LynxNet LN-2400DH User manual

www.lynxnet.co.nz
INSTALLATION
MANUAL
LN-2400DH
Multi-Room Distribution Hub
M
100310

www.lynxnet.co.nz
LN-2400DH MULTI-ROOM DISTRIBUTION HUB
LN -2400DH MULT I -ROO M D I ST RI BUT I ON HUB
KIT CONTENTS
Multi-Room Distribution Hub
Qty: 1 Pc
Part Code: LN-2400DH
Computer Network Patch Cables
Qty: 8 Pcs
Part Code: LN-CAT5-0.3BL
Telephone Patch Cables
Qty: 8 Pcs
Part Code: LN-CAT5-0.3GY
IR Patch Cables
Qty: 2 Pcs
Part Code: LN-CAT5-0.3RD
IR Target
Qty: 1 Pc
Part Code: LN-IRT
IR Emitter
Qty: 1 Pc
Part Code: LN-IRE
2
M

www.lynxnet.co.nz
OVERVIEW
General Description
The LN-2400DH is an “All in One” distribution hub
designed to be installed during the construction or
renovation of a home or small office.
Installation of the panel will help “Future Proof”
your home or office through the flexible distribution
of:
Telephone Outlets•
FM/UHF Antenna Signals•
Satellite Signals•
Computer Network•
Internet Connections•
Remote Control Repeaters•
The system comes completely assembled and
configured to minimise installation time and allow
for quick, easy and flexible distribution to up to 24
room outlets within your home or office.
Features of this innovative Distribution Hub include:
Easy Installation & Configuration•
24 x Configurable Room Outlets•
12 x Antenna Outlets•
8 x Computer Network Ports•
8 x Telephone Outlets•
6 x IR Repeater Ports•
10/100 Base Network Hub•
Independent FM/UHF/SAT Gain•
Satellite Signal to All Antenna Outlets•
Sky/Free-View Distribution•
FM/UHF/SAT Inputs•
ADSL Modem Port Including Filter•
18 x CAT5E Patch Leads Included•
1 x RF Modulator Input (Security Camera’s, DVD•
Players, Set-Top Box)
Antenna Distribution
Dedicated inputs are provided for F M , UHF
Antennas and Satellite dish.
An onboard amplifier provides individual control of
each input giving full flexibility when balancing the
system.
Output from the Amplifier provides F M , UHF,
Satellite & AV modulated signals to up to 12 room
outlets. You will now have complete flexibility of
your Set-top box location within the home combined
with the balanced sharing of modulated signals.
All outlets are power-pass capable allowing a
Set-top box to pass power to the Satellite dish.
The Satellite dish may also be powered from the
Amplifier by setting the LNB switch to 13 or 18
volts.
A 12 volt output is provided through the UHF Input
connector to power an optional (not included) Mast-
head amplifier.
Computer Network
An onboard 10/100 Mbps Ethernet Switch provides
distribution for an 8 port computer network.
Port 1 is used as an input from the ADSL Modem,
while ports 2-8 may be patched to any one of up to
24 room outlets using the blue patch leads.
Green LED’s indicate the status of each port.
Telephone Distribution
The LN-2400DH allows for 2 incoming lines.
Line 1 and 2 are punched down on the rear of
the patch panel.
Termination is also provided to allow the main
Telephone line to go via a monitored Alarm
panel.
An onboard ADSL filter provides filtered signal
to the 8 Telephone ports on the front of the
patch panel. These 8 Telephone ports can be
patched to any one of up to 24 room outlets
using the grey patch leads.
Line 2 (if connected) has 1 port on the front of
the patch panel which can be patched to any
one of up to 24 room outlets using a grey patch
lead.
IR Distribution
The LN-2400DH provides onboard circuitry to
receive and distribute infra-red remote control
signals via the 6 IR ports on the front of the
patch panel, which can be patched to any one
of up to 24 room outlets using the red patch
leads.
Multiple IR receivers can be used to send IR
signals to one or more products.
3

www.lynxnet.co.nz
LN-2400DH MULTI-ROOM DISTRIBUTION HUB
LN -2400DH MULT I -ROO M D I ST RI BUT I ON HUB
INSTALLATION DIAGRAM
M
413mm
313mm
96mm
3
2
1
4
3
12
8
9
10
11
3
6
5
7
1Telephone/Alarm cable entry
2RG6/RG59 Antenna cable entry
3Mounting Holes
4CAT5e cable entry
5Removable door surround
6230VAC Mains cable entry
7Antenna Amplifier adjustments
8 RJ-45 Room outlets
9RJ-45 Telephone ports
10 RJ-45 Infrared Repeater ports
11 RJ-45 Network ports
12 RJ-45 ADSL Modem port
4

www.lynxnet.co.nz
WALL MOUNTING
M
M
Mounting Holes
Removeable door surround.
May be rotated and installed as
Right or Left hanging door.
Additional framing
maybe added to provide
further support
NOTE: Ensure the case is
installed 10mm proud of the
framing to allow for the thickness
of the plasterboard wall linning
350mm
95mm
10mm
5

