Installation Procedure:
Take a moment to view all drawings and read “special Installation note” on page 4 of this manual before proceeding with
installation. Connect aucet Autmator model A400 exactly as shown in drawing, with sensor cable connection at left.
ailure to install aucet Automator Model A400 exactly as shown will result in premature product failure and will void
all warranties including extended warranty. Also, do not forget step 7.
1. Make sure surface area is clean and free of debris.
2. **If usin deck plate, place plate on deck immediately over center sink hole**.
Install new faucet by placin sensor wire throu h the riser and the hole in the sink that is desi nated for spout.
Make sure that wire is not pinched or cut durin installation. Cutting or severely crimping sensor wire will cause faucet to
malfunction and will also void warrantee. Sensor wire is specifically desi ned to resist dama e, simple careful steps and
common sense is all that is necessary for a complete and rewardin installation process. You may use silicon or similar sealer
between faucet and deck plate.
3. Fasten Solid Brass Pipe Coupler to faucet shank usin plumbers putty or Teflon tape.
4. Affix Solid Brass Riser above plate (if used), then place faucet above Solid Brass Riser.
5. Slide rubber washer and stainless steel washer over faucet shank. Insert sensor wire throu h special “C” roove in washers.
6. Install retainer nut over faucet shank and ti hten. (Do Not Over Ti hten).
7. Remove stainless steel braided hose from packa e and fasten the small end of hose to threads located inside of shank.
8. Locate a spot on the wall that you feel is suitable for installin Faucet Automator FA400. The spot selected should be within
reach of braided hose and sensor wire. Place Faucet Automator FA400 a ainst the wall and mark the spots (2) where
mountin holes will be. Usin drill size ¼” drill 2 holes, insert supplied anchors in the holes.
This step is for battery Powered aucets Only. If your faucet is AC powered, skip this step.
9. Remove rubber band (or tape) that keeps the Faucet Automator’s cover to its base. Remove black square rubber cap off
battery compartment, plu battery wire harness into battery pack. Make sure that harness plu makes solid contact with
battery pack. Place black square rubber cap back onto battery compartment. Usin 4 small screws fasten Faucet Automator
cover to base.
10. Faucet Automator FA400 usin supplied fasteners.
11. Install shank hose to Faucet Automator’s water outlet (top).
12. Ali n roove in sensor wire plu with pin in Faucet Automator FA400 sensor receptacle, insert plu into receptacle, fasten
plu nut by hand only. DO NOT CROSS THREAD OR OVER TIGHTEN.
Before proceeding to steps 11 or 12, purge both hot and cold water lines for at least a minute each at high volume. Purging
water lines clears out dirt and debris that would otherwise find its way to screen filter.
***For sin le water source application install cold water supply hose to Faucet Automator’s water inlet. Do not install hot
water supply hose only in single water source application as this may result in scalding injury..
***For dual water temp system install mixin valve outlet to Faucet Automator’s water inlet.
Install hot and cold water supply hoses to mixin valve. Turn an le stops on. Check for leaks.
13. This step is for AC Powered aucets Only. Battery powered faucets ignore this step. Plug Automator to wall AC.
To enable the faucet to activate from a farther distance or to stay on longer after hands are removed, see “sensor range
adjustment” section of this manual.
To increase or decrease water flow volume, see “flow rate adjustment” section of this manual.
Operation:
Place hands under spout and directly in front of neck mounted sensor, water will be in to flow out in less than a second, water
flow rate is overned by aerator and supply pressure, water temperature is overned by selection at an le stops, mixin valve, as
well as water temperature in supply pipes. Please remember, automatic faucets employ “presence” not
“motion” sensors. An idle object placed directly underneath spout will immediately activate
faucet.
Remove hands and water will cease to flow within 1-3 seconds.
If hands are left underneath spout for 30 or 60 seconds, water will automatically shut off. To initiate flow a ain move hands away
from faucet and start at step 1.
When attempting to run water over small objects such as a tooth brush, it may be necessary
to bring object closer to sensor to initiate water flow, when water begins to flow, move
object back under stream of water. nce user “gets the feel” of the faucet this step may be
skipped.