Manitowoc LuminIce K-00424 Instructions for use

Installation, Use & Care Manual
America’s #1 Selling Ice Machine
This manual is updated as new information and models are released.
Visit our website for the latest manual. www.manitowocice.com
This manual contains English and French text
LuminIce™
Manitowoc
Part Number 000008463 10/11

Table of Contents
2Part Number 000008463 10/11
Section 1
General Information Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
LuminIce™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Section 2
Installation Instructions
LuminIce™ Installation 30" Wide Single Evaporator Models . . . . . . . . . . . . . . . . 5
LuminIce™ Installation 48" Wide Single Evaporator Models . . . . . . . . . . . . . . . . 7
LuminIce™ Installation Two Evaporator Ice Machines . . . . . . . . . . . . . . . . . . . . . 10
LuminIce™ Reminder Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Section 3
Customer Support Cleanup Procedure for Accidental Bulb Breakage . . . . . . . . . . . . . . . . . . . . . . . . 13
Before Cleanup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
During Cleanup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
After Cleanup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cleanup Steps for Hard Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Cleanup Steps for Carpeting or Rugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Future Cleaning of Carpeting or Rugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Part Number 000008463 10/11 3
Section 1
General Information
This manual covers installation of the LuminIce™ on the
following ice machine models:
Kit K00424 is used with 22" & 30" wide single
evaporator models (i0300 through i1000)
Kit K00434 is used with all 48" wide or dual
evaporator models
Before You Begin
Remove all packing material and inspect the equipment
for concealed shipping damage. If damage is found,
notify the shipper immediately.
LuminIce™ is for use on Indigo™ ice machines and is
not compatible with previous series ice machines.
Self-Contained
Air-Cooled Self-Contained
Water-Cooled Remote
Condenser
QuietQube
Remote
Condensing
Unit
ID0302A
IY0304A ID0303W
IY0305W ----
---- ----
----
ID0322A
IY0324A ID0323W
IY0325W ----
---- ----
----
ID0452A
IY0454A ID0453W
IY0455W ----
---- ----
----
IR0500A
ID0502A
IY0504A
IR0501W
ID0503W
IY0505W
IR0590N
ID0592N
IY0594N
----
----
----
IR0520A
ID0522A
IY0524A
IR0521W
ID0523W
IY0525W
----
----
----
----
----
----
ID0602A
IY0604A ID0603W
IY0605W ID0692N
IY0694N ID0682C
IY0684C
IB0694YC
IR0850A
ID0852A
IY0854A
IR0851W
ID0853W
IY0855W
IR0890N
ID0892N
IY0894N
ID0872C
IY0874C
IB0894YC
ID1002A
IY1004A ID1003W
IY1005W
ID1003WM
ID1092N
IY1094N ID1072C
IY1074C
IB1094YC
ID1202A
IY1204A ID1203W
IY1205W ---
--- ---
---
ID1402A
IY1404A ID1403W
IY1405W
ID1403WM
ID1492N
IY1494N ID1472C
IY1474C
IR1800A
ID1802A
IY1804A
IR1801W
ID1803W
IY1805W
IR1890N
ID1892N
IY1894N
ID1872C
IY1874C
---- ---- ---- ID2172C
IY2174C
!
Warning
PERSONAL INJURY POTENTIAL
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given
supervision concerning use of the appliance by a
person responsible for their safety.

General Information Section 1
4Part Number 000008463 10/11
LuminIce™
The LuminIce™ growth inhibitor recirculates the air in
the ice machine foodzone over a UV bulb. This process
will inhibit the growth of common micro-organisms on all
exposed foodzone surfaces.
• LuminIce™ bulbs require replacement on a yearly
basis. Although the bulb will still illuminate after 12
months, the effectiveness of the bulb diminishes as
operational hours increase. To retain maximum
effectiveness, replace the bulb on a 12 month
schedule.
• The control board can be set to automatically display
a reminder after 12 months. Refer to Section 2
LuminIce™ setup procedure for full details.

