manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system Remote I/O R8 Series User manual

M-system Remote I/O R8 Series User manual

This manual suits for next models

1

Other M-system I/O System manuals

M-system R30SV2 User manual

M-system

M-system R30SV2 User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R7F4DC-DA16B-C User manual

M-system

M-system R7F4DC-DA16B-C User manual

M-system R7D-YV2A User manual

M-system

M-system R7D-YV2A User manual

M-system R80UST4 User manual

M-system

M-system R80UST4 User manual

M-system R7F4HML3-D-DAC32B User manual

M-system

M-system R7F4HML3-D-DAC32B User manual

M-system R8-YVT4N User manual

M-system

M-system R8-YVT4N User manual

M-system R3S-RS4A User manual

M-system

M-system R3S-RS4A User manual

M-system R80DCT16A2 User manual

M-system

M-system R80DCT16A2 User manual

M-system R5T-RS User manual

M-system

M-system R5T-RS User manual

M-system R7L-EA8 User manual

M-system

M-system R7L-EA8 User manual

M-system R7E-EC8B User manual

M-system

M-system R7E-EC8B User manual

M-system R3-SV16N User manual

M-system

M-system R3-SV16N User manual

M-system 60C User manual

M-system

M-system 60C User manual

M-system R7C-SV4 User manual

M-system

M-system R7C-SV4 User manual

M-system R7L-DC16B-R User manual

M-system

M-system R7L-DC16B-R User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system R3-SV8N User manual

M-system

M-system R3-SV8N User manual

M-system R7E-EC8A User manual

M-system

M-system R7E-EC8A User manual

M-system R7L-EA16 User manual

M-system

M-system R7L-EA16 User manual

M-system R30NE1 User manual

M-system

M-system R30NE1 User manual

M-system R1M-D1 User manual

M-system

M-system R1M-D1 User manual

M-system R30YN16A User manual

M-system

M-system R30YN16A User manual

M-system R5-SS User manual

M-system

M-system R5-SS User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

WAGO I/O-SYSTEM 750 manual

WAGO

WAGO I/O-SYSTEM 750 manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

MODEL: R8-PS1
R8-PS1 SPECIFICATIONS ES-9789 Rev.5 Page 1/3
https://www.m-system.co.jp/
Remote I/O R8 Series
EXTENSION POWER SUPPLY MODULE
(non-isolated)
Functions & Features
• Inserted between I/O modules and supply the power
• Up to two R8-PS1 use is available
24 [.94]
mm [inch]
115
[4.53]
72 [2.83]
MODEL: R8–PS1-R[1]
ORDERING INFORMATION
• Code number: R8-PS1-R[1]
Specify a code from below for [1].
(e.g. R8-PS1-R/Q)
• Specify the specification for option code /Q
(e.g. /C01)
POWER INPUT
DC power
R: 24 V DC
(Operational voltage range: ±10 %; ripple 10 %p-p max.)
[1] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
CAUTION
OUTPUT CURRENT & NUMBER OF CONNECTABLE UNIT
It is NOT available to connect 16 of R8-YV4N to
power/network module because of limitation of output
current of internal supply. The max. output current for
internal supply of power/network module is 1.6 A.
The max. consumption current for internal supply of R8-
YV4N is 160 mA.
1.6 (A) < 160 (mA) x 16 = 2.56 (A)
Inserting the R8-PS1 between 10th and 11th R8-YV4N
enables to connect 16 of R8-YV4N.
POWER UP
Turn the power on at the same time as the power/network
module or turn the R8-PS1 on before the power/network
module turned on. If the R8-PS1 is not turned on within 3
seconds after the power/network module is turned on, I/O
modules are not correctly recognized
GENERAL SPECIFICATIONS
Connection
•Power input, excitation supply: Tension clamp (Front Twin
connection)
Applicable wire size: 0.2 - 1.5 mm2
Stripped length: 10 mm
•Internal bus or internal power: Via connector
Max. number of I/O modules: 16
(Max. consumption current of I/O modules: 1.6 A)
Isolation: Internal bus or internal power or power input to
exc. supply to FE1
Power indicator LED: Green LED turns on when the power is
supplied.
INSTALLATION
Power consumption
•DC: Approx. 11 W 24 V DC (@ internal power max. current
1.6 A)
Internal power supply (power supply for I/O module):
• DC power supply: 5 V DC
• Current capacity: 1.6 A
Excitation supply output (excitation for I/O module)
•DC: 24 V DC ±10 %
•Operational current: 8 A
(From power supply, exitation supply connector, via
connector for internal bus, supplied to each I/O module.
Power output current consumption must be under
operational current.)
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: DIN rail
Weight: 100 g (0.22 lb)
PERFORMANCE
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(internal bus or internal power or power input to exc. supply
to FE1)
MODEL: R8-PS1
R8-PS1 SPECIFICATIONS ES-9789 Rev.5 Page 2/3
https://www.m-system.co.jp/
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EXTERNAL VIEW
■ FRONT VIEW ■ SIDE VIEW
Internal Bus Connector
Connector for Power Supply and
Excitation Supply
Power indicator LED
Unused
24V
0V
+
-
FE1
Power
CONNECTION DIAGRAMS
PIN ID FUNCTION
No.
1 24V Power supply 24V DC
2 0V Power supply 0V DC
3 + Excitation supply 24V DC
4 − Excitation supply 0V DC
5 FE1 Grounding
1
2
3
4
5
Note: The numbers marked on the connector have no relationship to the pin number of the unit.
Wire according to the instruction manual of the unit.
■ POWER SUPPLY, EXCITATION SUPPLY CONNECTOR ASSIGNMENT
Printed-circuit board connector (Phoenix Contact)
Unit side connector: MC1,5/5-GF-3,5
Cable side connector: TFMC1,5/5-STF-3,5
MODEL: R8-PS1
R8-PS1 SPECIFICATIONS ES-9789 Rev.5 Page 3/3
https://www.m-system.co.jp/
EXTERNAL DIMENSIONS unit: mm [inch]
115 [4.53](6 [.24])
(7 [.28]) (7 [.28])
(3 [.12]) (4 [.16])
(72 [2.83])
55 [2.17]
24 [.95]
(6 [.24])
DIN RAIL
(35 mm wide)
SCHEMATIC CIRCUITRY
Note: In order to improve EMC performance, bond the FE1 terminal to ground.
Caution: FE1 terminal is NOT a protective conductor terminal.
EXC. SUPPLY (24V)
INTERNAL POWER (5V)
INTERNAL BUS
INTERNAL BUS
+24V
0V
+−FE1
CONNECTOR
CONNECTOR
CONNECTOR
Internal bus is connected for the modules near to the power/network module out of the modules connected to the R8-PS1. Internal
power and Exc. supply are not connected. All modules far from the power/network module are connected.
POWER LED
Power
Circuit
(No isolation)
Specifications are subject to change without notice.