05 HYS006874
This instrument must not be used on
uninsulated conductors at a voltage
greater than 250V ac rms. or 250V dc
Set the DMM at ACV function and a relevant
range.
Connect the plug of transducer with a DMM and
combined firmly.
Press the trigger to open transformer jaws and
clamp one conductor only, making sure that the
jaws is firmly closed around the conductor, then
read the reading from the digital display of DMM.
5.1
5.2
5.3
6. Maintenance
to keep the instrument clean, wipe the case with a damp
cloth and detergent, do not use abrasives or solvents.
Any adjustment, maintenance and repair shall be
conducted by a service personnel.
5. Ac Current Measurement
0403
3.1 General
CURRENT RANGE: 0.1A - 400A a.c. RMS
OUTPUT VOLTAGE LEVELS:
10mV/A: 1mV a.c. per 0.1 Amp a.c.
1mV/A: 1mV a.c. per 1 Amp a.c.
WORKING VOLTAGE:
600V CAT.II per IEC 1010 - 1
OPERATING TEMPERATURE:
0 to 50 <80% relative humidity°C °C
STORAGE TEMPERATURE: -20 to 60°C °C
TYPE OF SENSING:
induction coil sensing for AC current
MAXIMUM OUTPUT IMPEDANCE: 45Ω
MAXIMUM JAW OPENING: 29mm
MAXIMUM CONDUCTOR SIZE: 28mm
SIZE: 64(W)×143(L)×30(D)
WEIGHT: 185g
4. Precaution And Preparations
For Measurement
Dot not apply the voltage to the output
plugs.
Do not use or store this instrument in a high
temperature or high humidity environment
and do not store the unit indirect sunlight.
Do not measure current before the unit is
not combined with DMM.
If the instrument is used near noise
generating equipment, be aware that output
voltage may become unstable or get more
errors.
4.1
4.2
4.3
4.4
3.2 Electrical Specification
AccuracyRange
± ± 2.0% 0.5A
10mV/A
Frequency Response: 50-60Hz