Part Number 000008463 10/11 5
Section 2
Installation Instructions
LuminIce™ Installation 30" Wide Single
Evaporator Models
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. To allow access for LuminIce™ tubing, the
evaporator dust cover and plastic caps in the
evaporator and compressor compartment bulkhead
wall must be removed and discarded.
3. Assemble bracket to left-hand top rail with three
provided screws.
!Warning
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
Remove Plastic Caps From Bulkhead In The
Evaporator And Compressor Compartment
Mount Bracket With
Three Screws

Installation Instructions Section 2
6Part Number 000008463 10/11
4. Assemble LuminIce™ to bracket with three screws
provided. The bulb and bulb wiring must face toward
the rear of the ice machine to allow bulb
replacement with LuminIce™ in place.
5. Mount transformer on evaporator bulkhead above
control box. Attach supplied wire clip and route line
voltage wires through clip.
6. Route line voltage wires (Black & White) through line
voltage Heyco fitting and attach to L1 and L2
contactor terminals.
NOTE: QuietQube models do not have open terminals
on contactor. Remove two wires from contactor, install
supplied electrical connector and connect wires.
Attach With Three Screws
Route Line Voltage Wires Through Clip
Install Transformer Attach Wire Clip
Route Through Line Voltage Heyco
and
Attach to Contactor Terminals
LuminIce Power
L1
L2
Wires Removed From Contactor Contactor

Section 2 Installation Instructions
Part Number 000008463 10/11 7
7. Route low voltage wiring (black and yellow wires) to
the LuminIce™. Install wire clip and route wires
close to evaporator bulkhead to assure harness is
away from any moving parts, then snap wire
harness connectors together.
8. Install LuminIce™ hoses.
• Insert hose closest to the front of the ice machine in
the bottom evaporator bulkhead hole.
• Insert hose farthest from the front of the ice machine
in the upper evaporator bulkhead hole.
9. Install the notched evaporator dust cover from kit
and test run the ice machine and LuminIce™. The
Luminice™ is energized whenever power is applied
to the ice machine.
LuminIce™ Installation 48" Wide Single
Evaporator Models
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. To allow access for LuminIce™ tubing, the
evaporator dust cover and plastic caps in the
evaporator and compressor compartment bulkhead
wall must be removed and discarded. Remove the
evaporator dust cover to access lower cap.
Install wire clip and route wires
along evaporator bulkhead.
!Warning
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
Remove Plastic Caps From Bulkhead In The
Evaporator And Compressor Compartment
Remove Dust Cover

Installation Instructions Section 2
8Part Number 000008463 10/11
3. Remove bracket from ice machine and assemble
LuminIce™ and transformer to bracket. Attach
tubing and secure with hose clamps.
4. Assemble bracket to ice machine.
Mount LuminIce™ and
Transformer To Bracket

Section 2 Installation Instructions
Part Number 000008463 10/11 9
5. Route line voltage wires (Black & White) through line
voltage Heyco fitting and attach to L1 and L2
contactor terminals.
NOTE: Three phase models do not have open terminals
on contactor. Remove two wires from contactor, install
supplied electrical connector and connect wires.
6. Route LuminIce™ hoses to evaporator and attach.
• Insert hose closest to the front of the ice machine in
the bottom evaporator bulkhead hole.
• Insert hose farthest from the front of the ice machine
in the upper evaporator bulkhead hole.
7. Install the evaporator dust cover and test run the ice
machine and LuminIce™. The Luminice™ is
energized whenever power is applied to the ice
machine.
Route Through Line Voltage Heyco
and
Attach to Contactor Terminals
LuminIce Power
L1
N
Ice Machine Power Incoming Power Supply

Installation Instructions Section 2
10 Part Number 000008463 10/11
LuminIce™ Installation Two Evaporator Ice
Machines
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. To allow access for LuminIce™ tubing, the plastic
caps in the evaporator compartment bulkhead wall
must be removed and discarded. Cap located
behind evaporator will fall into the water trough.
Remove water trough to retrieve cap, then discard.
3. Cut hose to length.
• Cut one hose 8" (20 cm) long.
• Cut one hose 18" (46 cm) long.
4. Assemble LuminIce™.
• Assemble LuminIce™ to bracket.
• Install tubing and secure with hose clamps.
• Insert a tubing adapter into each hose.
NOTE: The bulb and bulb wiring must face toward the
top of the ice machine to allow bulb replacement with
LuminIce™ in place.
5. Attach Luminice™ assembly to corner post with two
screws.
6. Mount transformer to evaporator bulkhead.
!Warning
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
Remove Plastic Caps From
Evaporator Bulkhead

Section 2 Installation Instructions
Part Number 000008463 10/11 11
7. Route line voltage wires (Black & White) through line
voltage Heyco fitting. Disconnect LI & N wires and
install L1 & N of wiring adapter to the incoming
power supply wires. Connect removed wires and
LuminIce™ wires to adapter.
8. Remove four screws to allow access for low voltage
wire routing.
9. Route low voltage wiring (black and yellow wires) to
the LuminIce™, and snap wire harness connectors
together. Reinstall screws removed in previous step.
10. Install LuminIce™ hoses:
• Route bottom port LuminIce™ hose to rear
evaporator bulkhead hole.
• Route top port LuminIce™ hose to forward
evaporator bulkhead hole.
LuminIce Power
L1
N
Ice Machine Power
Incoming Power Supply
Remove four screws

