DISCRETE OUTPUT MODULE
(NPN transistor output, 16 points) MODEL
R30YN16A
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Discrete output module.......................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■CONFORMITY WITH EU DIRECTIVES
•The equipment must be mounted inside the instrument
panel of a metal enclosure.
•The actual installation environments such as panel con-
figurations, connected devices and connected wires may
affect the protection level of this unit when it is integrat-
ed in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure CE conformity.
■GENERAL PRECAUTIONS
•Before you remove the terminal block or mount it, turn off
output signals for safety.
■HOT INSERTION/REMOVAL OF MODULES
•It is possible to replace the module with the power sup-
plied, provided that modules are of the same model num-
ber and that the same Installation Base slot is used.
•Turn off output signals before replacing the module for
safety. Note that replacing multiple modules at once may
greatly change line voltage levels. We recommend that
you replace them one by one.
■ENVIRONMENT
•Indoor use.
•When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
•Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
•Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 10 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
•Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
•Be sure to attach the terminal cover for safety.
■AND ....
•The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
■OUTPUT AT THE LOSS OF COMMUNICATION
•Holds the output of the last normally received data.
•“Reset to 0” setting is not available.
R30YN16A
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-9011 Rev.1 P. 2 / 4
COMPONENT IDENTIFICATION
RUN
ERR
RUN LED
Output Terminal Block
ERR LED
■FRONT VIEW
■BOTTOM VIEW
■SIDE VIEW
Lock Tab
Base Fixing Screw
Specifications
Positioning Guide
Terminal Cover
1
5
9
13
2
6
10
14
3
7
11
15
4
8
12
16
Discrete Output Indicator LEDs
Terminal Fixing
Screw
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
■STATUS INDICATOR LED
ID
COLOR
FUNCTION
RUN Green ON in normal host communication
OFF in host communication error
ERR Red
OFF when internal bus operates normally
ON when an internal bus error occurs
Discrete Output Green ON when discrete output is ON
OFF when discrete output is OFF
■TERMINAL ASSIGNMENT
NO. ID FUNCTION NO.ID FUNCTION
1Y1Output 1 11 Y9 Output 9
2Y212 Y10 Output 10
3Y313 Y11 Output 11
4Y414 Y12 Output 12
5Y515 Y13 Output 13
6Y616 Y14 Output 14
7Y717 Y15 Output 15
8Y818 Y16 Output 16
9 24 V DC 19 V + 24 V DC
10 V –0V20V–0V
V +
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
11
Y9
12
Y10
13
Y11
14
Y12
15
Y13
16
Y14
17
Y15
18
Y16
19
V+
20
V–
1
Y1
2
Y2
3
Y3
4
Y4
5
Y5
6
Y6
7
Y7
8
Y8
9
V+
10
V–
R30YN16A
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-9011 Rev.1 P. 3 / 4
INSTALLATION
■INSTALLATION TO THE BASE
Use the Installation Base (model: R30BS).
The I/O slots are numbered in the ascending order starting
from the one on the immediate right side of the network
module (slot 1, slot 2...).
A code indicating the I/O slot number is assigned to each
I/O slot and I/O data is allocated in the order of this code.
When an I/O slot is vacant, blank data is sent or received to/
from the PLC, etc.
PWR COM I/O1 I/O n
■HOW TO MOUNT THE MODULE
1) Engage the positioning guide of the module with the In-
stallation Base.
2) Pivot the module on the positioning guide and press it
down until the lock tab sits into place.
Positioning Guide
3) Tighten the base fixing screw using a screwdriver (stem
length: 70 mm/2.76” or more) (torque 0.5 N·m).
Base Fixing Screw
■HOW TO REMOVE THE MODULE
1) Loosen the base fixing screw using a screwdriver (stem
length: 70 mm/2.76” or more).
Base Fixing Screw
2) While pressing the projection on the lock tab, push the
module upward.
3) Detach the positioning guide of the module from the In-
stallation Base.
Lock Tab
R30YN16A
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-9011 Rev.1 P. 4 / 4
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
■EXTERNAL DIMENSIONS unit: mm (inch)
①
②
③
④
⑪
⑫
⑬
⑭⑤
⑥
⑦
⑧
⑨
⑩
⑮
⑯
⑰
⑱
⑲
⑳
110 (4.33)
25 (.98) 98 (3.86)
20–M3
SCREW
6
(.24)
■CONNECTION DIAGRAM
3
1
4
2
5
6
7
8
19
13
14
12
15
16
17
18
9
10
20
11
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y9
Y10
V+
V+
Y11
Y12
Y13
Y14
Y15
Y16
V-
V- –+
V+
V+
V-
V- –+
1
10
20
9
18
19
Y1
Y16
BUS CONNECTOR
INTERNAL
BUS
INTERNAL
POWER
■Output Connection Example
WIRING INSTRUCTIONS
■TIGHTENING TORQUE
Separable screw terminal wiring screw: 0.5 N·m
Separable screw terminal fixing screw: 0.5 N·m
■SOLDERLESS TERMINAL unit: mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit.
Applicable wire size: 0.25 to 0.75 mm2
Recommended manufacturer: Japan Solderless Terminal
MFG. Co., Ltd., Nichifu Co., Ltd.
3.2 (.13) dia.
12 (.47) max.
6 max.
(.24)
3 (.12) max.
■HOW TO REMOVE SEPARABLE SCREW TERMINAL
The terminal block is separable in two pieces. Evenly loos-
en two screws on top and bottom of the terminal block to
separate.

