paused. Up till 99 hours and 59 minutes, the timer will show both hours and minutes.
Thereafter only hours will be displayed.
Intervals for displaying RPM- and working hours
Interval Display example
< 100 hours 54:23
=> 100 hours 1275
The RPM timer may be reset according to the instructions given in paragraph “Changing and resetting
values”.
1.5 Working hours (F.5)
This function counts up the amount of time gone, while the sensor is constantly short-circuited. If the
Flex Counter is to be used as a stopwatch, this can be done by short-circuiting the sensor with the
magnet, or by installing a switch instead of the sensor. The watch may then be started and stopped
using this switch. A flashing segment in the bottom left corner of the displayed indicates when the
watch is activated.
Working hours may be reset as described in the paragraph “Changing and resetting values”. The
previous paragraph “Revolution counter (F.4)” describes how different times are displayed.
1.6 Wrap counter (F.6)
The wrap counter is constructed for monitoring the wrapping of bales in folio. It monitors, the number
of rotations a bale has been given and gives automatic alarm (the display flashes) when the required
numbers of rotations are about to be reached. At the same time, the values of the two bale counters are
both increased by one.

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 6
The alarm is being activated:
• 1 rotation before the pre-set required number of rotations is reached. When the next pulse signal
is received the alarm stops, but are activated again, if one or more pulses are received. The
audio alarm automatically stops after one minute.
The values of the bale counters are increased by one when:
• The pre-set required number of rotations is reached.
The wrap counter is reset :
• When the required number of rotations has been reached, and the computer does not receive any
more pulse signals within a 10 seconds period.
• The SET -key is pressed while the display shows the wrap number (PULS function).
2. Operation guide
2.1 Overview
Dis
p
la
y
In several functional modes
the bottom ”bar” will flash
during work (when the
monitor receives sensor
input)
SET-key
• Start-up
• For activating the
change function of
the value marked/
highlighted
F-key (or C-key)
• Start-up
• Change of active
parameter displayed
• Change of the value
marked/highlighted
• Turning off the Flex
Counter – Press the key
for approx. 4 seconds
(”stop” is displayed in
the monitor
)
Connector
• Input for sensor
signal

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 7
2.3 Changing and resetting values
The table below shows which values that may be changed and which may only be reset. Values that
may be changed (indicated by a C) are all input factors, and values that may only be reset (indicated by
an R) are all output factors
.
THE RELATIONSHIP BETWEEN FUNCTIONS AND INPUT-/-OUTPUT FACTORS
No. Function Factors Display symbol May be Reset
or Changed Limits
F.1 Speed indicator Speed C 0,000 - 999,9 km/h
Wheel
circumference o0,000 - 999,9 cm
F.2 Area counter Area I HA.1 R 0,000 - 9999 ha
Area II HA.2 R 0,000 - 9999 ha
Wheel o
circumference Machine model freewheel sensor number to enter
PROSEM 396
648
Machine model wheel type number to enter
ED-1003/EURO-888 7.50-16 30,85 C00,01 - 999,9 cm
SD-1303 11.5/80-15.3 28,30
SD-1203 - 24,68
10,80-12
TRI 194-294 27,79
6,00-16 29,20
TRI 2110 10.75-15,3 28,80
CERES TM 2612 3.50-8 24,08
EUROPA-2000 6,00-16 14,60
EUROPA/FERTIS. 7,50-16 15,43
SD-3000/R15 - 14,20
Working width Machine model Working width
PROSEM number of rows x Distance between elements C 00,01 - 99,99 m
others depends to chassis type
F.3 Unit counter Units cou. R 0,001 - 9999 pcs.
Counting factor cou.F C 0,001 - 9999 pcs.
F.4 Revolution Rpm r. 0012 - 9999 rpm
counter RPM-hours ·R 00:00 - 9999 hours
F.5 Working hours Working hours ·R 00:00 - 9999 hours
F.6 Wrap counter Wrap counter PULS R 0 - 99 rev.
Wrap number PULS C 2 - 99 rev.
Bales I bAL.1 R 0 - 9999 bales
Bales II bAL.2 R 0 - 9999 bales
··· :
··· :
The programming rules of the Flex Counter are described below. Furthermore, the paragraph
“Overview of included functions” gives a more thorough description of the 6 functions and their
attached input- and output factors.
2.2 Change of active function
Changing from one function to another is done in the following manner:
Example: Changing function
Key Display Explanation
F
0 9 F. 1 The current function number is found on the display.
SETF. 1 Press the key for app. 2 sec. - the function number starts flashing, indicating that
its value may be changed.
F
0 9 F. 3 Push repeatedly until the function number is correct.
SETF. 3 Press the key for app. 2 sec. - the change is completed.