Installation Instructions Section 2
12 Part Number 000008463 10/11
LUMINICE™ REMINDER SETUP
Perform the procedure below to display a change-bulb
reminder every 12 months. Complete display panel
navigation is available in the Indigo™ ice machine
Installation Use and Care Manual. Publications for all
Manitowoc equipment are available on our website
www.manitowocice.com.
1. From the Set-Up menu, use the Down arrow to
highlight LuminIce™.
2. Press the Checkmark. On this screen, you can
choose to turn the reminder to AUTO or OFF by
highlighting your choice and pressing the
Checkmark. Selecting one will deselect the other.
3. When the check reflects your preference, use the
Down arrow to navigate to Exit and press the
Checkmark. The display will return to the Set-Up
menu.

Part Number 000008463 10/11 13
Section 3
Customer Support
Cleanup Procedure for Accidental Bulb Breakage
The cleanup procedure is identical to the procedure
used to clean up compact fluorescent (CFL) or
fluorescent tube lights. These lights contain a small
amount of mercury sealed within a glass tube. Breaking
these types of lights will release mercury and mercury
vapor. The broken bulb can continue to release mercury
vapor until it is cleaned up and removed.
To minimize exposure to mercury vapor, the EPA
(Enviromental Protection Agency) recommends the
following cleanup and disposal steps.
This cleanup guidance represents the minimum actions
recommended to clean up a broken light containing
mercury, and will be updated if the EPA identifies more
effective cleanup practices.
The latest EPA procedures can be viewed on their
website at www.epa.gov/cfl/cflcleanup.html.
BEFORE CLEANUP
• Have people and pets leave the room, and avoid the
breakage area on the way out.
• Open a window or door to the outdoors and leave the
room open for 5 - 10 minutes.
• Shut off the central forced air heating/air conditioning
(H&AC) system.
• Collect materials you will need to clean up the broken
bulb:
A. Stiff paper or cardboard
B. Sticky tape (e.g., duct tape)
C. Damp paper towels or disposable wet wipes (for
hard surfaces)
D. Glass jar with a metal lid (such as a canning jar)
or a sealable plastic bag(s)
DURING CLEANUP
• Be thorough in collecting broken glass and visible
powder.
• Place cleanup materials in a sealable container.
AFTER CLEANUP
• Promptly place all bulb debris and cleanup materials
outdoors in a trash container or protected area until
materials can be disposed of properly. Avoid leaving
any bulb fragments or cleanup materials indoors.
• If practical, continue to air out the room where the
bulb was broken and leave the heating/air
conditioning system shut off for several hours.

