CONTENTS Page
BASIC PRODUCT INFORMATION . . . . . . . . . . . 9
PRECAUTIONS FOR USE . . . . . . . . . . . . . . . . 10
TIPS ON TAKING YOUR BLOOD PRESSURE ..10
INSTALLING BATTERIES AND SETTING THE
CLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
CORRECT MEASURING POSTURE . . . . . . . . . 12
Page
WRAPPING THE CUFF . . . . . . . . . . . . . . . . . . 12
MEASUREMENT PROCEDURES . . . . . . . . . . . 13
MEMORY FUNCTIONS . . . . . . . . . . . . . . . . . . 13
DELETING STORED DATA . . . . . . . . . . . . . . . . 14
CARE AND MAINTENANCE . . . . . . . . . . . . . . 14
ERROR DISPLAYS AND TROUBLESHOOTING .. 15
MARK OF FITNESS FIVE YEAR WARRANTY
-U.S. Customers Only-
Mark of Fitness, Inc., warrants this product to be free of defects in material and workmanship for a period of five years,
except cuff which has one year warranty.
Should any defects be discovered within five years of purchase,Mark of Fitness,Inc.will repair the defective product or parts
at no charge for labor or materials provided:
Said unit is returned postage paid to the factory for servicing,marked Attn:Service Department.
Proof of date of purchase is included with the product.
A letter accompanies the product and indicates the complaint or defect to be remedied.
A check or money order in the amount of $7.95 is included to cover the shipping and handling costs.
In the event the defect may be remedied without returning the unit, contact the firm by phone or mail first, and every effort
will be made to supply the replacement parts quickly and at no charge.
This warranty does not apply to any unit that has been tampered with, abused,accidentally damaged or to damage incurred
through improper packing and mishandling in transit to or from the factory.
This warranty gives you specific legal rights,and you may have other rights which vary from state to state.
e-mail [email protected]
web site www.markoffitness.com
Mark of Fitness, Inc.
621 Shrewsbury Avenue
Shrewsbury,New Jersey 07702
Phone (732) 842-7200 Fax (732) 842-0558
Customer Service (888) 343-1558
1.
2.
3.
4.

2
1
34
5 6
8 9
7
10 12
11
YEAR
ANNEE
AÑO
ANO
MONTH
MOIS
MES
MÊS
HOUR
HEURE
HORAS
HORA
DAY
JOUR
DIA
DIA
1-1 1-2 2
PARTS NAMES AND PRODUCT COMPONENTS
DISPLAY (SYS:systolic/DIA:diastolic/PUL:pulse) ON/OFF BUTTON MEMORY BUTTON M1 MEMORY BUTTON M2
AIR CONNECTOR ACADAPTER JACK CUFF HOLDER CUFF CUFF RING
AIR HOSE TUBE PLUG CARRYING BAG 4 X AA BATTERY INSTRUCTION MANUAL
NOM DES PIÈCES ET COMPOSANTES DU PRODUIT
NOMBRE DE LAS PIEZAS Y COMPONENTES DEL PRODUCTO
NOMES DAS PEÇAS E COMPONENTES DO PRODUTO
1
5
10
6
11
7
12 13 14
8 9
2 3 4
fig.1
INSTALLING BATTERIES AND SETTING THE CLOCK
p.11
14
3
4
2
5
6
8
9
7
10
13
12
11
1
- 2 - - 3 -

dfhfgjtkdfghhg!
..............
sfhdfrejrgyk;
1 inch
1
1 2
3
2
3
4
13 14
MINUTE
MINUTE
MINUTOS
MINUTO
fig.4
MEASUREMENT PROCEDURES
p.13
MÉTHODE DE MESURE
p.X
CÓMO EFECTUAR LA MEDICIÓN
p.X
PROCEDIMENTOS DE MEDIÇÃO
p.X
SYS
mmHg
DIA
mmHg PUL
/min MEMORY BANK NUMBER
NUMÉRO INUTILISÉ DE LA
MÉMOIRE
NÚMERO DE BANCO DE MEMORIA
NÚMERO DO BANCO DE MEMÓRIA
fig.2
CORRECT MEASURING POSTURE
p.12
POSTURE DE MESURE
p.X
POSTURA CORRECTA DE MEDICIÓN
p.X
POSTURA CORRECTA PARA MEDIÇÃO
p.X
fig.3
WRAPPING THE CUFF
p.12
ENROULEMENT DU BRASSARD
p.X
COLOCACIÓN DEL BRAZALETE
p.X
COLOCAÇÃO DA BANDA
p.X
5
11
- 4 - - 5 -