Other M-system I/O System manuals

M-system R30SV4 User manual

M-system

M-system R30SV4 User manual

M-system R3-SV8A User manual

M-system

M-system R3-SV8A User manual

M-system R6S-DA4 User manual

M-system

M-system R6S-DA4 User manual

M-system R7E-PA8-R User manual

M-system

M-system R7E-PA8-R User manual

M-system R3-SS8N User manual

M-system

M-system R3-SS8N User manual

M-system R7HL-YV2 User manual

M-system

M-system R7HL-YV2 User manual

M-system R7L-TS4-R User manual

M-system

M-system R7L-TS4-R User manual

M-system R5T-RS User manual

M-system

M-system R5T-RS User manual

M-system R7C-MS4 User manual

M-system

M-system R7C-MS4 User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system R30SV2 User manual

M-system

M-system R30SV2 User manual

M-system R3Y-RS8 User manual

M-system

M-system R3Y-RS8 User manual

M-system Devicenet R7F4DD-DA16A-H User manual

M-system

M-system Devicenet R7F4DD-DA16A-H User manual

M-system R7F4HC-DAC32C-K User manual

M-system

M-system R7F4HC-DAC32C-K User manual

M-system R80 Series User manual

M-system

M-system R80 Series User manual

M-system R7F4HC-DC32B-K User manual

M-system

M-system R7F4HC-DC32B-K User manual

M-system R7F4DC-DA16A-J User manual

M-system

M-system R7F4DC-DA16A-J User manual

M-system R7M-DA16F User manual

M-system

M-system R7M-DA16F User manual

M-system R5-SV User manual

M-system

M-system R5-SV User manual

M-system R8-YS2 User manual

M-system

M-system R8-YS2 User manual

M-system R3-SS8 User manual

M-system

M-system R3-SS8 User manual

M-system R7L-EA16 User manual

M-system

M-system R7L-EA16 User manual

M-system R7G4FML3-6-DA16 User manual

M-system

M-system R7G4FML3-6-DA16 User manual

M-system R7I4DML3-DA32A User manual

M-system

M-system R7I4DML3-DA32A User manual

Popular I/O System manuals by other brands

Axon Cerebrum CGP-4848 Operation manual

Axon

Axon Cerebrum CGP-4848 Operation manual

Festo CPX-F8DE-P operating instructions

Festo

Festo CPX-F8DE-P operating instructions

GOWIN GW2AR Series user guide

GOWIN

GOWIN GW2AR Series user guide

Gude Expert Net Control 2312 user manual

Gude

Gude Expert Net Control 2312 user manual

Rockwell 1732DS-IB8XOBV4 installation instructions

Rockwell

Rockwell 1732DS-IB8XOBV4 installation instructions

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

SIIG JJ-E40011-S2 Quick installation guide

SIIG

SIIG JJ-E40011-S2 Quick installation guide

WAGO I/O SYSTEM 750 750-641 manual

WAGO

WAGO I/O SYSTEM 750 750-641 manual

Acrosser Technology ANR-DNV3N3-8C user manual

Acrosser Technology

Acrosser Technology ANR-DNV3N3-8C user manual

National Instruments PXIe-4322 CALIBRATION PROCEDURE

National Instruments

National Instruments PXIe-4322 CALIBRATION PROCEDURE

Tews Technologies TPMC310 user manual

Tews Technologies

Tews Technologies TPMC310 user manual

ICP DAS USA EC2-P32 quick start

ICP DAS USA

ICP DAS USA EC2-P32 quick start

National Instruments NI PXI-1042 Series quick start guide

National Instruments

National Instruments NI PXI-1042 Series quick start guide

Measurement Computing USB-DIO96H user guide

Measurement Computing

Measurement Computing USB-DIO96H user guide

Nico Technology 1208L user manual

Nico Technology

Nico Technology 1208L user manual

WAGO I/O SYSTEM 750 manual

WAGO

WAGO I/O SYSTEM 750 manual

NK TECHNOLOGIES AGT Series instructions

NK TECHNOLOGIES

NK TECHNOLOGIES AGT Series instructions

Siemens SIMATIC 6DL1193-6AR00-0AA0 Equipment manual

Siemens

Siemens SIMATIC 6DL1193-6AR00-0AA0 Equipment manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.