Customer Support Section 3
14 Part Number 000008463 10/11
Cleanup Steps for Hard Surfaces
1. Carefully scoop up glass fragments and powder
using stiff paper or cardboard and place debris and
paper/cardboard in a glass jar with a metal lid. If a
glass jar is not available, use a sealable plastic bag.
NOTE: Since a plastic bag will not prevent the mercury
vapor from escaping, remove the plastic bag(s) from the
home after cleanup.
2. Use sticky tape, such as duct tape, to pick up any
remaining small glass fragments and powder. Place
the used tape in the glass jar or plastic bag.
3. Wipe the area clean with damp paper towels or
disposable wet wipes. Place the towels in the glass
jar or plastic bag.
NOTE: Vacuuming of hard surfaces during cleanup is
not recommended unless broken glass remains after all
other cleanup steps have been taken. It is possible that
vacuuming could spread mercury containing powder or
mercury vapor, although available information on this
problem is limited.
If vacuuming is needed to ensure removal of all broken
glass, keep the following tips in mind:
• Keep a window or door to the outdoors open.
• Vacuum the area where the bulb was broken using
the vacuum hose, if available; and remove the
vacuum bag (or empty and wipe the canister) and
seal the bag/vacuum debris, and any materials used
to clean the vacuum, in a plastic bag.
• Promptly place all bulb debris and cleanup materials,
including vacuum cleaner bags, outdoors in a trash
container or protected area until materials can be
disposed of properly.
• Check with your local or state government about
disposal requirements in your area. Some states and
communities require fluorescent bulbs (broken or
unbroken) be taken to a local recycling center.
• Wash your hands with soap and water after
disposing of the jars or plastic bags containing bulb
debris and cleanup materials.
• Continue to air out the room where the bulb was
broken and leave the H&AC system shut off, as
practical, for several hours.
Cleanup Steps for Carpeting or Rugs
1. Carefully scoop up glass fragments and powder
using stiff paper or cardboard and place debris and
paper/cardboard in a glass jar with a metal lid. If a
glass jar is not available, use a sealable plastic bag.
NOTE: Since a plastic bag will not prevent the mercury
vapor from escaping, remove the plastic bag(s) from the
home after cleanup.
2. Use sticky tape, such as duct tape, to pick up any
remaining small glass fragments and powder. Place
the used tape in the glass jar or plastic bag.
NOTE: Vacuuming of hard surfaces during cleanup is
not recommended unless broken glass remains after all
other cleanup steps have been taken. It is possible that
vacuuming could spread mercury containing powder or
mercury vapor, although available information on this
problem is limited.
If vacuuming is needed to ensure removal of all broken
glass, keep the following tips in mind:
• Keep a window or door to the outdoors open.
• Vacuum the area where the bulb was broken using
the vacuum hose, if available; and remove the
vacuum bag (or empty and wipe the canister) and
seal the bag/vacuum debris, and any materials used
to clean the vacuum, in a plastic bag.
• Promptly place all bulb debris and cleanup materials,
including vacuum cleaner bags, outdoors in a trash
container or protected area until materials can be
disposed of properly.
• Check with your local or state government about
disposal requirements in your area. Some states and
communities require fluorescent bulbs (broken or
unbroken) be taken to a local recycling center.
• Wash your hands with soap and water after
disposing of the jars or plastic bags containing bulb
debris and cleanup materials.
• Continue to air out the room where the bulb was
broken and leave the H&AC system shut off, as
practical, for several hours.

Section 3 Customer Support
Part Number 000008463 10/11 15
FUTURE CLEANING OF CARPETING OR RUGS
1. Air Out the Room During and After Vacuuming.
2. The next several times you vacuum the rug or
carpet:
A. Shut off the H&AC system.
B. Close the doors to other rooms.
C. Open a window or door to the outside before
vacuuming.
D. Change the vacuum bag after each use in this
area.
E. After vacuuming is completed, keep the H&AC
system shut off and the window or door to the
outside open, as practical, for several hours.

Table des matières
16 Part Number 000008463 10/11
Section 1
Généralités Avant de commencer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LuminIce™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Section 2
Instructions d’installation
Installation du LuminIce™ pour les modèles à évaporateur unique
de 30 po de large . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installation du LuminIce™ pour les modèles à évaporateur unique
de 48 po de large . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Installation du LuminIce™ pour les machines à glaçons à
deux évaporateurs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Configuration rappel LuminIce™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Section 3
Service clientèle Procédure de nettoyage lors d’un bris accidentel de l’ampoule . . . . . . . . . . . . . 27
Avant le nettoyage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Durant le nettoyage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Après le nettoyage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Étapes de nettoyage pour les surfaces dures . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Étapes de nettoyage pour les moquettes ou tapis . . . . . . . . . . . . . . . . . . . . . . . . 28
Nettoyage futur des moquettes ou tapis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Part Number 000008463 10/11 17
Section 1
Généralités
Ce manuel traite de l’installation du LuminIce™ pour les
modèles de machines à glaçons suivants :
La trousse K00424 est utilisée avec les modèles à
évaporateur unique de 22 po et 30 po de large
(i0300 jusqu’à i1000)
La trousse K00434 est utilisée pour les modèles de
48 po de large ou pour les modèles à double
évaporateur
Avant de commencer
Enlever toutes les matières d’emballage et inspecter
l’équipement pour tous dommages dissimulés dus au
transport. Si dommages, aviser immédiatement
l’expéditeur.
LuminIce™ est utilisé sur les machines à glaçons
Indigo™ et n’est pas compatible avec les machines à
glaçons des séries précédentes.
Autonome
refroidi à l’air Autonome
refroidi à l’eau Condenseur à
distance
Unité de
condensationà
distance
QuietQube
ID0302A
IY0304A ID0303W
IY0305W ----
---- ----
----
ID0322A
IY0324A ID0323W
IY0325W ----
---- ----
----
ID0452A
IY0454A ID0453W
IY0455W ----
---- ----
----
IR0500A
ID0502A
IY0504A
IR0501W
ID0503W
IY0505W
IR0590N
ID0592N
IY0594N
----
----
----
IR0520A
ID0522A
IY0524A
IR0521W
ID0523W
IY0525W
----
----
----
----
----
----
ID0602A
IY0604A ID0603W
IY0605W ID0692N
IY0694N ID0682C
IY0684C
IB0694YC
IR0850A
ID0852A
IY0854A
IR0851W
ID0853W
IY0855W
IR0890N
ID0892N
IY0894N
ID0872C
IY0874C
IB0894YC
ID1002A
IY1004A ID1003W
IY1005W
ID1003WM
ID1092N
IY1094N ID1072C
IY1074C
IB1094YC
ID1202A
IY1204A ID1203W
IY1205W ---
--- ---
---
ID1402A
IY1404A ID1403W
IY1405W
ID1403WM
ID1492N
IY1494N ID1472C
IY1474C
IR1800A
ID1802A
IY1804A
IR1801W
ID1803W
IY1805W
IR1890N
ID1892N
IY1894N
ID1872C
IY1874C
---- ---- ---- ID2172C
IY2174C
!Avertissement
RISQUE DE BLESSURES CORPORELLES
Ne pas utiliser un équipement qui a été mal utilisé,
abusé, négligé, endommagé ou dont les
spécifications originales de fabrication ont été
altérées/modifiées. Cet appareil ne doit pas être
utilisé par des personnes (enfants y compris) ayant
des capacités physiques, sensorielles ou mentales
diminuées, ou ayant un manque d’expérience et de
connaissance, à moins que celles-ci n’aient reçu
une formation sur l’utilisation de l’appareil par une
personne responsable de leur sécurité.

