Marquis Spas LEISURE SERIES User manual

LEISURE SERIES
SPORT SERIES
COASTAL SERIES
ULTIMATE SERIES
Owner’s Manual

WELCOME TO THE SPA LIFE!
Please enjoy your new Marquis spa, but think Safety First. Read your Owner s Manual
in its entirety before installing your spa and encourage all spa users to do the same.
More than just common sense, this Owner s Manual provides vital safety and operational
information.
Every effort has been made to ensure the accuracy of this manual. However, Marquis
Spas reserves the right to improve its product without notice. This could create a minor
variation between this manual and the actual product you receive. We apologize for any
inconvenience this may cause.
SERIAL NUMBER LOCATION
On your spa, the serial number is engraved directly above the filter canister area. On
models listed by Underwriters Laboratories, you will also find the serial number on the
tag in the equipment area.
PLEASE FILL OUT AND KEEP FOR FUTURE REFERENCE
__________________________________________________________________________
Name of Purchaser Date of Purchase
__________________________________________________________________________
Address
_________________________________________________________________________
City State Zip Code
__________________________________________________________________________
Signature Telephone
_________________________________________________________________________
Spa Model / Series / Color Spa Serial # Pack Serial #
__________________________________________________________________________
Retailer s Name
_________________________________________________________________________
Retailer s Address Telephone
__________________________________________________________________________
City State Zip Code
We sincerely hope your spa life is a pleasant experience. If problems should arise, contact
your Marquis retailer. Or contact Marquis Corp. by using one of the methods below.
596 Hoffman Road, Independence, OR 97351
Voice: (503)838.0888 (800)275.0888
e-mail: [email protected] www.marquisspas.com
Copyright Marquis Corp. 1/2001 710-0812
OWNER’S MANUAL
MARQUIS SPAS • RELAXING YOUR WORLD
marquis spas®

IMPORTANT SAFETY INSTRUCTIONS
120V, 240V, All Spa Models, Personal Safety..................................................................................3-6
SPA INSTALLATION
Location.................................................................................................................................................................7-8
Ozonator Installation......................................................................................................................................8-9
Electrical Requirements................................................................................................................................9-10
STARTING YOUR SPA............................................................................................................................. 10-11
OPERATING YOUR SPA
Priming the Pump............................................................................................................................................12
Hydrotherapy Jets............................................................................................................................................13
SPA SPECIFICATIONS ALL MODELS.................................................................................14
LEISURE SERIES MODELS & EQUIPMENT DIAGRAMS
Oasis....................................................................................................................................................................... 15
Spirit........................................................................................................................................................................ 16
Spirit LX................................................................................................................................................................ 17
Mirage.................................................................................................................................................................... 18
Mirage LX.............................................................................................................................................................19
LS Controls..........................................................................................................................................................20-22
Zoned Jetting Operation..............................................................................................................................22-24
SPORT SERIES MODELS & EQUIPMENT DIAGRAMS
500...........................................................................................................................................................................25
500 LX...................................................................................................................................................................26
600...........................................................................................................................................................................27
600 LX...................................................................................................................................................................28
700...........................................................................................................................................................................29
700 LX...................................................................................................................................................................30
SS Controls......................................................................................................................................................... 31-33
Zoned Jetting Operation.............................................................................................................................34-38
COASTAL SERIES MODELS & EQUIPMENT DIAGRAMS
Destiny...................................................................................................................................................................39
Reward.................................................................................................................................................................. 40
Euphoria................................................................................................................................................................41
Voyage....................................................................................................................................................................42
CS Controls........................................................................................................................................................ 43-46
Zoned Jetting Operation.............................................................................................................................47-50
ULTIMATE SERIES MODELS & EQUIPMENT DIAGRAMS
Marquis..................................................................................................................................................................51
Journey.................................................................................................................................................................. 52
US Controls........................................................................................................................................................53-55
Zoned Jetting Operation.............................................................................................................................56-59
SPA MAINTENANCE
Cleaning the Spa Interior and Exterior.................................................................................................60
Draining and Refilling the Spa....................................................................................................................60-61
Winterizing the Spa........................................................................................................................................62
Spa Maintenance Schedule & Record..................................................................................................63-64
TROUBLESHOOTING
Equipment and LCD Display Messages...............................................................................................65-66
Spa Water............................................................................................................................................................67-68
OWNER’S MANUAL INDEX
MARQUIS SPAS • RELAXING YOUR WORLD 2

