For more information visit www.marcobeveragesystems.com
FRIIA COLD
CHILLERFONTSPACKAGING
FRIIA C FRIIA C TALL FONT DIMS
> Sleek and stylish alternative
to bottled or POU water
> Two font heights available
NAME
ORDER CODE
DIMENSIONS INC. DRIP TRAY
(D X W X H mm)
DIMENSIONS EXCL. DRIP TRAY
(D X W X H mm)
TAP TO COUNTER
(mm)
1b Una Font
1000859 168 x 120 x 287 138 x 30 x 287 233
1b Una Font Tall
1000858 168 x 120 x 345 138 x 30 x 345 291
345
138
291
287
138
233
ITEM PACKAGING DIMENSIONS
(L x W x H mm) WEIGHT
Fonts (all) 290 x 570 x 215 1.65kg
Chiller 500 x 320 x 520 31kg
FRIIA components (font
and chiller) are packed and
shipped in individual boxes.
PLEASE
NOTE
ORDER CODES (Complete bundle)
> FRIIA C 5000860
> FRIIA C Tall 5000863
CHILLER SYSTEM SET-UP
PRODUCT INFO SIZE PERFORMANCE SPECS PLUMBING, ELECTRICAL AND TECHNICAL SPECS
NAME
ORDER CODE
DIMENSIONS
(D X W X H mm)L/HR CUPS
/HR
POWER
@220v
PLUMBING
REQS
COMPRESSOR
POWER CHARGE REFRIGERANT
Chiller
1000860 436 x 259 x 455
30-40l/hr based on incoming
water temp of 15°C and
output water temp of 5-7°
175-235
(ΔT =
10 °C)
180 W 3/4” BSP 1/8hp 45g R290
For more information visit www.marcobeveragesystems.com
RADIUS OF MAXIMUM FONT PLACEMENT
COUNTER CUT-OUTS
4”/100mm
For drip-tray only
1.25”/32mm
3.25”/82.5mm
6.6”/168mm
VENTILATION
OR OR
23.6”/600mm
Standard
800mm high
cabinet
3.1”/80mm
11.8”/300mm
10.2”/260mm
2.5”/
65mm
1.9”/50mm
2.5”/
65mm
10.4”/265mm
10.4”/265mm 1.9”/50mm
2.5”/65mm
It is essential to allow for two ventilation points when installing FRIIA. Vents are not supplied. Where possible,
we recommend removing the back of your cabinet.
PLEASE
NOTE
CABINET
Min: 800mm (h) x 600mm (w) x 600mm (d) with 100mm clearance
around machines all sides
OPERATING ENVIRONMENT
Cannot exceed temperature of 35°C
FRIIA SYSTEM OVERVIEW
For more information visit www.marcobeveragesystems.com
SANITISATION
ACCESSORIES
Sanitisation Kit: Internal Water Cooler Sanitising Solution 1L + Chiller Best Service Cartridge 8000900
Internal Water Cooler Sanitising Solution 1L 8800125
Scaleclean 1kg Descaler (5 uses) 8000260
Chiller Best Service Cartridge 8000522
Scaleclean 200g Descaler (1 use) 8000270
50
45
40
35
30
25
20
15
10
5
0
Output Temp 3°C Output Temp 5°C Output Temp 7°C
1510 20 25 28 30 35 40
FRIIA OUTPUT VOLUME
Based on flow rate of 1.4L/min and ambient temperature of 20-25°C. Chart indicates FRIIA
chilling capacity based on incoming water temperature and desired output water temperate.
INCOMING TEMPERATURE (°C)
OUTPUT VOLUME (L/H)
> Wipe down font daily with non-abrasive cleaner.
> Sanitise the system every 6 months, after a filter change or after a period of inactivity (more than 72 hours)
HOW TO
CLEAN FRIIA
> We recommend use of both HOT (scale reducing filter if limescale is present) and COLD (carbon
block for taste and odour) water filters for FRIIA. Please contact us for advice on the best water filter.
> Descale the MIX boiler if scale is present in the water.
MAINTENANCE
FRIIA PERFORMANCE AND MAINTENANCE
For more information visit www.marcobeveragesystems.com
FRIIA C & FRIIA CS & FRIIA C HANDS-FREE
FRIIA C/ FRIIA CS /FRIIA C HANDS-FREE
COUNTER CUT-OUT WITH DRIP TRAY
FRIIA C 5000860
FRIIA C Tall 5000863
FRIIA C Hands-Free 5000857
FRIIA CS 5000862
FRIIA CS Tall 5000865
VENTILATION REQUIREMENTS
FRONT VENTILATION: Ventilation grilles cut out of standard cabinet door.
SIDE VENTILATION: Ventilation grilles cut out of standard 600mm
cabinet. Grilles may be fitted on either side as long as they ventilate
into an open unobstructed area.
BASE VENTILATION: Ventilation grilles cut in base panel and base
plinth, a grille must also be cut out at the top of the cabinet.
• At least 2 x vents 260mm/10.2” w x 65mm/2.5 h
• The cabinet may be ventilated in many ways provided there are cut
outs placed near the base and another near the top of the cabinet
to take advantage of natural circulation.
UNPACKING INSTRUCTIONS
• The chiller must be handled only in a vertical position. Transporting
the appliance in a horizontal position can cause severe damage to
the refrigerator.
• Remove the exterior and interior packing. Packing materials
