Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Signal conditioner ...............................................................(1)
■MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 35mA
■GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +55°C
(23 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
COMPONENT IDENTIFICATION
Body
Specifications
Front Cover
(Connection diagram
behind)
■FRONT VIEW (with cover open)
Span Adj.
Zero Adj.
1
78
56
2
34
INSTALLATION
Use Standard Rack (model: 18KBXx).
INPUT ISOLATOR MODEL 18KYV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-0487 Rev.1 P. 1 / 3
INSTRUCTION MANUAL
TERMINAL CONNECTIONS
Connect the unit as in the diagram below or refer to the connection diagram behind the front cover.
■EXTERNAL DIMENSIONS unit: mm (inch)
110 (4.33 )
93 (3.66)
24 (.94)
7 (.28)
78 (3.07)32 (1.26)
8–M3.5
SCREW
7 (.28)
2–M3
SCREW
■CONNECTION DIAGRAM
1
2
5
6
1
2
+
−
INPUT
OUTPUT 2
OUTPUT 1
+
−
OUTPUT 2
−
Section A. Field Terminals
Use either of module or external field terminals.
Module
Field Terminals
(Section A)
External
Field Terminals
(Section A)
POWER
CONNECTOR
■TERMINAL ASSIGNMENTS
12
34
78
56
18KYV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-0487 Rev.1 P. 2 / 3
WIRING INSTRUCTIONS
■SCREW TERMINAL
Torque: 0.8 N·m
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2) Power input voltage: Check voltage supplied to the rack
(model: 18KBXx). For the DC power source, be sure that
the ripple level is within 10% p-p.
3) Input: Check that the input signal is within 0 – 100% of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
ADJUSTMENT PROCEDURE
This unit is calibrated at the factory to meet the ordered
specifications, therefore you usually do not need any cali-
bration.
For matching the signal to a receiving instrument or in case
of regular calibration, adjust the output as explained in the
following.
■HOW TO CALIBRATE THE OUTPUT 1
Use a signal source and measuring instruments of sufficient
accuracy level. Turn the power supply on and warm up for
more than 10 minutes.
1) ZERO: Apply 0% input and adjust output to 0%.
2) SPAN: Apply 100% input and adjust output to 100%.
3) Check ZERO adjustment again with 0% input.
4) When ZERO value is changed, repeat the above proce-
dure 1) – 3).
5) No need of adjustments for the Output 2.
MAINTENANCE
Regular calibration procedure is explained below:
■CALIBRATION
Warm up the unit for at least 10 minutes. Apply 0%, 25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet. When the output is out of
tolerance, recalibrate the unit according to the “ADJUST-
MENT PROCEDURE” explained earlier.
LIGHTNING SURGE PROTECTION
M-System offers a series of lightning surge protector for
protection against induced lightning surges. Please contact
M-System to choose appropriate models.
18KYV
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
EM-0487 Rev.1 P. 3 / 3

Other M-system Switch manuals

M-system SHSP User manual

M-system

M-system SHSP User manual

M-system JC-CU User manual

M-system

M-system JC-CU User manual

Popular Switch manuals by other brands

NetComm NCT240 Manager user guide

NetComm

NetComm NCT240 Manager user guide

Pilz PSEN 1.2p-22 operating instructions

Pilz

Pilz PSEN 1.2p-22 operating instructions

mumbi m-IZ3500 user manual

mumbi

mumbi m-IZ3500 user manual

AVCOMM 610GX2 Quick installation guide

AVCOMM

AVCOMM 610GX2 Quick installation guide

NETGEAR XS728T ProSAFE Installation

NETGEAR

NETGEAR XS728T ProSAFE Installation

BSS Audio GS724T Features

BSS Audio

BSS Audio GS724T Features

Cygnus S1008-120-V1 user manual

Cygnus

Cygnus S1008-120-V1 user manual

TRENDnet TK-423K Quick installation guide

TRENDnet

TRENDnet TK-423K Quick installation guide

Agilent Technologies 3488 user manual

Agilent Technologies

Agilent Technologies 3488 user manual

Raritan DOMINION KSX II Quick installation and setup guide

Raritan

Raritan DOMINION KSX II Quick installation and setup guide

Asante FriendlyNet FH10T8 user guide

Asante

Asante FriendlyNet FH10T8 user guide

Ankuoo Neo Get started

Ankuoo

Ankuoo Neo Get started

Renesas IDT 89HPES12N3A user manual

Renesas

Renesas IDT 89HPES12N3A user manual

sysmik 2701927 Installation notes for electrical personnel

sysmik

sysmik 2701927 Installation notes for electrical personnel

Ross Carbonite Black Solo operating manual

Ross

Ross Carbonite Black Solo operating manual

Brydge Stone Pro user manual

Brydge

Brydge Stone Pro user manual

Panasonic ZEQUO 6700RE installation guide

Panasonic

Panasonic ZEQUO 6700RE installation guide

NETGEAR GS700AT Series Hardware installation guide

NETGEAR

NETGEAR GS700AT Series Hardware installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.