SAFETY INSTRUCTIONS
MARQUIS SPAS • RELAXING YOUR WORLD 3
The following instructions are required to be printed by Underwriters Laboratories (UL) as
a condition of the listing of this product. They contain important safety information, and
we strongly encourage you to read and apply them.
IMPORTANT SAFETY
INSTRUCTIONS
WHEN INSTALLING AND USING THIS ELECTRICAL EQUIPMENT,
BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
1. READ AND FOLLOW ALL
INSTRUCTIONS
2. WARNING: To reduce the risk of injury, do not permit children to use this product
unless closely supervised at all times.
3. DANGER: RISK OF CHILD DROWNING. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure that children
cannot use the spa or hot tub unless they are supervised at all times.
120 VOLT, CORD AND PLUG CONNECTED MODELS
4. DANGER: RISK OF INJURY. Connect only to a grounded source.
5. Do not bury the power cord.
6. WARNING: To reduce the risk of electric shock, replace a damaged cord immediately.
7. A ground terminal (pressure wire connector) is provided on the surface of the control
box inside the equipment compartment. This connector should be bonded with a
minimum No. 8 AWG (8.4mm2) solid copper wire between this unit and any metal
ladders, metal water pipes, metal enclosures of electrical equipment, conduit or metal
equipment within five feet (1.5m) of the spa. If the spa is located on a reinforced
concrete pad, the reinforced steel should also be bonded to the ground terminal.
8. WARNING: Your spa is equipped with a ground fault circuit interrupter (GFCI) on
the end of the power supply cord. Before each use of the spa, with the plug
connected to the power supply and the unit operating, press the test button. The
unit should stop operating and the GFCI power indicator will go out. Wait thirty
seconds and then reset the GFCI by pressing the Reset button. The GFCI power
indicator will turn on, restoring power to the spa. If the interrupter does not perform
in this manner, it is an indication of an electrical malfunction and the possibility of an
electric shock. Disconnect the plug from the receptacle until the fault has been
identified and corrected.
NOTE: Failure to wait thirty seconds before resetting the GFCI may cause the spas
power indicator on the control panel to blink. If this occurs, repeat the GFCI test procedure.
2 0 VOLT, PERMANENTLY INSTALLED OR CONVERTED MODELS
9. A ground terminal is provided on the terminal block (TB-1, terminal 7) located inside
the control box. To reduce the risk of electric shock, connect this terminal to the
grounding terminal of your electrical service or supply panel with a continuous green,
insulated copper wire. The wire must be equivalent in size to the circuit conductors
supplying the equipment. In addition, a bonding terminal (pressure wire connector) is
provided on the outside of the control box for bonding to local ground points. To
reduce the risk of electric shock, this connector should be bonded with a No. 8 AWG
(8.42mm2) solid copper wire to any metal ladders, water pipes, or other metal within
five feet (1.5m) of the spa to comply with local requirements.
(CONTINUED)

MARQUIS SPAS • RELAXING YOUR WORLD 4
10. Your spa uses ground fault circuit interrupters in the electrical sub-panel. Before
each use of the spa and with the unit operating press the Test button on each
breaker. The switch should click over to the Trip position. Wait thirty seconds
and reset each GFCI breaker by switching it completely off and then completely on.
The switch should then stay on. If either of the interrupters does not perform in
this manner, it is an indication of an electrical malfunction and the possibility of an
electric shock. Disconnect the power until the fault has been identified and corrected.
NOTE: Failure to wait 30 seconds before resetting the GFCI may cause the spa s
Power Indicator (on the control panel) to blink. If this occurs, repeat the GFCI test
procedure.
ALL SPA MODELS
11. Install the spa so proper drainage is provided for the compartment containing the
electrical components.
12. DANGER: RISK OF ELECTRIC SHOCK. Install the spa at least five feet (1.5m) of
metal surfaces if, in accordance with the National Electric Code ANS/NMFPA70 -
1993, each metal surface is permanently connected to a minimum No. 8 (8.42mm2)
solid copper conductor attached to the wire bonding connector on the terminal box
that is provided for this purpose.)
13. DANGER: RISK OF ELECTRIC SHOCK. Do not permit any appliance, such as a
light, telephone, radio, or television within five feet (1.5m) of the spa or hot tub.
14. WARNING: To reduce the risk of injury:
The water in the spa should never exceed 104° F (40° C). Water temperatures
between 100° F (38° C) and 104° F (40° C) are considered safe for a healthy adult.
Lower water temperatures are recommended for extended use (exceeding 10
minutes) and for young children.
Since excessive water temperatures have a high potential for causing fetal damage
during the early months of pregnancy, pregnant or possibly pregnant women should
limit spa water temperatures to 100° F (38° C).
Before entering a spa, the user should measure the water temperature with an
accurate thermometer since the tolerance of temperature-regulating devices may
vary as much as +/- 5° F (3° C).
The use of drugs, alcohol, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
Persons suffering from obesity or with a medical history of heart disease, low or
high blood pressure, circulatory system problems or diabetes should consult a
physician before using the spa.
Persons using medications should consult a physician before using a spa since some
medication may induce drowsiness while other medication may affect heart rate,
blood pressure, and circulation.
15. DANGER: TO REDUCE THE RISK OF INJURY TO PERSONS. Do not remove
the suction fittings.
16. DANGER: RISK OF INJURY: Never operate a spa if the suction fitting(s) are
broken or missing. Never replace a suction fitting with one rated less than the flow
rate marked on the original suction fitting. The suction fittings in the spa are sized to
match the specific water flow created by the pump. Should the need arise to
replace the suction fittings or the pump, be sure that the flow rates are compatible.
17. DANGER: Children are especially sensitive to hot water. At no time should children
have unsupervised access to the spa. Children must not be allowed to climb onto the
spa cover. All Marquis Spas are equipped with a locking cover that meets the ASTM
F1346-91 Standard for Safety Covers. Always lock the child resistant locks after using
the spa for your children’s safety.
18. SAVE THESE INSTRUCTIONS.
(CONTINUED)
SAFETY INSTRUCTIONS