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 8
If values (e.g. wheel circumference or working width) are to be changed, the function containing the
specific value must first be entered - please refer to the paragraph above “Change of active function”.
Following the procedure described below changes values:
Example: Changing the wheel circumference from 87,25 cm to 315,8 cm
Key Display Explanation
F
0 9
o
87.25 The wheel circumference is found on the display - first the symbol is displayed,
then the current wheel circumference value.
SET 87,25 Press the key for app. 2 sec. - the comma starts flashing, indicating that its
position may be changed.
F
0 9
872,5 Push repeatedly until the position is correct.
SET 872,5 The first digit starts flashing, indicating that its value may changed.
F
0 9
372,5 Push repeatedly until the digit value is correct.
SET 372,5 The second digit starts flashing.
F
0 9
312,5 Push repeatedly until the digit value is correct.
SET 312,5 The third digit starts flashing.
F
0 9
315,5 Push repeatedly until the digit value is correct.
SET 315,5 The fourth digit starts flashing.
F
0 9
315,8 Push repeatedly until the digit value is correct.
SET 315,8 Press the key for app. 2 sec., leaving programming.
Not all factors contain a comma, just as it is not always possible to change its position. In those cases,
please disregard the instructions on changing the position of the comma!
Example: Resetting the Area counter
Key Display Explanation
F
0 9
HA.1
7.192 The area counter I is found on the display - first the symbol is displayed, then
the current accumulated area.
SET 7,19 Press the key for app. 2 sec. - the comma starts flashing, indicating that its
position may be changed.
F
0 9
0 Press until the area counter is reset.
SET 0 Press the key for app. 2 sec., leaving programming.
Furthermore, programming-mode is automatically exited, if the Flex Counter does not receive signals
from the keys within a 10 second interval.
All factors will retain their value when changing function. If a value for the wheel
circumference has previously been entered, e.g. under speed indication, this procedure will
not have to be repeated.

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 9
2.4 Turning the Flex Counter on and off - stop-mode
In order to lower the power consumption of the Flex Counter, and thereby increasing the lifetime of the
batteries, the computer may be set in stop-mode. The display will then be turned off and the computer
is paused until a new signal is received from the sensor or a pressed key.
The Flex Counter may be set in stop-mode manually. This is done by pressing the 0 9
F-key for app. 4
seconds. The display shows 'stop' in app. 1 second, and the display is then turned off.
If the Flex Counter within a period of ½-1½ hour has not received any pulse or key-press signals, the
computer is automatically set in stop-mode.
2.5 Power supply
The Flex Counter must be supplied with power from 2 1,5V AA-batteries.
When the Flex Counter is re-started having been in stop-mode, the display first shows the version
number of the specific computer.
The computer then checks the power level - if this is to low the display shows '-bL'. If the Flex Counter
is then automatically turned off, the batteries must be changed. If the power supply from the batteries
are to low the computer will occasionally flash the '-bL-' message during use. The batteries must then
to be changed, as counting errors may then occur.
If display-problems occur after battery replacement, wait for 2 minutes, and then reinstall the batteries.
In case this doesn’t help please check the accumulated voltage from the batteries (min. 3V).
2.6 Storing data – The memory of the Flex Counter
The Flex Counter is supplied with a memory facility, which remembers the values of the input- and
output factors.
The values of the input-factors (e.g. the wheel circumference) are automatically stored when they are
changed.
The value of output factors (e.g. area I) is stored once every hour, and when the Flex Counter is
automatically or manually set in stop-mode - please refer to the “Turning the Flex Counter on and off -
stop mode”.
When changing the batteries, the Flex Counter must first be manually set in stop-mode, using
the 0 9
F-key. Then the batteries may be changed without risk of loosing data

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 10
3. Installing the sensor and magnet
The magnet must be mounted on the rotating element, e.g. the wheel, the shaft, or the rotating table of
the wrapper.
The sensor must be installed on a bracket, securing that the magnet passes the sensor end within a
distance of 2-8 mm - please see the diagram below.
Please take notice that the cable from the sensor will be protected and not break when the tractor is
turning, or the hydraulic is activated.
4. Technical data
Display: 4 digit.
Power supply: 2 x 1,5 V (AA).
Temperature limits: The Flex Counter is fully operational within –10o C – 70oC.
This does not necessarily apply for all types of batteries –
please check with your local battery dealer.
Pulse signals from the sensor: Max. 167 pulse signals per second.
Min. pulse-time: 0,6 ms ~ the magnet must activate the sensor
for 1/10 of the time at 9999 rpm.
Area counter: Max. 0,100 Ha. per second = 360 Ha. per hour.
Unit counter: Max. 0,167 additions per second = 10.000 pcs./10 m3 per
minute, and 600.000 pcs./600 m3 per hour.
Clock: +/- 0,5%. Has influence on the accuracy of the following
functions: speed (km/h), rpm and working hours.
2 - 8
mm
Min. 5 mm.
Please notice:
Iron bracket
If the sensor is to be mounted on
a mounting bracket which is mag-
nitzable (ron), then the sensor
be placed at least 5 mm beyond
Magnet the edge of the mounting bracket.
must

Flex Counter Standard
Program version: Flexcounter 1.6
Flex Counter Standard
Manual Version: UK 1.1
Page 11
5. Final remarks
The controller/monitor is only to be used in connection with the functions described in this instruction
manual. Any other use of the controller/monitor can potentially involve significant risk and disclaim
the supplier of this controller/monitor for any responsibilities/liabilities.
Please note, that Lykketronic A/S solely is responsible for the electronic controller/monitor and not for
the complete function of the machine, including the safety aspects of the entire machine.

Notes
Page 12

Notes
Page 13

Table of contents