manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-Sure
  6. •
  7. Scale
  8. •
  9. M-Sure MS-270 Series User manual

M-Sure MS-270 Series User manual

m-sure.co.uk
www.m-sure.co.uk - Allendale Group Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.
Images & Content ©2020 Allendale Group Limited. E&OE - Specifi cations subject to change without prior notice.
M-SURE Digital Scales User Manual
• Before using the Linear Scale for the fi rst time, wipe with a clean cloth ideally soaked with cleaning oil.
• This M-SURE Linear Scale is a precision measuring instrument. Avoid using excessive force, and treat with care.
• The fi tted battery is intended for the factory test procedure and therefore may not meet the specifi ed battery life.
• Avoid exposure to all liquids, excessive humidity or temperature.
• Avoid exposure to bright sunlight.
• Never apply voltage on any part of this Linear Scale or electric engrave.
• Remove the battery if the Scale is not being used for a long period of time.
• Never use solvents to clean. Only use a soft cloth with cleaning oil.
• Ensure the Linear Encoder is mounted parallel and in correct alignment to the machine axis.
Precautions
Battery Replacement (MS-270 Series only)
Linear Digital Scale
0
5
10
15
20
25
30
35
40
45
The Linear Scale must be aligned
parallel to the machine travel. Use a
Dial Gauge or DTI to set parallel.
The travel of the reading head must
also be aligned correctly to the Scale
beam, otherwise damage will occur.
1. Beam clamp
2. Beam
3. Reading head
4. LCD display
5. Function button
6. Battery cover
7. Data output cover
8. Reading head fi xing - M3
Horizontal Type
Vertical Type
Part No: MS-270 & 272 Series
Doc V: 1.0
M-SURE Digital Scales
47
3
1
2
2
3
5
7
8
4
6
5
6
8
1
1. Insert the key into the battery cover.
2. Twist to unlock. DO NOT use
excessive force.
6. Insert the replacement battery with
its edge against the side battery contact.
7. Press down on the opposite edge.
3. Lift out the battery cover.
8. Locate the two lugs on the battery
cover with the two slots on the Scale.
Insert the battery cover.
4. Remove the battery. (A magnet tip tool can
be used)
5. Locate the side spring battery contact.
9. Twist to lock. DO NOT use
excessive force.
1
2
3
4
5
6
7
8
9
m-sure.co.uk
www.m-sure.co.uk - Allendale Group Ltd, Pindar Road, Hoddesdon, Hertfordshire. EN11 0BZ.
Images & Content ©2020 Allendale Group Limited. E&OE - Specifi cations subject to change without prior notice.
M-SURE Digital Scales User Manual
Trouble Shooting
Metric/Inch conversion
1.000
The display will indicate
which units are being
displayed.
in/mm

in
How to zero a Linear Scale
Problem Possible Cause Solution
Flashing display Low voltage
Poor contact
Replace battery
Clean contact
No display Dead or weak battery
Poor contact
Replace battery
Clean contact
No change to display Internal error
"H" shown on display
Remove battery for 1 hour
Remove battery for 5 minutes
Can't zero Hold function active Switch off function
Erratic or frozen display Contamination between beam & head
low voltage
Wipe clean
Replace battery
Erroneous reading Low voltage
Contamination between beam & head
Scale not parallel to travel
Low ambient temperature
Replace battery
Wipe clean
Adjust parallel with dial gauge/DTI
Store at normal room temperature
1. Slide open the battery
cover.
2. Remove battery. (A magnet tip
tool can be used)
3. Locate side spring contact.
4. Insert replacement battery
edge against side contact.
5. Press down on other edge.
6. Slide battery cover closed.
Side Type Battery Replacement (MS-272 Series only)
0.00 ZERO

Press ZERO to clear.
mm 25.40 in/mm

Press in/mm to convert from
inch to metric display.
mm
Scales with ABS Function (MS-272 Series only)
10.00
mm
Measure workpiece, for
example 10mm.
0.00
mm
ZERO
Close Scale. Press ZERO
button.
5.00
mm
ABS

Press the ABS button once to
change between ABS mode
and INC mode. (Not displayed)
ABS 15.00 ABS

Press ABS to switch back to
Absolute display.
mm
1
3
4
2
5
6

This manual suits for next models

1

Popular Scale manuals by other brands

Kompernass KH 804 operating instructions

Kompernass

Kompernass KH 804 operating instructions

KERN RFC Service manual

KERN

KERN RFC Service manual

RADWAG HRP.R Series user manual

RADWAG

RADWAG HRP.R Series user manual

Scarlett SC-BS33E050 instruction manual

Scarlett

Scarlett SC-BS33E050 instruction manual

Tanita 3500 Operator's manual

Tanita

Tanita 3500 Operator's manual

Black & Decker BK50 manual

Black & Decker

Black & Decker BK50 manual

Sartorius YDK 01 user manual

Sartorius

Sartorius YDK 01 user manual

Escali B200 user guide

Escali

Escali B200 user guide

Westinghouse WHKS02K instruction manual

Westinghouse

Westinghouse WHKS02K instruction manual

Surpahs STT-978BL user manual

Surpahs

Surpahs STT-978BL user manual

Velleman VTBAL2 user manual

Velleman

Velleman VTBAL2 user manual

Orbegozo PB 2211 user manual

Orbegozo

Orbegozo PB 2211 user manual

ADE KE 1501 operating manual

ADE

ADE KE 1501 operating manual

Seca 769 owner's guide

Seca

Seca 769 owner's guide

Hocom AEPL-M Series user manual

Hocom

Hocom AEPL-M Series user manual

Weighstation F177-A instruction manual

Weighstation

Weighstation F177-A instruction manual

Rice Lake Digi DC-100 Operation manual

Rice Lake

Rice Lake Digi DC-100 Operation manual

Universal Weight Electronics VGW Series Operation manual

Universal Weight Electronics

Universal Weight Electronics VGW Series Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.