WARNING: Children should not use spas or hot tubs without adult supervision.
WARNING: Do not use spas or hot tubs unless all suction guards are installed to
prevent body and hair entrapment.
WARNING: Do not use drugs or alcohol before or during the use of a spa or hot tub
to avoid unconsciousness and possible drowning.
WARNING: People using medications and/or having an adverse medical history
should consult a physician before using a spa.
WARNING: The use of alcohol, drugs, and medication can greatly increase the risk of
fatal hyperthermia.
WARNING: Before entering the spa or hot tub measure the water temperature with
an accurate thermometer.
WARNING: Water temperature in excess of 38°C may be injurious to your health.
WARNING: Prolonged immersion in a spa or hot tub may be injurious to your health.
WARNING: People with infectious diseases should not use a spa.
WARNING: Pregnant or possibly pregnant women should consult a physician before
using a spa or hot tub.
WARNING: To avoid injury, exercise care when entering and exiting the spa or hot tub.
WARNING: Do not use a spa or hot tub immediately following strenuous exercise.
CAUTION: Maintain water chemistry in accordance with manufacturer’s instructions.
The following information is included for French speaking spa owners.
AVERTISSEMENT: Ne pas placer d’appareil électrique (luminaire, téléphone, radio,
téléviseur, etc.) moins de 1.52 m de cette cuve de relaxation.
AVERTISSEMENT: Ne pas laisser les enfants utiliser une cuve de relaxation sans
surveillance.
AVERTISSEMENT: Pour éviter que les cheveux ou une partie du corps puissent
être aspirés, ne pas utiliser une cuve de relaxation si les grilles de prise d’aspiration ne
sont pas toutes en place.
AVERTISSEMENT: Pour éviter l’évanouissement et la noyade éventuelle, ne prendre
ni drogue ni alcool avant d’utiliser une cuve de relaxation ni quand on s’y trouve.
AVERTISSEMENT: Les personnes qui prennent des médicaments ou ont des
problemès de santé devraient consulter un médecin avant d’utiliser une cuve de
relaxation.
AVERTISSEMENT: La consommation d/alcool ou de drogue augmente
considérablement les risques d’hyperthermie motrelle dans une cuve de relaxation.
AVERTISSEMEN : Avant d’utiliser une cuve de relaxation mesurer la température
de l’eau l’aide d’un thermométre précis.
AVERTISSEMENT:: Il peut être dangereux pour la santé de se plonger dans de l’eau
plus de 38°c.
AVERTISSEMENT:: L’utilisation prolongée d’une cuve de relaxation peut être
dangereuse pour la santé.
AVERTISSEMENT: Les personnes atteintes de maladies infectieuses ne devraient
pas utiliser une cuve de relaxation
AVERTISSEMENT: Les femmes enceintes, que leur grossesse soit confirmée ou non,
devraient consulter un médecin avant d’utiliser une cuve de relaxation.
AVERTISSEMENT: Pour éviter des blessures, user de prudence en entrant dans une
cuve de relaxation et en sortant.
AVERTISSEMENT: Ne pas utiliser une cuve de relaxation immédiatement aprés un
exercice fatigant.
ATTENTION:: La tenteur de l’eau en matières dissoutes doit être conforme aux
directives du fabricant.
SAFETY INSTRUCTIONS
MARQUIS SPAS • RELAXING YOUR WORLD 5
T
:
:
:
:
:
:
.
RISK OF ELECTRIC SHOCK. Do not permit any appliance, such as a
light, telephone, radio, or television within five feet (1.5m) of the spa or hot tub.
WARNING:

SAFETY SIGN
Each Marquis Spa is shipped with a SAFETY SIGN in the spa s Owner s Package. Under-
writers Laboratories (UL) recommends this sign be permanently installed where it is visible
to the users of the spa. To obtain additional Safety Signs, contact your Marquis Spas dealer
and request Part #710-0789. Replacement Owner s Manuals are also available.
PERSONAL SAFETY
Prolonged immersion in hot water can result in HYPERTHERMIA, a dangerous condition
which occurs when the internal temperature of the body reaches a level above normal
(98.6° F). The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy,
and a body temperature above 98.6° F. The physical effects of hyperthermia include
unawareness of impending hazard, failure to perceive heat, failure to recognize the need
to exit the spa, physical inability to exit the spa, fetal damage in pregnant women, and
unconsciousness resulting in a danger of drowning.
WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of
fatal hyperthermia in hot tubs and spas.
Persons taking medications which induce drowsiness such as tranquilizers, antihistamines or
anticoagulants should not use the spa. Pregnant women and persons with a medical history of
heart disease, diabetes, or high blood pressure should consult a physician before using the spa.
GENERAL INFORMATION
MARQUIS SPAS • RELAXING YOUR WORLD 6
PERSONAL SAFETY DOS:
Be sure your spa is connected to the
power supply correctly use a
licensed contractor.
Disconnect the spa from the power
supply before draining the spa or
servicing the electrical components.
Test the GFC monthly.
Test the water temperature with your
hand before entering the spa to be sure
that its a comfortable temperature.
Remember that wet surfaces can be
very slippery. Take care when enter-
ing and exiting the spa.
Use the safety cover when the spa is
not in use, whether it is empty or full
of water.
Keep the water clean and sanitized
with correct chemical care.
Turn on the jets when adding ANY
spa water chemicals into the filtration
compartment.
Clean the filter cartridge(s) monthly
to remove debris and mineral buildup
which may affect the performance of
the hydrotherapy jets, limit the flow,
or trip the high limit thermostat
which will turn off the entire spa.
PERSONAL SAFETY DONTS:
Dont use the spa with the equipment
compartment door removed.
Dont use the spa for long periods of
time at water temperatures in excess
of 104° F.
Dont allow the jet pump(s) to
operate for an extended period of
time with the cover in place.
Extended pump operation will cause
a slow heat buildup due to water
friction. The spa equipment controls
are equipped with a built-in safety
timer that will automatically shut off
the jet pump(s) after 15 minutes of
continuous operation should it have
been left on inadvertently.
Dont operate the spa at any time
with the filter cartridges removed.
Dont lift or drag the cover by using
the tie-down straps; always lift and
carry by using the handles.
Dont store chemicals in the spas
equipment compartment.
Dont hesitate to call your Marquis
Spas representative with any
questions or maintenance concerns.

MARQUIS SPAS • RELAXING YOUR WORLD 7
INSTALLATION INSTRUCTIONS
LOCATION
For your portable spa to function properly and safely, it must be located on a hard, flat,
level surface. In-ground spas require special installation techniques and should be
planned in conjunction with your spa dealer. Improper installation can result in structural
damage to the spa and the voiding of your spa warranty. Items to discuss with your
dealer include: Local construction codes, electrical service requirements, serviceability
of equipment, present underground obstructions such as gas, water and telephone lines,
safety measures such as fences, locks and visibility of the spa installation from the home,
street and neighbors.
You must allow for sufficient water drainage around the spa to help preserve the
equipment and support structure.
Your spa MUST be installed to permit access for servicing the equipment above and/or
below any decks or floors. Access is essential and must allow adequate room for
service.
Be sure the spa is in the final position BEFORE filling with water. Check for power
cords, tools, and hoses that may be caught underneath the spa.
CAUTION: Never try to move a spa that has not been fully drained. To do so could
result in damage to the spa and physical injury to the mover.
IMPORTANT: DO NOT LET AN EMPTY SPA REMAIN EXPOSED TO DIRECT
SUNLIGHT FOR MORE THAN A FEW MINUTES. Spa surface temperatures can reach
in excess of 150° F (65°C) if left exposed to the sun. Significant damage can occur if this
is allowed to happen, including warping and blistering of the surface. Damage, which
may occur as a result of this exposure, is not covered under the warranty. All warranties
have exclusions to this type of damage.
SHUT-OFF VALVES
Your spa is equipped with shut-off valves (see equip-
ment diagram on spa model page) that shut off the
water flow to the equipment system for dealer service.
At times, a new spa or one that has recently been
serviced, may have the shut-off valves partially closed
which can restrict the water flow and hinder jet
performance. Be sure the valves are fully open.
FREEZE PROTECTION
When a freeze condition is detected (which occurs
when the temperature in the heater housing drops to 40° F) the jet pump(s) is
automatically activated.
In areas with extreme cold winter conditions, your spa should be fine as long as it is left
running at normal operating temperatures. If you plan to turn the spa off, you must
follow the instructions in this manual for winterizing your spa.
J

