Functionality with MHTM™ FlowMotion™
A desk panel PULT01 can be used to operate one pedestrian gate, and a PULT02 can be used to operate two
pedestrian gates, each via 4 separate buttons. A large number of possible functions can be switched and
displayed with one desk panel.
mTripod / mSwing / mWing
The buttons and the associated LEDs can be assigned individually according to customer requirements.
Below you will find a possible example for the use of a desk panel PULT01 / 02 with a mWing. Alternatively, you
could also assign the function "Illumination off" or "Inhibit opening" to button S2, for example.
Button
Button S1: press several times
Position 0 = normal operation
Position 1 = permanent open R1
Position 2 = permanent open R2
Button S2: Switch on random
check function / confirm hits
Button S3: Open individually in
direction R1
Button S4: Open individually in
direction R2
Display LED
LED P1: Permanent open R1 active
LED P2: Permanent open R2 active
LED P3: Display “Random check
function" switched on
LED P4: briefly lights up when a
person has passed through from
direction R1
LED P5: briefly lights up when a
person has passed through from
direction R2
Button S1: In the initial position (switch position 0), LED P1 and LED P2 are not illuminated. The mWing is
in normal operation (opening by validation or signal on button S3 or S4). Press once to switch to switching
position 1. The mWing is now operated permanent open for direction R1, the associated LED P1 lights up.
Pressing button S1 again switches to switching position 2. The mWing is now operated permanent open
for direction R2, the associated LED P2 lights up. Press again to return to the initial position and the
mWing returns to normal operation.
The random check function can be switched on by briefly pressing button S2. The corresponding LED P3
then lights up. Pressing it again switches the random check function off again. If a random hit has been
triggered by the random check function (external light / siren is on), the hit must be confirmed by
pressing button S2 twice (external light / siren off again).
By briefly pressing button S3, a passage open can be given for a person in the direction of R1. LED P4
lights up when a person has passed through in the direction of R1.
By briefly pressing button S4, a passage open can be given for a person in the direction of R2. LED P5
lights up when a person has passed through in the direction of R2.
Important notice: The logical state of buttons S1 and S2 is saved each time the button is pressed. After a power
failure, the outputs of S1 and S2 return to the same state as before the power failure. The status of buttons S3
and S4 is not saved.