R7M-DA16F
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Discrete input module...................................................... (1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
•The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrat-
ed in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■POWER INPUT RATING & OPERATIONAL RANGE
•Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 40mA
■GENERAL PRECAUTIONS
•Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
•Indoor use.
•When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
•Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
•The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
DISCRETE INPUT MODULE, 16 points
(Modbus 115.2 kbps) MODEL R7M-DA16F
INSTRUCTION MANUAL
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax:
+81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7803-AW Rev.1 P. 2 / 4
R7M-DA16F
COMPONENT IDENTIFICATION
■ SIDE VIEW ■ FRONT VIEW
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
ERR RD
RUN SD
PWR X10 X1
NODE ADD. B.RATE
12345678
01234567
4567
123
10 11 12 13
2341
15 16 17 18
7896
14
5
(A) Status Indicator LED
(B) Node Address Setting Rotary SW
(C) Baud Rate Setting Rotary SW
(D) Operating Mode Setting DIP SW (SW1)
(E) PC Configurator Jack
(F) Discrete Input Status Indicator LED
(G) Modbus, Power Supply Terminals
(H) Input Terminals
( I ) Terminating Resistor SW
(A)
(G) (H)
(B) (C) (D) (E) (F)
89ABCDEF
CNFG.
(I)Terminating Resistor SW
TERM
ON OFF
■STATUS INDICATOR LED
ID COLOR FUNCTION
PWR Red Turns on when the internal 5V is supplied
normally.
RUN Red Turns on when the refresh data is received
normally.
ERR Red Turns on when the received data is abnor-
mal.
SD Red Turns on when the module is transmitting.
RD Red Turns on when the module is receiving.
■NODE ADDRESS
Node Address is selected between 1 and 99 in decimal. The
left switch determines the tenths place digit, while the right
switch does the ones place digit of the address.
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
Node Address Setting (x1)
Node Address Setting (x10)
■BAUD RATE
Baud Rate is selected with the rotary switch.
5
4
3
2
1
0
9
8
7
6
Baud Rate Setting
0: 38.4 kbps
1: 19.2 kbps
2: 9600 bps
3: 4800 bps
4: 2400 bps
5: 1200 bps
6: 14.4 kbps
7: 28.8 kbps
8: 57.6 kbps
9: 115.2 kbps
■OPERATING MODE
• Extension (SW1-1, 1-2)
SW1-1 SW1-2 Extension
OFF OFF No extension (*)
ON OFF Discrete input 8 or 16 points
OFF ON Discrete output 8 or 16 points
(*) Factory setting
Note : Be sure to set unused SW1-3 through 1-8 to OFF.
■POWER SUPPLY, MODBUS TERMINAL ASSIGNMENT
4
DA
567
123
DG +
24V 0V
DB SLD FG
(1) DB –
(2) SLD Shield
(3) FG FG
(4) DA –
(5) DG –
(6) +24V Power input (24V DC)
(7) 0V Power input (0V)
■INPUT TERMINAL ASSIGNMENT
10
COM
11
X1
12
X3
1
COM
2
X0
3
X2
13
X5
4
X4
14
X7
5
X6
15
X9
6
X8
16
XB
7
XA
17
XD
8
XC
9
XE
18
XF
NO. ID FUNCTION NO. ID FUNCTION
1 COM Common 10 COM Common
2 X0 Input 0 11 X1 Input 1
3 X2 Input 2 12 X3 Input 3
4 X4 Input 4 13 X5 Input 5
5 X6 Input 6 14 X7 Input 7
6 X8 Input 8 15 X9 Input 9
7 XA Input 10 16 XB Input 11
8 XC Input 12 17 XD Input 13
9 XE Input 14 18 XF Input 15
■EXTENSION MODULE
Combinations with all extension modules are available.
■DISCRETE INPUT STATUS INDICATOR LED
LED indicators show the signal status.
ON : LED ON
OFF : LED OFF
■PC CONFIGURATOR
The following parameters can be set with using PC Configu-
rator Software.
•Modbus parameters: Parity, bit length, stop bit
■TERMINATING RESISTOR
To use the terminating resistor, turn the switch ON, and
OFF to invalidate.
(Factory setting OFF)
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax:
+81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7803-AW Rev.1 P. 3 / 4
R7M-DA16F
EXTERNAL DIMENSIONS UNIT: MM (INCh)
4567
123
10 11 12 13
2341
15 16 17 18
789
6
14
5
30 (1.18) [5 (.20)]
3 (.12)5.5 (.22)
DIN RAIL
35 mm wide
54 (2.13)
17 (.66)
50 (1.97) 18.5 (.73)
115 (4.53)
7–M3 SCREW
TERMINALS
for Modbus, POWER
18–M3 SCREW
TERMINALS
for INPUT
6 (.24) 6 (.24)
CONNECTION DIAGRAM
Connect the unit as in the diagram below.
1
10
2
X0
COM
COM
–+
18
XF
1
10
2
X0
COM
COM
–+
18
XF
1
16
17
18
XB
15
X9
XF
XD
14
X7
13
X5
12
X3
11
X1
9
XE
8
XC
7
XA
6
X8
5
X6
4
X4
3
X2
2
4
7
6
3
2
5
1
X0
0V
24V DC
FG
SLD
DG
DB
DA
COM
COM
10
■ Input Connection Examples
PNP Connection NPN Connection
EXTENSION CONNECTOR
In order to improve EMC performance, bond the FG
terminal to ground.
Caution: FG terminal is NOT a protective conductor terminal.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax:
+81(6)6659-8510 E-mail: info@m-system.co.jp
EM-7803-AW Rev.1 P. 4 / 4
R7M-DA16F
MASTER CONNECTION
■MASTER CONNECTION
Tx+/Rx+
Tx–/Rx–
SG
Rx+
Rx–
Host PC
DA
DB
DG
SLD
FG
Remote Unit
DA
DB
DG
SLD
FG
Remote Unit
TERMINATOR TERMINATOR
Be sure to connect the terminating resistor included in the product package to the unit at both ends of transmission line.
The terminator must be connected across DA and DB.
The Host PC can be located other than at the extreme ends of transmission line.
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.5 N·m
■SOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable.
Applicable wire size: 0.25 to 1.65 mm2(AWG22 - 16)
Recommended manufacturer: Japan Solderless Terminal
MFG.Co.Ltd, Nichifu Co.,ltd
6 (.24) max
3.3 (.13) max
mm (inch)

Other M-system I/O System manuals

M-system JC-ECT User manual

M-system

M-system JC-ECT User manual

M-system M6 Series User manual

M-system

M-system M6 Series User manual

M-system R3-PD16C User manual

M-system

M-system R3-PD16C User manual

M-system R7M-DAC16C-R User manual

M-system

M-system R7M-DAC16C-R User manual

M-system R7ML-TS4 User manual

M-system

M-system R7ML-TS4 User manual

M-system R7M-DA16-R User manual

M-system

M-system R7M-DA16-R User manual

M-system R3-CT8C User manual

M-system

M-system R3-CT8C User manual

M-system R3-SV8 User manual

M-system

M-system R3-SV8 User manual

M-system R7ML-DC16B-R User manual

M-system

M-system R7ML-DC16B-R User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system R3Y-SV8N User manual

M-system

M-system R3Y-SV8N User manual

M-system R8-CT4E User manual

M-system

M-system R8-CT4E User manual

M-system R3-SV4A User manual

M-system

M-system R3-SV4A User manual

M-system R7D-TS4/UL User manual

M-system

M-system R7D-TS4/UL User manual

M-system R3S-RS4A User manual

M-system

M-system R3S-RS4A User manual

M-system R7ML-RS4 User manual

M-system

M-system R7ML-RS4 User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system R7F4HEIP-DAC16C User manual

M-system

M-system R7F4HEIP-DAC16C User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R7K4DH-1-DAC32A User manual

M-system

M-system R7K4DH-1-DAC32A User manual

M-system R7D-YV2 User manual

M-system

M-system R7D-YV2 User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R30NE1 User manual

M-system

M-system R30NE1 User manual

M-system R7C-DS4N User manual

M-system

M-system R7C-DS4N User manual

Popular I/O System manuals by other brands

ICP DAS USA PCI-D64HU user manual

ICP DAS USA

ICP DAS USA PCI-D64HU user manual

VTI Instruments EMX-75 Series user manual

VTI Instruments

VTI Instruments EMX-75 Series user manual

National Instruments PCIe-7856R manual

National Instruments

National Instruments PCIe-7856R manual

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Measurement Computing PCI-DAS64/M1/16 user guide

Measurement Computing

Measurement Computing PCI-DAS64/M1/16 user guide

jablotron JA-110N-DIN quick guide

jablotron

jablotron JA-110N-DIN quick guide

WAGO I/O System 750 Series manual

WAGO

WAGO I/O System 750 Series manual

Regin ADD:IO manual

Regin

Regin ADD:IO manual

ADLINK Technology DAQe Series user manual

ADLINK Technology

ADLINK Technology DAQe Series user manual

Allen-Bradley FLEX I/O 1794-IJ2 user manual

Allen-Bradley

Allen-Bradley FLEX I/O 1794-IJ2 user manual

Bticino F3N300 installation manual

Bticino

Bticino F3N300 installation manual

LST Triple Input/Output Module 55000-588 Specifications

LST

LST Triple Input/Output Module 55000-588 Specifications

ABB FDIO-01 user manual

ABB

ABB FDIO-01 user manual

Unitronics UG-ULK-EIP-4AP6 user guide

Unitronics

Unitronics UG-ULK-EIP-4AP6 user guide

Jetter JX3-BN-EC user manual

Jetter

Jetter JX3-BN-EC user manual

RJG Lynx OA1-M-V product manual

RJG

RJG Lynx OA1-M-V product manual

Advantech ADAM-6156PN user manual

Advantech

Advantech ADAM-6156PN user manual

Fastwel AIC324 user manual

Fastwel

Fastwel AIC324 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.