MARQUIS SPAS • RELAXING YOUR WORLD 8
INSTALLATION INSTRUCTIONS
OVERHEATING
In the case of extended hot weather, the spa water temperature may reach and maintain
104° F to 106° F. This is due to the ambient temperature and the full insulation in the
spa cabinet. The simplest solution to this heat buildup is, lifting the spa cover a few
inches for several hours to allow the heat to escape. You may also have the option of
shortening the pump-run time. See Control panel section for available options.
FILTER CARTRIDGE
Your portable spa is equipped with the Constant Clean Filtration system. All 2000 and
beyond Marquis Spas use #5040, 50 sq. ft. T-Handle Filter cartridge.
Oasis, Spirit, Mirage, Spirit LX, Mirage LX, 500, 600 and 700: Features Vortex
Filter that includes Hi-Flo Vortex skimmer and filament filter cartridge.
500 LX, 600 LX, 700 LX, Reward, Destiny, Euphoria,Voyage, Marquis and
Journey US: Features two Vortex Filters which include Hi-Flo Vortex skimmers and
filament filter cartridges.
NOTE: It is very important that the components of these filtration systems be installed
properly in the proper part of the spa (see jetting diagram and REMOVING THE FILTER
for complete instructions).
JSUCTION FITTINGS
There are suction fittings in the footwell of your spa.
These are openings through which the jet-pumps draw
water. They have been equipped with safety covers.
Suction through the fittings can be strong. The safety
covers must remain in place and undamaged. A fitting
with a damaged cover can be dangerous, especially to
small children or people with long hair. Should any part
of the body become drawn to a fitting, turn the jet-
pump off immediately. Long hair should be restrained
in a bathing cap, never allow it to float freely in the spa.
Replace any missing or damaged suction covering.
OZONATOR INSTALLATION ON LEISURE AND SPORT SERIES
If your Leisure or Sport Series spa was not originally equipped with an ozone generator
and you would like to install one, refer to the following instructions and those supplied
with the ozonator. NOTE: The only ozonator U.L. listed for your spa is the Marquis
Spa Ozone Generator, available at your Marquis retailer, part OZU 120.
1. Turn off the power to the spa.
2. Open the equipment area door.
3. Plug the ozonator into the ozone receptacle on the spa control box.
4. Cut a 5" piece of the supplied 1/4" tubing and using silicone sealant, push one end
onto the 1/4" barbed fitting on the ozonator.
5. Into the other end of this tube, insert the supplied check valve, being sure the
direction of flow is away from the ozonator, not toward it.
6. Cut a long piece of tubing and make a loop approximately 8-10" in diameter, then
push it onto the exposed end of the check valve.
(CONTINUED)

INSTALLATION INSTRUCTIONS
MARQUIS SPAS • RELAXING YOUR WORLD 9
7. Remove the black cap from the barbed fitting suspended above the equipment
(some water may drip from this fitting, have a towel handy).
8. Place the exposed tubing end on the 1/4" barb.
9. There is a labeled mounting block attached to the spa which shows the
mounting position of ozonator.
CAUTION: DO NOT PREDRILL SCREW HOLES.
10. Turn on the power to the spa. You will see the ozonator s blue light turn on and
bubbles come out of the single ozone jet in the spa with the primary pump on
low-speed operation.
11. Close the equipment door.
ELECTRICAL REQUIREMENTS
It is the responsibility of the spa owner to ensure that all electrical connections are made
in accordance with all electric codes in effect at the time of installation.
2 0 Volt:
All connections must be made in accordance with the wiring diagram found on the
inside of the control box cover. Connections should be made with copper conductors
only aluminum wiring should not
be used with this system. All
conductors, circuit breakers, and/or
fuses must be sized in accordance to
the Total Amperage Load as
specified:
Permanently connected
Rated 240V, 60Hz, 50A, three
wires plus ground (6 AWG
copper)
Fuse or circuitbreaker size: 50 amp
This equipment is designed to
operate on 60Hz Alternating
Current only at a voltage of 240.
Units to be operated at 240V must
have all connections made by a
qualified electrician in accordance
with any electric codes in effect at
the time of installation. All 240V
units require a three wire plus ground (line 1, line 2, neutral, ground). Refer to the
label at the terminal block.
A pressure wire connector is located on the exterior of the control box. If the
installation includes a common bonding grid (reinforced concrete slab, ground plate
beneath the spa, or any metal water pipe connection), this pressure wire connector
should be bonded, with at least #8 AWG (8.42mm2, #6 in Canada) copper wire, to
any metal ladder, water pipe, or other metal, within five feet of the spa.
(CONTINUED)

120 Volt:
120V units must only be connected to a
properly grounded, grounding type15
amp receptacle. 120V equipment is
designed to operate on 60Hz Alternat-
ing current only at a voltage of 120, 12.5
amp. maximum load.
To Convert 120V to 240V
All connections must be made by a
licensed electrician.
1. Disconnect from power and remove
cord.
2. Move red wire (TB-1) to (TB-4) as
indicated by gray area.
3. Move the Heater Mode selector
(J23) on the Control Board from
(20A) to (50A) position.
Ground Fault Circuit Interrupters
(GFCI), #8145, are available from your
Dealer.
START-UP PROCEDURE
Your spa is equipped with solid state preprogrammed Comfort Controls specific to your spa
model. Please see the CONTROLS section listed under your particular spa series model.
To start your spa, you will need a spa water test kit and an underwater thermometer. It
is important to follow each of these steps when starting your spa.
Leisure Series Models Start-up:
1. Place spa on a hard, flat, level surface. Make sure the power supply is off.
2. Make sure that the suction fittings in the footwell are
in place and undamaged.
3. Open the equipment door. Screw the pump plug
(supplied in packet) into the face of the pump.
Close the drain valve and screw the drain valve cap on
tightly. Tighten all disconnects and open all shut-off
valves. On models Equipped with AWP external
drain, close valve by turning outer ring clockwise. Be
sure the center plug is in place and tighten.
J
INSTALLATION INSTRUCTIONS
(CONTINUED)
MARQUIS SPAS • RELAXING YOUR WORLD 10
STARTING YOUR SPA