(especially any plastic bags) should be stored out of the reach
of children, as a potential source of danger. When disposing
packaging parts, please follow current regulations on the matter,
separating carton from plastic parts.
• Always check that the equipment that is delivered corresponds to
the model indicated in the accompanying document.
• The equipment is shipped in a cardboard box. Once the packaging
has been removed, check the equipment has not been damaged in
transit; if damage is found, notify the carrier.
ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local regulations and
standards. The appliance is supplied with a moulded power cord. A
suitable mains power supply socket should be available within easy
access of the appliance so that it can be disconnected easily after install.
The standard machines are supplied with a UK 3-pin plug. For
EU models a 2-pin CEE-7 plug will be supplied. US models will be
supplied with the suitable plug. A suitable mains power supply socket
should be available within easy access of the appliance so that it
can be disconnected easily after install. The wires from the font are
terminated in a Mini Fit connector which will plug into a similar Mini Fit
connector mounted on the top lid of the undercounter boiler.
PLUMBING INSTALLATION PROCEDURE
• Ensure that the equipment is installed according to local plumbing
& water regulations.
• Fit a stop valve on a cold water line and attach a 3/4” BSP male
fitting, (eg. 3/4” x 1/2” 311 or washing machine type stop valve).
Suitable fittings are supplied with the kit to attach to the 3/4” BSP
fitting to connect the supplied 3/8” hose.
• Connect water supply lines following the installation drawings,
as per installation guide (starting page 14).
• In case filter systems are used verify that they satisfy the
requirements of the legislation in force.
• If the filter is new, turn on water and flush at least 10 litres
(2.5 gallon) through the filter before to connect it to the cooler;
if the filter is a used one, connect water inlet to the chiller.
• To ensure that the maximum value of pressure of 3 Bar is not
exceeded the chiller integrates a pressure reducer.
• Turn on the water to flush any impurities, dust etc from the inlet hose and
water pipe. Allow several litres through. Especially for new installations.
OPERATING THE CHILLER/CARBONATOR FOR THE
FIRST TIME
• Before connecting the appliance to the power source, let it stand upright
for approximately 2 hours. This will reduce the possibility of a malfunction.
• Check that all installation procedures have been carried out.
• Ensure water inlet is open.
• Before supplying power to the unit check water and Carbon Dioxide
lines do not leak.
• Plug the chiller into a suitable socket switch ON/OFF switch on the rear
of the chiller to ON position. The “Power ON Status” light will light-up.
• When the unit is on, the carbonation pump starts to fill. The
carbonation device stops when it reaches the maximum level.
• Once water and CO2 are connected, open the vent on top of the
Chiller by pulling the ring. This operation allows the escape of any air
bubbles present inside, which would affect the carbonation adversely.
• On the pressure reducer knob, adjust CO2 pressure to a value
between 50 and 65 PSI (350 and 450 kPa) (3.5 - 4.5 bar). This value
depends on the temperature of the water and on the ambient
temperature. The temperatures correspond to the CO2 pressure.
• To enable filling the lines, open the two lines in the following order:
cold sparkling water and cold natural water, until the flows appear
regular and without the presence of air, in each case deliver and
discharge at least 5 litres of water from each line.
• At this point you can dispense water.
369
437
600
600
100 min.
275
200
Applies to model(s) 1000850# & 1000851# (where # is blank, or one or more alphanumeric characters)
DRAWN BY
DWG NO.:
PANEL REMOVAL
DESCRIPTION:
PJT
20-08-14
187
C.O.
FRIIA Assembly (in cabinet)
31.5”/800mm
11.2”/
287mm
17.9”/
455mm
10.2”/259mm
13.5”/
345mm
4”/100mm
For drip-tray only
1.25”/32mm
3.25”/82.5mm
6.6”/168mm
Cold / Sparkling
Power
1401482
1400820
Cold/Sparkling
Water
2301251

