Magnetic PULT01 User manual

PULT01 / PULT02
Desk panels for barriers and pedestrian gates
PULT01
Desk panel 1-
channel
PULT02
Desk panel 2-
channel
The desk panels PULT01 / PULT02 are used for manual control of barriers and / or pedestrian gates, e.g. from a
porter's lodge or from a reception. The 1-channel version PULT01 can control only one barrier or one pedestrian
gate, with PULT02 two independent barriers or pedestrian gates or also a combination of a barrier and a
pedestrian gate can be controlled.
A sheet with standardised sticker symbols is supplied. This can be used to paste over the membrane buttons if
another function is to be switched with it. White blank stickers are also supplied, with which the membrane
buttons can also be labelled using a waterproof pen if required.
Technical data
Characteristic
Value
Notice
Number of channels
PULT 01 = 1-channel
PULT 02 = 2-channel
Power supply,
separate for each
channel
24 V DC ± 10 %
Reverse polarity protection by diode
Number of buttons
per channel
4
2 simple push buttons,
2 push buttons with memory function
Number of inputs per
channel
2 pieces, 24V DC
Indication of status via LED
Number of outputs
per channel
5 pieces, 24 V DC
Number of LED per
channel
5 pieces
Dimensions
L x W x H
165 x 90 x 48 mm
IP protection
IP 65
Connection cable
10-core, 3 m length
Standards EMC
EN61000-6-2
EN61000-6-3

Control and display elements
Button S1:
Works like a multi-stage switch. By pressing several times, one of two outputs (OUT1/OUT2) is cyclically switched
on, then both outputs are switched off. The associated LEDs P1 and P2 indicate the switching status of the two
outputs.
Initial position at start-up: Outputs off
Power failure: Previous switching state remains after voltage recovery
Button S2:
Works like an ON/OFF switch. Pressing once switches the output (OUT3) on, pressing a second time switches it off
again, etc. The corresponding LED P3 indicates the switching status of the output.
Initial position at start-up: Output off
Power failure: Previous switching state remains after voltage recovery
Buttons S3 and S4:
Simple push buttons without memory function. The corresponding output (OUT4/OUT5) is switched on as long as
the respective button is pressed.
LED P4 and P5:
The two LEDs are switched via one input (IN1/IN2) each. They are located near the two buttons S3 and S4, but
unlike P1 to P3, they are not permanently coupled to the buttons. This means that a completely different
feedback can be given via P4 and P5 than to the functions that are switched via the S3 and S4 buttons.
Power supply:
The desk panels must be operated with 24V (VCC/GND). The polarity must be observed.
With PULT 02, the two channels are galvanically separated from each other so that two barriers or pedestrian
gates or a combination of both can be operated independently of each other.
Technology:
Each channel is controlled by a separate microcontroller.

Use with barriers and pedestrian gates
For MHTM™ MicroDrive barriers and FlowMotion™ products, the desk panel is connected to the control unit MGC
/ MGC Pro. Please also refer to the circuit diagram supplied with the desk panels.
The desk panels can also be used with older barriers, e.g. with control unit MLC10 or MUB3. They can also be
used for pedestrian gates with control unit MBC110 / 111, e.g. MPP, MPS.
The functionalities described in following show only a part of the possible switching functions.
The available buttons and displays can be individually assigned and thus adapted to different customer
requirements.
Functionality with MHTM™ MicroDrive barriers
With a desk panel PULT01, one barrier can be operated, with a PULT02, two barriers can be operated via three
separate buttons each. For this, the barriers must be set to either operating mode 4 (two-pulse control) or
operating mode 2 (deadman).
Button
Button S1: With barriers being
freely available
Button S2: Permanent-OPEN
Button S3: Open barrier
Button S4: Close barrier
Display LED
LED P1 / P2: Depending on the
function of button S1
LED P3: Display permanent-
OPEN activated
LED P4: Display barrier opened
LED P5: Display barrier closed
Operating mode 4 (2 buttons, typical porter operation):
Button S1 and the two LEDs P1 and P2 are not normally required for barriers, but can be used for other
functions.
By briefly pressing button S2, the barrier can be opened and held in the open position (permanent-OPEN).
A closing signal is then ignored. The status permanent-OPEN is indicated via LED P3. Pressing button S2
again briefly switches off the permanent-OPEN function, LED P2 goes out. The barrier can then be closed
again via a closing signal.
The barrier can be opened by briefly pressing button S3 if no closing signal is present.
The barrier can be closed by briefly pressing button S4 if there is no permanent-OPEN signal.
Important notice: The logical state of buttons S1 and S2 is saved each time the button is pressed. After a power
failure, the outputs of S1 and S2 return to the same state as before the power failure. The status of buttons S3
and S4 is not saved.