MARQUIS SPAS • RELAXING YOUR WORLD 11
STARTING YOUR SPA
START-UP PROCEDURE
4. Fill the spa with water to two-thirds of the way up the
Vortex skimmer opening(s). The use of a Fill Filter,
#5039, is recommended, especially in areas with high
mineral content in the water.
5. Turn the power on and wait five seconds.
6. At this time the spa should have water flowing from the
jets. If the pump has not primed and water is not
flowing from the jets after two minutes TURN OFF
POWER TO THE SPA and vent air from the pumps
by slightly opening the pump union. (See TROUBLE
SHOOTING, Water Flow.)
7. Your spa water temperature is preset at 100° F. Use the TEMP SET pad on the
bather s control panel to set the water temperature to the desired level.
8. SHOCK the water and test the water chemistry following the instructions in
your Marquis Spa Care Water Treatment Guide, included with the spa. (Also see
WATER CHEMISTRY GUIDELINES below.)
9. Place the cover on the spa. It will take 12 to 24 hours for the water to heat to set
temperature.
10. Check the water temperature and adjust the setting if necessary. Normal use
is between 98° and 102° F.
Sport, Coastal and Ultimate Series Models Start-up:
1. Follow steps one through three of Leisure Series Models Start-up.
2. Check to make sure the freeze line is properly connected.
3. Follow steps five through ten of Leisure Series Models Start-up.
WATER CHEMISTRY GUIDELINES
There are several methods available to sanitize the spa water. We recommend using
chlorine or bromine and ozone. No other oxidizing agents are suggested. Use of other
oxidizing agents may damage equipment and void the warranty.
Shock Sanitation:
Shock sanitize your spa water after filling it before using the spa. This treatment provides
initial sterilization as well as kills any algae spores that may be present and oxidize
undesirable minerals and organic matter in the raw water. Repeat shock treatment
anytime the spa is refilled or the water has lost its chemical control due to neglect.
We recommend the use of sodium dichloracyanurate (DyCloro) or lithium hypochlorite.
Calcium hypochlorite is used for swimming pools and is not recommended for spas. Tri-
Cloro is not recommended either.
It s important that you read and follow the safety tips for chemical usage and storage
listed in the Water Treatment Guide. (Also see RECOMMENDED CHEMICAL LEVELS
under TROUBLESHOOTING.)
J

THERAPY PUMP(S)
Allow the spa to circulate on high-speed (see instructions for spa side controls) for 4-5
minutes to discharge air from the plumbing system. Do not expect hot water immedi-
ately from the jets; the heater will take several hours to heat the water.
Pr Diagnostic Message
NOTE: Coastal and Ultimate Series spas have a pump priming feature which begins
at start-up. When the spa is energized, the LCD panel will display a Pr message. This
mode will last approximately four to five minutes if not exited manually. To exit
manually, press the TEMP SET pad. At this time
the spa should have water flowing from the jets.
If the pump has not primed and water is not
flowing from the jets after two minutes, TURN
OFF POWER TO THE SPA. Vent air from
the pumps by slightly opening the pump unions
(see TROUBLESHOOTING section, Water
Flow). After turning the power on again, the
spa will initiate a new priming mode. Repeat
steps above.
After you have manually exited the priming mode (or you allowed the spa to automati-
cally exit) the LCD display will momentarily display 100° F and then the display will
switch to - -° F. The system requires approximately one minute of water flow to deter-
mine the water temperature. After one minute of water flow, the temperature will be
displayed as actual water temperature F. Press the TEMP SET pad to adjust the desired set
temperature for the spa.
NOTE: Your spa has been filled and test-run at the factory. The first time your spa is
filled with water, some discoloration from residual test
water may appear. This will disappear when the spa is
completely filled and the filtration system is functioning.
Test the water for the proper chemical balance and adjust
as necessary. Marquis Spa Care Products are recom-
mended. PROPER CHEMICAL BALANCE IS
IMPORTANT.
SAFETY ENERGY COVER
When the spa is not in use, the safety energy cover
should be kept on the spa to retain the water s heatand
to keep out dirt, leaves, etc. Your heater will maintain a
constant water temperature between spa uses.
For your safety and convenience, the cover is
equipped with safety locks. Marquis suggests that you
use them to help keep out unintended users and
prevent covers from being blown off in windy condi-
tions. For high wind areas, Secure Straps are available.
Duralift cover lifts are also available to assist you in
cover removal. See your Marquis Dealer.
MARQUIS SPAS • RELAXING YOUR WORLD 12
J
OPERATING YOUR SPA
J

OPERATING YOUR SPA
MARQUIS SPAS • RELAXING YOUR WORLD 13
MAXIMUM THERAPY JETTING SYSTEM
JET SELECTOR VALVE
The large, gray teardrop Jet Selector lever allows you to
redirect the water flow to different jet zones. (See ZONED
JETTING for specific options.)
CASCADE NECK JETS
Your spa may be equipped with a Therapy Seat(s) featuring
especially high Cascade Neck Jets. These jets are turned on and
off (when the jet pump is on) using the small teardrop Neck Jet
Control lever.
ISO BOOST JET
Small directional jets are strategically located to complement
the larger jets. Simply moving the nozzle redirects the water for
ideal massage. The water flow can be adjusted by using the
four tabs on the face of the jet to turn it.
POWER BOOST JET
The direction of water flow can be changed by redirecting the
central nozzle. The water flow can be adjusted by using the
four tabs on the face of the jet to turn it.
POWER SWIRL JET
Large, rotating jets provide a firm, broad area of circular massage
action. The water flow can be adjusted by using the four tabs
on the face of the jet to turn it.
CYCLO BOOST JET
This large, versatile jet flows in a straight stream. The water
flow can be adjusted by using the four tabs on the face of the
jet to turn it.
CYCLO SWIRL JET
This large, versatile jet can flow straight or can be made to
rotate by pushing the nozzle to the side (push in the direction
indicated by the point of its teardrop shape). The water flow
can be adjusted by using the four tabs on the face of the jet to
turn it.
HYDRO KINETIC (HK 0) JET
Unique Jets are strategically positioned around the perimeter of
the spa to produce a true whirlpool flow of water. This action
provides a passive, whole body massage.
GEYSER/WHIRLPOOL JET
This high-flow jet is perfect for intense foot and leg massage.
INTERCHANGEABLE JETS
Many jets are interchangeable. See your Marquis Dealer for
additional jets to customize your hydrotherapy experience.
Jet Selector Valve
Iso Boost Jet
Power Boost Jet
Cyclo Swirl Jet
HK 0 Jet
Geyser/Whirlpool Jets

MARQUIS SPAS • RELAXING YOUR WORLD 14
SPA SPECIFICATIONS
Therapy
Pump(s)
1 2-speed
48 frame
1 2-speed
48 frame
1 2-speed
56 frame
1 2-speed
48 frame
1 2-speed
56 frame
1 2-spd 56 frame
1 1-spd 48 frame
1 2-spd 56 frame
1 1-spd 48 frame
1 2-spd 56 frame
1 1-spd 48 frame
1 2-spd 56 frame
1 1-spd 48 frame
1 2-spd 48 frame
1 1-spd 48 frame
1 2-spd 56 frame
1 1-spd 48 frame
2 2-speed
56 frame
2 2-speed
56 frame
2 2-speed
56 frame
2 2-speed
56 frame
3 2-speed
56 frame
3 2-speed
56 frame
Electrical
Required
120V/15 amp
240V/40 amp
120V/15 amp
240V/40 amp
240V/40 amp
120V/15 amp
240V/40 amp
240V/40 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
240V/50 amp
Spa
Dimensions
54"x84"x29"h
28" deep
60"x84"x29"h
28" deep
60"x84"x29"h
28" deep
78"x78"x31"h
30" deep
78"x78"x31"h
30" deep
78"x84"x33"h
32" deep
78"x84"x33"h
32" deep
84"x84"x35.5"h
34" deep
84"x84"x35.5"h
34" deep
84"x84"x35.5"h
34" deep
84"x84"x35.5"h
34" deep
84"x84"x35.5"h
34" deep
84"x84"x35.5"h
34" deep
90"x90"x35.5"h
34" deep
90"x90"x35.5"h
34" deep
90"x90"x35.5"h
34" deep
90"x90"x35.5"h
34" deep
Weight
Dry/Full
340/
1424 lbs.
410/
1786 lbs.
410/
1786 lbs.
475/
2226 lbs.
475/
2226 lbs.
590/
2240 lbs.
590/
2240 lbs.
660/
3162 lbs.
660/
3162 lbs.
680/
3348 lbs.
680/
3348 lbs.
690/
3192 lbs.
720/
3388 lbs.
800/
4302 lbs.
810/
4312 lbs.
850/
4352 lbs.
865/
4034
Spa Model
Series
Oasis
Leisure Series
Spirit
Leisure Series
Spirit LX
Leisure Series
Mirage
Leisure Series
Mirage LX
Leisure Series
500
Sport Series
500 LX
Sport Series
600
Sport Series
600 LX
Sport Series
700
Sport Series
700 LX
Sport Series
Destiny
Coastal Series
Reward
Coastal Series
Euphoria
Coastal Series
Voyage
Coastal Series
Journey
Ultimate Series
Marquis
Ultimate Series
Water
Capacity
130
gallons
165
gallons
165
gallons
210
gallons
210
gallons
320
gallons
320
gallons
300
gallons
300
gallons
425
gallons
425
gallons
300
gallons
320
gallons
420
gallons
425
gallons
425
gallons
380
gallons
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○

