Madison RS-094-MK5 Manual

Leak Detection & Automatic Shut-Off System
for Conventional Vent Gas Water Heaters
with Gas Flow Interrupter
Congratulations on your purchase of a FloodMaster RS-094-MK5 water heater leak detection
system from Reliance Detection Technologies. This product is designed to automatically shut
off the water supply to a water heater or tank if a leak is detected. This kit also provides output
signal capabilities to shut down gas ow when a leak is detected.
To ensure proper installation and to maximize the performance of your RS-094-MK5 water leak
detection system, please read this manual thoroughly before installing or operating the system.
PLEASE READ CAREFULLY BEFORE PROCEEDING:
If a leak is detected, the RS-094-MK5 will shut off the water going to the water heater. This will
stop the continuous ow of water from the water supply to the tank. However, all or some of
the water that is already in the tank may still leak out onto the oor.
NOTE: This installation and operating manual contains important information about the operation of the
RS-094-MK5 system. If this system is being installed for use by a different user, please be sure a copy of
this manual is left with the system for future reference.
www.RelianceDetection.com Toll-Free: 888-771-4929
RS-094-MK5 System Components (included in kit):
1 – Receiver box / actuator
1 – 3/4” full port lead-free shut-off valve
(NSF/ANSI 61 and 372)
1 – Power supply with 12’ lead wire
1 – Water sensor with 8’ lead wire
1 – Metal plate for sensor placement
1 – Gas ow interrupter
RS-094-MK5

NOTE: The RS-094-MK5 can be installed on existing or new water heater installations.
RDT recommends installation by appropriately licensed and certied installers to ensure that all
local code requirements are met.
INSTALLATION INSTRUCTIONS
1. Turn off the water supply feed line to the water heater.
2. Prior to installation, manually exercise the valve body to fully closed and back to fully open
position by holding it in your hand, applying a pliers to the valve stem and turning. Thread the valve
body into the feed water line after the manual shut-off. Apply pipe sealant or Teon®tape to the
NPT threads and tighten.
3. The receiver connector comes prewired with basic connections to the power supply, sensor and
gas ow interrupter. Using an appropriate screwdriver, make any additional electrical connections
as may be desired for output contacts or additional sensors per wiring Figure 2. (Note: additional
sensors can be connected to either 6 & 7 or 8 & 9, as wiring space allows.) Then snap the terminal
wiring block into the receiver housing at the mating slot provided.
4. Secure the valve body in one hand and snap the receiver into place on the valve body mounting
pad. (Note: Improper alignment of the valve stem may interfere with proper receiver mounting. If any
resistance is encountered, conrm the witness mark on the valve stem is in alignment with the valve
ports. Use an appropriate hand tool, such as pliers, to clamp down on the valve stem and turn in the
appropriate direction until the desired position is achieved).
5. Place the sensor(s) where water is most likely to rst accumulate (such as the drain pan or the
oor next to the tank). The sensor is magnetic and can be installed horizontally or vertically in
conjunction with the metal plate – see Figure 3.
• Clean the desired location area to ensure the surface is clean for optimum plate adhesion.
• Peel the backing off the metal plate to reveal the adhesive and stick in place.
• Place the sensor on the plate as close as possible to the oor, allowing the magnets to secure it
in place.
Note: The sensor features a through-hole that can be used to screw it onto a surface if a more
permanent installation is desired or necessary.
6. Shut off the gas supply and shut down the water heater per the manufacturer’s instructions.
7. Disconnect the thermocouple at the gas control connection. Insert the gas ow interrupter and
reconnect the thermocouple.
8. Plug the power supply into a 120V AC wall outlet. The green “Power” indicator light on the receiver
will turn on.
9. Turn on the gas supply and light the pilot on the water heater per the water heater manufacturer’s
instructions. Open the water supply feed line.
10. Function Test the system as follows:
• Place the sensor on a wet paper towel. The audible alarm will sound and the valve will rotate to
the closed position. The gas ow interrupter will also respond to close down the gas ow to the
water tank.
• The red “Valve Closed” LED will turn on when the valve is completely closed (approximately
45-second cycle time). Open a hot water faucet and conrm that there is no water ow. Conrm
deactivation of the gas.
• Remove the sensor from the paper towel, dry the contact points, and place it back in the desired
location on the metal plate.
• Press and release the “Reset” button on the receiver to open the valve and begin the ow
of water again (approximately 45 seconds to fully re-open). The green “Power” indicator light will
ash once to indicate the reset process has begun. Relight the water heater pilot and conrm
gas ow to the water heater.
• Open a hot water faucet and inspect for water ow.

RS-094-MK5
WATER
HEATER KIT
1. Receiver box
2. Valve Closed LED
3. Power LED
4. Wiring terminal block
5. Reset button
6. Valve actuator
7. Water sensor
8. Metal plate
9. Shut-off valve
10. Power transformer
11. Gas ow interrupter
4
3 5
3.0
3.1
1.53.0
1.4
2.5
.4
1.4
1.11.350
4.9
1FRONT VIEW BACK VIEW
2
6
2.56
Ø .12 THRU
1.77
.02
1.48
1.69
8 FT LEAD
.30
.04
PIN OFFSET
FROM SURFACE
Ø .25 .30
Ø .38 x 82°
7
8
9
See RS-094 technical data submittal
sheet for valve dimensions.
FIGURE 2 –
WIRING DIAGRAM
FIGURE 3 –
SENSOR INSTALLATION OPTIONS
11
POWER SUPPLY
RS-094
123456789
GREEN
GREEN
FIGURE 1
KIT PREWIRED AT FACTORY
1.89
12 FT LEAD
10
HORIZONTAL VERTICAL

All specications subject to change without notice.
© Copyright 2020 Reliance Detection Technologies, LLC – A Madison Company
ECN # 11386, 09/2020, MF106, RevB
203-488-2684 or 888-771-4929
www.RelianceDetection.com
27 Business Park Drive, Branford, CT 06405
NEED INSTALLATION OR SETUP ASSISTANCE?
Call toll-free: 888-771-4929
www.RelianceDetection.com/support/RS-094
Warning: For use with water only. Do not install on gas line. Never install this device
on a re protection or re suppression system. For indoor use only.
OUTPUT SIGNAL CONNECTIONS
The unit also provides output signal capabilities (SPDT Relay Output Contact) for connection to a home
security panel or for use with an appropriate relay to control a secondary device, such as a pump. See
Figure 2 for wiring diagram.
Normally Closed Circuit – Terminal Pins 3 & 4 Normally Open Circuit – Terminal Pins 4 & 5
OPERATION & SYSTEM RESET
In the event the system activates, locate the source of the leak, remove the sensor from the water and
dry the metal contacts on the bottom. Correct the problem causing the leak and replace the sensor in
the desired leak detection location once again as required. Press and release the “Reset” button on the
receiver to open the valve and begin the ow of water again. The green “Power” indicator light on the
receiver will ash once to conrm the reset. Light the water heater pilot and conrm gas ow to the
water heater.
MAINTENANCE
Test the system annually per the function test (install step 10) to ensure correct operation and maintain
product warranty status. At a minimum, exercise (press and release) the “Reset” button on the receiver.
EMERGENCY MANUAL VALVE OPERATION
The unit is equipped with an emergency feature for the manual rotation of the valve. Disengage the
actuator from the valve and manually changing the valve to open or closed as follows:
1. Turn off the main power to the transformer.
2. Stabilize the water feed line by grabbing it in one hand near the valve. While grasping the actuator
housing in the other hand, pull the actuator housing away from the water feed line.
3.
Using an appropriate hand tool (such as a pliers), clamp down on valve stem and turn in the appropriate
direction until the desired position is achieved. Note the top of the stem is slotted to indicate valve
position (in line with water ow indicates open valve; slot across water line indicates closed).
4. Before remounting the actuator, return the valve to the original position prior to the manual rotation.
5. Remount the actuator and restore the main power to the transformer.
6. Test for correct operation per the function test listed in install step 10.
Table of contents
Popular Security Sensor manuals by other brands

3M
3M Nano-Lok Edge Series instruction manual

Motorola
Motorola HMDS1040 - Xanboo Home Monitoring quick start guide

PCB Piezotronics
PCB Piezotronics ICP 102A08 Installation and operating manual

Comelit
Comelit SD01B Technical manual

LEGRAND
LEGRAND CP Electronics MWS3A-KNX installation guide

Lutron Electronics
Lutron Electronics LOS-W Series installation instructions

ORORO
ORORO HEATED JACKET/HOODIE manual

Rielta
Rielta STEKLO-3 installation guide

RectorSeal
RectorSeal AQUAGUARD 4200E installation instructions

Satel
Satel OPAL user manual

jablotron
jablotron JA-181M quick start guide

Novar ED&S
Novar ED&S Wireless Passive Infra-Red Movement Detector Installation and operating instructions