This manual suits for next models

12

Other Marco Water System manuals

Marco UNA FONT User manual

Marco

Marco UNA FONT User manual

Marco MIX UC3 Guide

Marco

Marco MIX UC3 Guide

Marco FRIIA HC User manual

Marco

Marco FRIIA HC User manual

Marco FRIIA C User manual

Marco

Marco FRIIA C User manual

Marco MIX UC3 User manual

Marco

Marco MIX UC3 User manual

Marco MIX UC3 User manual

Marco

Marco MIX UC3 User manual

Popular Water System manuals by other brands

Advanced Solar Technologies Sunshine Solar owner's manual

Advanced Solar Technologies

Advanced Solar Technologies Sunshine Solar owner's manual

Royal Prestige FrescaPure 3000 Plus Use & care manual

Royal Prestige

Royal Prestige FrescaPure 3000 Plus Use & care manual

Wrekin Water QC100 quick start guide

Wrekin Water

Wrekin Water QC100 quick start guide

Kärcher BPE 4000/45 instructions

Kärcher

Kärcher BPE 4000/45 instructions

EcoWater ES9120R owner's manual

EcoWater

EcoWater ES9120R owner's manual

CEFLA PURE 500 operating manual

CEFLA

CEFLA PURE 500 operating manual

Julabo Corio C Original operating manual

Julabo

Julabo Corio C Original operating manual

clage Zip HydroTap G4 C 175 operating instructions

clage

clage Zip HydroTap G4 C 175 operating instructions

Idex MICROPUMP 668-400-2 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

Idex

Idex MICROPUMP 668-400-2 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

Global Industrial 761219 user manual

Global Industrial

Global Industrial 761219 user manual

Kingspan FPW18 installation manual

Kingspan

Kingspan FPW18 installation manual

Everpure Dual Series Housing CGS-12 10 Specification sheet

Everpure

Everpure Dual Series Housing CGS-12 10 Specification sheet

Cooke WATER WITCH SMART SENSE Product support guide

Cooke

Cooke WATER WITCH SMART SENSE Product support guide

Alternative Energy Company Energie ECO 200esm owner's manual

Alternative Energy Company

Alternative Energy Company Energie ECO 200esm owner's manual

Ecoflo ESE50WB1830 owner's manual

Ecoflo

Ecoflo ESE50WB1830 owner's manual

Aquapure AP Installation and operating instructions

Aquapure

Aquapure AP Installation and operating instructions

BIO-MICROBICS SeptiTech STAAR 1.2 Operation and maintenance manual

BIO-MICROBICS

BIO-MICROBICS SeptiTech STAAR 1.2 Operation and maintenance manual

BIO-MICROBICS MicroFAST 0.5 Service manual

BIO-MICROBICS

BIO-MICROBICS MicroFAST 0.5 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.