www.lynxnet.co.nz
LN-2400DH MULTI-ROOM DISTRIBUTION HUB
LN -2400DH MULT I -ROO M D I ST RI BUT I ON HUB
CAT5e CABLE CONNECTION
87654321
T568B
CAT5e
8 7 6 5 4 3 2 1
T568B
CAT5e
16 15 14 13 12 11 10 9
T568B
CAT5e
24 23 22 21 20 19 18 17
T568B
CAT5e
LN-2400DH
10/100 NETWORK SWITCH
TELEPHONE/IR DISTRIBUTION
JP1
JP2
BYPASSLINKS
REMOVE LINKSWHEN
ALARM INSTALLED
TO ALARM
FROM ALARM
LINE 2
LINE 1
+
18VDC
M
Cat5e Termination
As shown in the above diagram, terminate all room outlet CAT5e cables to conform with the T568B
colour code standard.
Using a “punch down” cron tool, start from the right (outlet1), finishing on the left (outlet 8)
The cable clamp is designed to secure 8 cables. In the event less than 8 cables are to be installed,
cables ties may be required.
INSTALLATION TIP: When running cables ensure a minimum of 2 Cat5e cables are run to each room.
ADSL Modem distribution uses 2 cables.
To Room
outlet 1
Blue / W
Blue
Green / W
Green
Orange / W
Orange
Brown
Brown / W
Cable
clamp
CAT5e Cable
6

www.lynxnet.co.nz
TELEPHONE CABLE CONNECTION
8 7 6 5 4 3 2 1
T568B
CAT5e
16 15 14 13 12 11 10 9
T568B
CAT5e
24 23 22 21 20 19 18 17
T568B
CAT5e
LN-2400DH
10/100 NETWORK SWITCH
TELEPHONE/IR DISTRIBUTION
JP1
JP2
REMOVE LINKS WHEN
ALARM INSTALLED
TO ALARM
FROM ALARM
LINE 2
LINE 1
+
18VDC
BYPASS LINKS
JP1
JP2
M
Security Alarm Panel
If a Security Alarm panel is installed, provision has been made to allow the main Telephone line to pass
through the Secuirity panel. This enables the security system to take priority over the line in the event of
an activation.
Using standard two core cable, connect the security panel as shown above. Remove the two “Links” JP1
& JP2 to allow the phone line to pass through the system.
Main phone line input
Security
alarm panel
Remove links when
alarm installed
Telephone Distribution PCB
Optional second
line input
Telephone line(s)
Connect the main incoming Telephone
line as shown below. Provision has also
been made for the second line as shown
7

LN-2400DH MULTI-ROOM DISTRIBUTION HUB
www.lynxnet.co.nz
ANTENNA DISTRIBUTION AMPLIFIER
Antenna Cable Connection
As shown above, Antenna cables from the roof & room outlets enter the distribution case from the opening
in the top of the case.
It is recomended that all Antenna cables be of the RG6 type and terminated with Radial or Hex type crimp
connectors.
A minium of (3) RG6 cables should be run from the roof to allow for FM , UHF & Satellite signals.
It is also recommend that (2) or more cables be run to the main entertainment area, allowing for “Set top
Box” signals to be routed back to the distribution hub for distributing modulated signals to other rooms.
M
M
1 INPUTS
FM: 47~230Mhz
FM Antenna input
Adjustable -10dB Anttenuation ~ +10dB Gain
UHF: 470~862Mhz
UHF Antenna input
Adjustable -10dB Anttenuation ~ +10dB Gain
Includes 12VDC output for optional Masthead
Amplifier power
UHF1: 470~862Mhz
UHF Modulator input
Adjustable -10dB Anttenuation ~ +10dB Gain
S AT: 950~2150Mhz
Satellite dish input
Adjustable -10dB Anttenuation ~ +10dB Gain
2 S atellite LNB voltage select switch
13V: Vertical Polarisation
Select switch to this position to provide 13VDC
to the Satellite LNB from the Amplifier power
supply.
18V: Horozontal Polarisation
Select switch to this position to provide 18VDC
to the Satellite LNB from the Amplifier power
supply.
STB: S et Top Box - Power pass.
Select switch to this position to allow power to
pass from Set Top box (i.e SKY) via any one of
the 12 outputs to Satellite dish LNB.
3 Outputs
12 Room outlets
All 12 outlets contain SAT IF, FM , UHF &
modulated signals. Any of the 12 outlets
outlet is capable of passing DC power back
to the satellite dish when the LNB voltage
select switch is set to STB
4 Antenna input adjustments
Indepandent anttenuation or gain of -10dB to +10dB
4
3
2
1
8

www.lynxnet.co.nz
ELECTRICAL POWER SUPPLY CONNECTION
L
N
AC INPU
T
E
N
P
M
18V power supply
1.5mm 2TPS
Electrical 230VAC Input
This Distribution hub includes an internal switch mode power supply. A 230V AC connection is required
as shown above. Use standard 1.5mm TPS cable for this connection .
NOTE: This connection must be done by a registered Electrician
9

www.lynxnet.co.nz
LN-2400DH MULTI-ROOM DISTRIBUTION HUB
LN -2400DH MULT I -ROO M D I ST RI BUT I ON HUB
PATCHING
M
ADSL
M
COMPUTER NET WORK
10

www.lynxnet.co.nz
PATCHING
M
M
T E L EPHONE
IR
11

www.lynxnet.co.nz
LN-2400DH MULTI-ROOM DISTRIBUTION HUB
ROOM OUTLET TABLE
Room Outlet Location (ie boardroom 1 Kitchen etc) Use (ie telephone, Data, IR etc)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
12