manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R3-BSW User manual

M-system R3-BSW User manual

Other M-system I/O System manuals

M-system R7D-YS2A User manual

M-system

M-system R7D-YS2A User manual

M-system M8BS1-16U0 User manual

M-system

M-system M8BS1-16U0 User manual

M-system R5-SS User manual

M-system

M-system R5-SS User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system R7M-MS4-R User manual

M-system

M-system R7M-MS4-R User manual

M-system R7D-CT4E User manual

M-system

M-system R7D-CT4E User manual

M-system R7D-SV4 User manual

M-system

M-system R7D-SV4 User manual

M-system R3-SS4 User manual

M-system

M-system R3-SS4 User manual

M-system R7D-SV4/UL User manual

M-system

M-system R7D-SV4/UL User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R80 Series User manual

M-system

M-system R80 Series User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R3-MS4 User manual

M-system

M-system R3-MS4 User manual

M-system R7M-DA16-R User manual

M-system

M-system R7M-DA16-R User manual

M-system 15BX-4 User manual

M-system

M-system 15BX-4 User manual

M-system R7C-CT4E User manual

M-system

M-system R7C-CT4E User manual

M-system R8-SS4N User manual

M-system

M-system R8-SS4N User manual

M-system R30XN16A User manual

M-system

M-system R30XN16A User manual

M-system R7F4HC-DC32B-K User manual

M-system

M-system R7F4HC-DC32B-K User manual

M-system JC-ECT User manual

M-system

M-system JC-ECT User manual

M-system R8-PA4 User manual

M-system

M-system R8-PA4 User manual

M-system R7D-DC8C User manual

M-system

M-system R7D-DC8C User manual

M-system R7C-YV4 User manual

M-system

M-system R7C-YV4 User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

R3-BSW
P. 1 / 3EM-8357 Rev.7
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
INSTALLATION BASE
(free I/O address) MODEL R3-BSW
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Base............................................................................... (1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
•The equipment must be mounted inside the instrument
panel of a metal enclosure.
•Theactualinstallationenvironmentssuchaspanelcon-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■GENERAL PRECAUTIONS
•Beforeyouremovethebaseormountit,turnoffthepower
supply for safety.
■ENVIRONMENT
•Indooruse
•Whenheavydustormetalparticlesarepresentintheair,
install the unit inside proper housing with sufficient ven-
tilation.
•Donotinstalltheunitwhereitissubjectedtocontinuous
vibration.Donotsubjecttheunittophysicalimpact.
•Environmentaltemperaturemustbewithin-10to+55°C
(14to131°F)withrelativehumiditywithin30to90%RH
in order to ensure adequate life span and operation.
■WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noisesarepresent.Donotinstalltheminthesameduct.
FRONT VIEW
I/O 1 I/O 2 I/O n
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SW1
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SW2
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SWn
–1
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SWn
I/O MODULE ADDRESS
FreeI/Omoduleaddresscanbeassignedtoeachmodulepo-
sition using the rotary switch, within 1 to 16. Every module
can be mounted on any position.
Switch positions and addresses correspond to each other as
shown below:
I/Omoduleaddress Rotaryswitchposition
10
2 1
: :
n n – 1
: :
16 F
DONOTassignoneaddresstomorethanoneI/Omoduleto
ensure adequate operations and to prevent failures.
In case of power supply module, interface module, they op-
erate normally even address is conflicted.
Forapowersupplymodule,besuretoinstallintheright
end slot or left end slot for heat dissipation. In the case of
redundant power supply, consecutively install them in the
right end slot or left end slot.
ExampleforR3-BSW04
I/O module address
Rotary switch position
4312
Power
Supply
Module
Interface
Module
I/O
Module
I/O
Module
3201
R3-BSW
P. 2 / 3EM-8357 Rev.7
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
INSTALLATION
■VENTILATION SPACE
TheR3-BSWmustbemountedonaverticalpanel.Mount-
ing in any other angle will cause internal temperature to
rise, may shorten the product’s life expectation or deterio-
rate its performance.
30 (1.2)
50 (2)50 (2)
40 (1.6)
R3-BSW
Panel ceiling or wiring conduit (height ≤50 mm or 2 in.)
Panel bottom or wiring conduit (height ≤50 mm or 2 in.)
■WALL MOUNTING unit: mm (inch)
108 (4.25)
30
(1.18)
13.5 (.53)
26
(1.02)
30
(1.18)
n–M4
*
*n = Number of slots ×2
■DIN RAIL MOUNTING
Spring Loaded
DIN Rail Adaptor
DIN Rail
35mm wide
Set the base so that its
mounting adapter is at the
bottom.
Pull out the adaptor and
hung the upper hook at
the rear side of base on the
DINrail.
Push in the lower and re-
tract the adaptor, in keep-
ing pressing the base to the
DINrail.
R3-BSW
P. 3 / 3EM-8357 Rev.7
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EXTERNAL DIMENSIONS unit: mm (inch)
130 (5.12)
108 (4.25)
5 (.20)5.5 (.22)
30 (1.18)
4 (.16)
26.5
(1.04)
5 (.20)
DIN RAIL
(35 mm wide)
16.7
(.66)
120 (4.72)
13.5 (.53)
A
26 (1.02) 30 (1.18) n–4.5 (.28) dia. MTG HOLE
2 (.08) deep
*n = Number of slots x 2
30 (1.18)
*
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SW1
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SW2
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SWn
−
1
8
6
7
3
4
5
2
1
0
F
E
D
C
B
A
9
SWn
SIZE
MODEL A
R3-BSW04 112 (4.40)
R3-BSW06 168 (6.61)
R3-BSW08 224 (8.82)
R3-BSW10 280 (11.02)
R3-BSW12 336 (13.23)
R3-BSW14 392 (15.43)
R3-BSW16 448 (17.64)