1 1
2
3
2
1
2
HEURE
HORA
TEMPO
DATE
FECHA
DATA
30 30
4
Average number of total
stored data
moyenne
Media
médio
fig.5
MEMORY FUNCTIONS
p.13
FONCTIONNEMENT DE LA MÉMOIRE
p.X
FUNCIONES DE MEMORIA
p.X
FUNÇÕES DA MEMÓRIA
p.X
fig.6
DELETING STORED DATA
p.14
latest data
latest data
Derni
Derni
ères donn
es donn
ées
es
medici
medici
ón m
n m
ás r
s r
eciente
eciente
Últimos dados
ltimos dados
latest data
Dernières données
medición más reciente
Últimos dados
MEMOR
MEMOR
Y D
Y D
ATA NUMBER
A NUMBER
NO
NO
.DES DONN
DES DONN
ÉES DE LA
ES DE LA
MÉMOIRE
MOIRE
NÚMERO DE REGISTRO DE
MERO DE REGISTRO DE
MEMORIA
MEMORIA
NUMERO DO RESUL
NUMERO DO RESUL
TADO
ADO
MEMORY DATA NUMBER
NO. DES DONNÉES DE LA MÉMOIRE
NÚMERO DE REGISTRO DE MEMORIA
NUMERO DO RESULTADO
SYS
mmHg
DIA
mmHg
PUL
/min
2nd latest data
Avant-dernières données
2º medición más reciente
Penúltimos dados
Oldest data
Données les plus anciennes
Dato más antiguo
Dados mais antigos
- 6 - - 7 -

BASIC PRODUCT INFORMATION
This manual is intended to assist the user in the safe and efficient operation
of the Model MF-46 Digital Blood Pressure Monitor.The product must be
used in accordance with the procedures contained in this manual and
must not be used for purposes other than those described herein. It is
important to read and understand the entire manual. In particular, please
read carefully and become familiar with the section entitled “TIPS ON
TAKING YOUR BLOOD PRESSURE”.
The user is cautioned that the system may fail to yield specified measurement
accuracy if operated or stored in temperature or humidity conditions outside
the limits stated in the specifications section of this manual. Also, an
inaccurate reading may result if this instrument is used on a child's arm.
Consult your physician if you wish to take a child's blood pressure.
Indications for Use
The MF-46 system is intended for the non-invasive measurement of systolic
and diastolic blood pressure and determination of heart rate in adult patients,
i.e., age 15 and above.The product is recommended for use by patients
with labile blood pressure or known hypertension in a home care environment
as an adjunct to medical management. The cuff will accommodate an
upper arm circumference range of approximately 8.7 to 12.6 inches (22
to 32 centimeters). Pressure is measured over a range of 0 to 300 mmHg
and heart rate over a range of 40 to 160 beats/minute.
Method of Measurement
This product employs the oscillometric method for measurement of blood
pressure and heart rate.The cuff is connected to the main unit and wrapped
around the arm. Circuits within the monitor sense the small oscillations in
pressure against the cuff produced by the expansion and contraction of the
arteries in the arm in response to each heart beat.The amplitude of each
pressure wave is measured, converted to millimeters of mercury, and
displayed on the LCD as a digital value. Memory circuit stores the 30
most recent measurement results for comparison.
Accuracy was evaluated during clinical studies in which results with the MF-
46 system were compared with simultaneous auscultatory measurements
obtained with a standard sphygmomanometer. In these studies, the onset
of the fourth (or fifth) Korotkoff sound was taken as the diastolic pressure
for the purpose of determining overall efficacy. A copy of this study is available
from the manufacturer on request.To insure that accuracy is maintained,
compare readings obtained with the MF-46 system with values measured
by a trained observer using a manual sphygmomanometer at least every
6 months.
Blood pressure measurements determined with this device are equivalent
to those obtained by a trained observer using the cuff stethoscope
auscultation method, within the limits prescribed by theAmerican National
Standard, Electronic orAutomated Sphygmomanometers.
The MF-46 system has the ability to function according to its specifications
in the presence of common arrhythmias such as atrial or ventricular
premature beats or atrial fibrillation.
CAUTION!
Do not use cuffs other than the original cuff
included with this product.
Model : MF-46
Operating Principle : Oscillometric method
Indicator : 13 digits LCD display
Pressure indicating Range : 0 to 300 mmHg (Cuff pressure)
Measuring Range : 50 to 250 mmHg (systolic)
40 to 180 mmHg (diastolic)
40 to 160 pulse/min. (pulse rate)
Accuracy : ±3 mmHg (Cuff pressure)
±5% of reading (pulse rate)
Inflation : Automatic inflation
Deflation : Electric control valve
Exhaust : Automatic exhaust valve
Power Supply :4 pcs. 1.5 volt "AA" (R6P/LR6) type batteries
or AC adapter
Power Consumption :4W (max.)
Memory :30 measurement results x 2, computation
of the average of stored Data
Operating environment :+50˚F to+104˚F, 15 to 90% relative humidity
Storage environment :-4˚F to+122˚F, 15 to 95% relative humidity
Cuff :Coverage arm circumference ; 8.7 to 12.6 in.
[22 to 32 cm]
Main Unit : Weight ;Approx.13.4 oz.[370 g] (without
batteries)
Size ; 6.4 x 7 x 3.2 in [163 x 180 x 83 mm]
(W x D x H) when CUFF HOLDER attached
Specifications are subject to change without notice due to improvements
in performance.
SPECIFICATIONS
- 9 -
Table of contents