Operating mode 2 (deadman):
This operating mode differs from operating mode 2 in that the buttons S3 or S4 must be kept pressed until the
barrier boom has reached the respective end position. If the respective button is released before reaching the
end position, the barrier boom stops moving. The function permanent-OPEN works in the same way as in
operating mode 4.
Connection cable
A 10-core cable is required between the barrier and the desk panel. To ensure functional safety between the
control unit and the desk panel, a cable cross-section of at least 0.5 mm² must be laid for a maximum cable length
of 100 metres.
There are 3-metre long, flexible connection cables on the desk panels. With PULT02 there are two separate
cables. The cables can be extended on site using junction boxes if required.
Replacement for previous desk panels PG01 to PG04
A desk panel PULT01 or PULT02 can replace an old desk panel PG01 or PG02. If PG03 or PG04 are to be replaced,
two panels must be used.
It must be noted that only control units that are operated with a 24V supply can be used with PULT01 or PULT02.
Any special solutions that were supplied with other operating voltages are therefore not possible.
It should also be noted that the switch for "permanent-OPEN" used on the desk panels PG01 to PG04 is no longer
wired internally in parallel with the "Barrier OPEN" button. Instead, the output that is switched with button S2
(permanent-OPEN) must be wired to an input with the function "Open high priority".
The switching state of button S2 is stored in the event of a power failure, so the button behaves in the same way
as the previous solution with a "permanent-OPEN" switch.

Functionality with MHTM™ FlowMotion™
A desk panel PULT01 can be used to operate one pedestrian gate, and a PULT02 can be used to operate two
pedestrian gates, each via 4 separate buttons. A large number of possible functions can be switched and
displayed with one desk panel.
mTripod / mSwing / mWing
The buttons and the associated LEDs can be assigned individually according to customer requirements.
Below you will find a possible example for the use of a desk panel PULT01 / 02 with a mWing. Alternatively, you
could also assign the function "Illumination off" or "Inhibit opening" to button S2, for example.
Button
Button S1: press several times
Position 0 = normal operation
Position 1 = permanent open R1
Position 2 = permanent open R2
Button S2: Switch on random
check function / confirm hits
Button S3: Open individually in
direction R1
Button S4: Open individually in
direction R2
Display LED
LED P1: Permanent open R1 active
LED P2: Permanent open R2 active
LED P3: Display “Random check
function" switched on
LED P4: briefly lights up when a
person has passed through from
direction R1
LED P5: briefly lights up when a
person has passed through from
direction R2
Button S1: In the initial position (switch position 0), LED P1 and LED P2 are not illuminated. The mWing is
in normal operation (opening by validation or signal on button S3 or S4). Press once to switch to switching
position 1. The mWing is now operated permanent open for direction R1, the associated LED P1 lights up.
Pressing button S1 again switches to switching position 2. The mWing is now operated permanent open
for direction R2, the associated LED P2 lights up. Press again to return to the initial position and the
mWing returns to normal operation.
The random check function can be switched on by briefly pressing button S2. The corresponding LED P3
then lights up. Pressing it again switches the random check function off again. If a random hit has been
triggered by the random check function (external light / siren is on), the hit must be confirmed by
pressing button S2 twice (external light / siren off again).
By briefly pressing button S3, a passage open can be given for a person in the direction of R1. LED P4
lights up when a person has passed through in the direction of R1.
By briefly pressing button S4, a passage open can be given for a person in the direction of R2. LED P5
lights up when a person has passed through in the direction of R2.
Important notice: The logical state of buttons S1 and S2 is saved each time the button is pressed. After a power
failure, the outputs of S1 and S2 return to the same state as before the power failure. The status of buttons S3
and S4 is not saved.
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

PlugTech
PlugTech MBC-NULL operating instructions

Siemens
Siemens RC 195 installation instructions

DAB
DAB SMART PRESS WG 1,5HP User manual instructions for installation and maintenance

Logitech
Logitech TAP IP Setup guide

Sorel
Sorel TDC 4 Installation and operating instructions

CHERUBINI
CHERUBINI MyRoll instructions

m-Dimension
m-Dimension D3208 user guide

London Electronics
London Electronics INT-T Connection details, scaling and general information

Mitsubishi Electric
Mitsubishi Electric MELSEC Q Series user manual

ARM Solar
ARM Solar ARM-L-1512 Quick installation guide

DT Research
DT Research DT136HU Basic operation guide

Swagelok
Swagelok LBS4 user manual