Généralités Section 1
18 Part Number 000008463 10/11
LuminIce™
L’inhibiteur de croissance LuminIce™ fait circuler l’air
dans la zone alimentaire de la machine à glaçons sur
une ampoule UV. Ce procédé entravera la croissance de
micro-organismes communs sur toutes les surfaces
exposées de la zone alimentaire.
• Les ampoules LuminIce™ doivent être remplacées
sur une base annuelle. Même si l’ampoule illuminera
encore après 12 mois, l’efficacité de l’ampoule
diminue au fur et à mesure que les heures de
fonctionnement augmentent. Pour garder une
efficacité maximale, remplacer l’ampoule tous les
12 mois.
• Le tableau de commande peut être réglé pour
afficher automatiquement un rappel après 12 mois.
Se référer à la Section 2 Configuration rappel
LuminIce™ pour des détails complets.

Part Number 000008463 10/11 19
Section 2
Instructions d’installation
Installation du LuminIce™ pour les modèles
à évaporateur unique de 30 po de large
1. Débrancher tout courant vers la machine à glaçons
au niveau du disjoncteur.
2. Pour permettre l’accès à la tubulure LuminIce™, le
couvercle anti-poussière de l’évaporateur et les
capuchons en plastique dans la cloison du
compartiment de l’évaporateur et du compresseur
doivent être enlevés et jetés.
3. Assembler le support sur le rail supérieur de gauche
avec les trois vis fournies.
!Avertissement
Débrancher le courant vers la machine à glaçons au
niveau du disjoncteur. Appuyer sur le bouton
d’alimentation n’enlève pas la tension sur la ligne.
Enlever les capuchons en plastique de la cloison dans le
compartiment de l’évaporateur et du compresseur.
Monter le support
avec les trois vis.

Instructions d’installation Section 2
20 Part Number 000008463 10/11
4. Assembler le LuminIce™ sur le support à l’aide des
trois vis fournies. L’ampoule et le fil de l’ampoule
doivent faire face à l’arrière de la machine à glaçons
pour permettre le remplacement de l’ampoule avec
le LuminIce™ en place.
5. Monter le transformateur sur la cloison de
l’évaporateur au dessus du boîtier de commande.
Attacher la broche d’agrafe fournie et acheminer les
fils de tension de secteur à travers l’agrafe.
6. Acheminer les fils de tension de secteur (Noir et
Blanc) à travers l’embout de tension de secteur
Heyco et attacher aux bornes de contacteur L1 et
L2.
REMARQUE : Les modèles QuietQube n’ont pas de
bornes ouvertes sur le contacteur. Enlever les deux fils
du contacteur, installer le connecteur électrique fourni et
raccorder les fils.
Attacher avec les trois vis
Acheminer les fils de tension de secteur à travers
Installer le
transformateur Attacher la
broche d’agrafe
Acheminer à travers la tension de secteur Heyco
et
Attacher aux bornes de contacteur
Alimentation LuminIce
L1
L2
Fils enlevés du contacteur Contacteur
This manual suits for next models
1
Table of contents
Languages: