MarMonix MAL-250 User manual

MAL-250
User’s Manual
Promote your assessment
www.marmonix.co
All rights reserved for MARMONIX Corporation Ltd.
Product Datasheet
Product descripon
1.Vane Impeller
2.Temperature & Humidity Sensors
3.LCD with White Backlight
4.Unit Buon
5.Power Buon
6.Set Buon
7.Baery Cover
8.Lanyard Aachment Point
How to operate:
3. Units Switch Funcon
In any measurement mode quickly press the Units Buon to change
the measurement units displayed. i.e. oC or oF units display.
4. Hold Funcon
Press the Units Buon over 2 seconds to freeze current readings dis-
played.
Press this buon over 2 seconds again to exit this mode.
**NOTE: In Altude Mode press Units Buon for over 2 seconds
switch to Relave Altude Mode (See Mode 8). There is not hold
funcon in the Altude Mode**
5. Switching Operang Modes
Press Set buon to change the required mode.
6. Backlight funcon
Press Set buon over 2 seconds to turn on/o the backlight.
7. Beaufort scale
The Beaufort scale is always displayed according to current wind
speed in all modes
How to operate:
Operang mode introducon
1. Turning On and O your Meter
a. Press the Power Buon for over 2 seconds to turn on
your meter. Aer 10 minutes without any operaon the
meter will power o.
b. To override the Auto Power O hold down the Set
Buon then press the Power Buon to turn on. You will
see the Power Symbol appear on the LCD. Warning, the
meter will stay on unl the baery runs out unless you turn
o by holding down the Power Buon.
2. Max/Min/Avg Value Measurement Funcon
In any measurement mode quickly press the Power Buon
to choose Maximum Reading, a second press will display
the Minimum Reading, a third press will display the Average
reading and a forth press will return the meter to the stand-
ard current readings.
Max: When is this mode the meter will display the maxi-
mum value reached
Min: When is this mode the meter will display the mini-
mum value reached
AVG: When is this mode the meter will display the average
value reached
*Once the meter is switched on it will start to record the
Max/Min/Avg values*
Press SET Buon to change the display modes:
Wind Speed -> Wind Chill ->Temperature ->Relave Humidity -> Heat
Index -> Dew Point -> Barometric Pressure -> Pressure Altude
Mode 1: Wind speed
1. Wind Speed Units: m/s, /min, knots, km/h, mph
2. Max/Min/Avg Wind Speed Reading Display
3. Hold Current Wind Speed Reading
4. Beaufort Scale
5. Wind Speed Readout
Mode 2: Wind chill
Wind chill means the eect that air temperature combined with wind
speed has on human skin or an object.
1. Wind Chill Units: oC or oF
2. Max/Min/Avg wind chill reading display
3. Hold Current Wind Chill Reading
4. Beaufort Scale
5. Wind Chill Readout

User’s Manual
Promote your assessment
www.marmonix.co
All rights reserved for MARMONIX Corporation Ltd.
Product Datasheet
Mode 3: Temperature
1. Temperature Units: oC or oF
2. Max/Min/Avg Temperature Reading Display
3. Hold Current Temperature Reading
4. Beaufort Scale
5. Temperature Readout
Mode 4: Relave Humidity
1. Relave Humidity Units: %RH
2. Max/Min/Avg Relave Humidity Reading Display
3. Hold Current Relave Humidity Reading
4. Beaufort Scale
5. Relave Humidity Readout
Mode 5: Heat index
The heat index also known as apparent temperature is what
the temperature feels like to the human body when relave
humidity is compared with air temperature. The heat index
is higher than the normal air temperature unless out of
range.
1. Heat Index Units: oC or oF
2. Max/Min/Avg Heat Index Reading Display
3. Hold Current Heat Index Reading
4. Beaufort Scale
5. Heat Index Readout
Mode 6: Dew point temperature
Dew point temperature means the temperature at which air becomes
saturated with moisture.
1. Dew Point Temperature Units: oC or oF
2. Max/Min/Avg Dew Point Temperature Reading Display
3. Hold Current Dew Point Temperature Reading
4. Beaufort Scale
5. Dew Point Temperature Readout
Mode 7: Barometric pressure
1. Barometric Pressure Units: hpa, mbar, inHg
2. Max/Min/Avg Barometric Pressure Reading Display
3. Hold Current Barometric Pressure Reading
4. Beaufort Scale
5. Barometric Pressure Readout
Mode 8: Pressure Altude (Absolute/Density & Rela-
ve Altude)
1. Altude Units: m, (Meters or Feet)
2. Max/Min/Avg Altude Reading Display
3. Hold Current Altude Reading
4. Beaufort Scale
5. Altude Readout

User’s Manual
Promote your assessment
www.marmonix.co
All rights reserved for MARMONIX Corporation Ltd.
Product Datasheet
Trouble Shoong
1. The Meter is displaying the wrong readings
Enter the calibraon mode and correct using a known trusted source
such as a reputable internet source for Barometric and Altude
Readings. Or a known accurate stable air ow will need passing
through the meter vane in working mode (an accredited wind ow
tunnel is strongly recommended), to assist in calibrang the wind
speed.
2. Power on but no display or the display disappears
a. Check the baery is in place with good contact to the pins and
the correct way up.
b. Remove baery for one minute and re-install.
c. Replace the baery.
3. For all other issues please contact your supplier.
Relave Altude Measurement
To view the relave altude, or the change in altude since
last calibraon (referred to as climb or ascent / descent),
press and hold the Units Buon for two seconds, the LCD
will then display the REL interface on screen and then rela-
ve altude (Defaulted value 0m). The value on the screen
will change as the Anemometer is moved higher or lower
than its current posion. Press and hold the Units Buon
again for two seconds to change back to Absolute (Density)
Altude. Please see below picture:
Baery Replacement
If the meter does not power on as usual or the low baery
icon appears on the LCD display, please replace the
baeries with a new 9V baery as soon as possible.
Dispose of the baery in an environmentally safe at a recy-
cling point.
DO NOT DISPOSE IN YOUR DUST BIN!
Calibraon funcon
Step 1.Hold Units Buon then turn on meter to enter cali-
braon mode.
Step 2: Press Units buon choose the mode “see table
below”, then press Power Buon to enter the calibraon
mode;
Step 3: Press Units Buon to choose the unit you wish to
change (the selected unit will ash quickly) and press Set
Buon to adjust to the correct value,
Step 4: Press Power Buon for over 2 seconds to store the
seng and exit.
Number Calibraon Funcon Mode
1Wind Speed
2Temperature
3Relave Humidity
4Barometric Pressure
5Absolute (Density) Altude
Cauon:
1. This meter is accurate at low and mid-range air speeds. Consistent
use at very high speeds, i.e. from the window of a fast moving car
will damage the impeller’s bearing and reduce accuracy.
2. This meter is not a personal safety device.
Warranty
This meter has a one year warranty for a period of one year from
purchase date.
This warranty covers normal operaon and does not cover baeries
(including leaks), misuse, abuse, alteraon, tampering, neglect, im-
proper maintenance or improper calibraon. Nor can the warranty be
used as an excuse for a false claim simply because you have changed
your mind aer the inial 14 day period.
Proof of purchase is required for warranty repairs.
Other MarMonix Measuring Instrument manuals