OASIS Leisure serieS
Component Identification #
1so Boost Jets5
2Power Boost Jets4
5Cyclo Swirl Jet1
6Light1
7Air Control Valve1
8Heat Sensor 1
10 Suction Fittings 2
11 Bathers Control Panel 1
12 Auxiliary Control Panel 1
14 Floor Drain1
15 Filter Canister 1
22 Ozone njector Fitting 1
MaximumTherapy System #
1Control Box & Heater 1
2Pump Unions 2
3Pump 1
4Shut Off Valves 2
5Motor Mounts
8Pump Plug1
9 120V GFC 1
MARQUIS SPAS • RELAXING YOUR WORLD 15
Physical Specifications
Dimensions 54" x 84"
Height29"
Depth28"
Seating Positions 3
Weight Dry Lbs. 340
Weight Full Lbs. 1424
Water Capacity 130 gallons
Total Therapy Jets10

SPIRIT Leisure series
MARQUIS SPAS • RELAXING YOUR WORLD 16
Component Identification #
1so Boost Jets8
2Power Boost Jets5
5Cyclo Swirl Jet1
6Light1
7Air Control Valve1
8Heat Sensor 1
10 Suction Fittings 2
11 Bathers Panel 1
12 Auxiliary Control Panel 1
14 Floor Drain1
15 Filter Canister 1
16 Jet Selector Valve1
22 Ozone njector Fitting 1
Maximum Therapy System #
1Control Box & Heater 1
2Pump Unions 2
3Pump 1
4Shut Off Valves 2
5Motor Mounts
8Pump Plug1
9 120V GFC 1
Physical Specifications
Dimensions 60" x 84"
Height29"
Depth28"
Seating Positions 4
Weight Dry Lbs. 410
Weight Full Lbs. 1786
Water Capacity 165 gallons
Total Therapy Jets14

MARQUIS SPAS • RELAXING YOUR WORLD 17
SPIRIT LX LEISURE SERIES
Component Identification #
1so Boost Jets8
2Power Boost Jets5
5Cyclo Swirl Jet1
6Light1
7Air Control Valve1
8Heat Sensor 1
10 Suction Fittings 2
11 Bathers Panel 1
12 Auxiliary Control Panel 1
13 Cascade Neck Jets3
14 Floor Drain1
15 Filter Canister 1
16 Jet Selector Valve1
18 Neck Jet Control Valve1
20 Geyser Jets3
22 Ozone njector Fitting 1
MaximumTherapy System #
1Control Box & Heater 1
2Pump Unions 2
3Pump 1
4Shut Off Valves 2
5Motor Mounts
8Pump Plug1
Physical Specifications
Dimensions 60" x 84"
Height29"
Depth28"
Seating Positions 4
Weight Dry Lbs. 410
Weight Full Lbs. 1786
Water Capacity 165 gallons
Total Therapy Jets20

MARQUIS SPAS • RELAXING YOUR WORLD 18
Component Identification #
1so Boost Jets9
2Power Boost Jets4
4Cyclo Boost Jet1
5Cyclo Swirl Jet1
6Light1
7Air Control Valve1
8Heat Sensor 1
10 Suction Fittings 2
11 Bathers Panel 1
12 Auxiliary Control Panel 1
14 Floor Drain1
15 Filter Canister 1
16 Jet Selector Valve1
22 Ozone njector Fitting 1
Maximum Therapy System #
1Control Box & Heater 1
2Pump Unions 2
3Pump 1
4Shut Off Valves 2
5Motor Mounts
8Pump Plug1
9 120V GFC 1
Physical Specifications
Dimensions 78" x 78"
Height31"
Depth 30"
Seating Positions 6
Weight Dry Lbs. 475
Weight Full Lbs. 2226
Water Capacity 210 gallons
Total Therapy Jets15
MIRAGE LEISURE SERIES

MARQUIS SPAS • RELAXING YOUR WORLD 19
Component Identification #
1so Boost Jets9
2Power Boost Jets4
4Cyclo Boost Jet1
5Cyclo Swirl Jet1
6Light1
7Air Control Valve1
8Heat Sensor 1
10 Suction Fittings 2
11 Bathers Panel 1
12 Auxiliary Control Panel 1
13 Cascade Neck Jets3
14 Floor Drain1
15 Filter Canister 1
16 Jet Selector Valve1
18 Neck Jet Control Valve1
20 Geyser Jets3
22 Ozone njector Fitting 1
MaximumTherapy System #
1Control Box & Heater 1
2Pump Unions 2
3Pump 1
4Shut Off Valves 2
5Motor Mounts
8Pump Plug1
Physical Specifications
Dimensions 78" x 78"
Height31"
Depth 30"
Seating Positions 6
Weight Dry Lbs. 475
Weight Full Lbs. 2226
Water Capacity 210 gallons
Total Therapy Jets21
MIRAGE LX LEISURE SERIES
This manual suits for next models
19
Table of contents
Other Marquis Spas Hot Tub manuals
Popular Hot Tub manuals by other brands

Dimension One Spas
Dimension One Spas Arena Specifications

dellonda
dellonda DL88 manual

American Standard
American Standard WALK-IN BATH Installation instructions and owner's manual

American Standard
American Standard 2908.018 parts list

AquaTerra
AquaTerra Montecito owner's manual

Balboa
Balboa TP800/3 Quick reference card