Master audio TP2400 User manual

INSTRUCTIONS
MANUAL
TP2400
THREE
CHANNEL
AMPLIFIER
2.1 SIGNAL
PROCESSING
Advanced sound systems since 1972


Amate Electroacústica, S.L. desea agradecerle la conanza de-
positada en nuestros productos, esperando resultarán de su
plena satisfacción. Todos los productos MASTER AUDIO son
fabricados bajo estrictas normas de calidad, superando riguro-
sos controles de prestaciones y fatiga, garantizando un perfecto
funcionamiento incluso en condiciones extremas.
1 - CARACTERÍSTICAS GENERALES
2 - CONTROLES (Panel Frontal)
- Controles.
- Indicadores.
3 - CONEXIONES (Panel Posterior)
- Entradas de Señal.
- Altavoces.
- Red.
- Ventilación.
4 - FUNCIONAMIENTO
- Instalación.
- Sistemas de Protección.
- Mantenimiento.
5 - CARACTERÍSTICAS TÉCNICAS
6 - CERTIFICADO DE GARANTÍA
Para obtener el mayor rendimiento y la máxima garantía de
funcionamiento le aconsejamos lea detenidamente este Ma-
nual de Instrucciones, y dirigirse a su proveedor si precisa de
cualquier información no contemplada en este Manual.
El SISTEMA TP2400 2.1 ha sido concebido para cubrir múlti-
ples posibilidades de aplicación en locales musicales en general,
e incluye las prestaciones más exigentes incorporadas en los
sistemas profesionales, como la biamplicación, procesamiento
activo de la señal, ltros activos congurables, circuito soft-start,
limitadores de potencia y de clipping y múltiples sistemas de se-
guridad y protección.
- BIAMPLIFICACIÓN: El TP2400 dispone de dos amplica-
dores para las unidades de Medios-Agudos (Left-Right), y otra
unidad de amplicación de mayor potencia para las bajas fre-
cuencias (Subwoofer), cada una de ellas dotada de control inde-
pendiente de volumen.
- FILTROS ACTIVOS incorporados (tres, variables) que permi-
ten seleccionar la gama de frecuencia a reproducir por cada uno
de los sistemas acústicos, optimizando la respuesta para adap-
tarla a los sistemas de altavoces utilizados.
- La sección SUBWOOFER dispone además de interruptor
BOOST que al activarlo aplica un incremento de 6dB a 50Hz se-
guido de un ltro subsónico de 18dB/Oct, muy útil para reforzar
la respuesta en graves sin comprometer la potencia admisible
del subwoofer.
- El interruptor de FASE (0-180) permite invertir la fase eléctrica
del subwoofer y poder alinearla acústicamente con los sistemas
empleados para medios-agudos.
- Tres LIMITADORES ajustables de gran utilidad, (uno para cada
vía) permiten reducir la potencia máxima de cada uno de los ca-
nales de amplicación, bien para ajustarla al nivel especicado
de los altavoces empleados o simplemente para no sobrepasar
el nivel máximo acústico requerido en el local.
- El interruptor de puesta en marcha incorpora un elaborado cir-
cuito SOFT START que evita el pico de consumo que sobrecar-
ga/activa los magnetotérmicos, manteniendo unos segundos el
amplicador en “MUTE”, y activando el sonido lentamente para
evitar cualquier ruido o sobresalto en la fase de conexión.
- El LIMITADOR de CLIPPING incorporado en cada canal pro-
tege a los sistemas de altavoces de la distorsión por saturación
a máxima potencia.
- Cuenta con los SISTEMAS DE PROTECCIÓN necesarios
para garantizar un funcionamiento normal dentro de sus pa-
rámetros e incluso en situaciones anormales circunstanciales:
Cortocircuito, DC a la salida, temperatura, etc., todo ello inde-
pendientemente en cada canal gracias a su diseño modular. Un
Breaker rearmable protege totalmente la unidad en casos de so-
brecarga prolongada. Asimismo el TP2400 incorpora FILTRO de
RED para mejorar la inmunidad de emisiones parásitas a la red,
cumpliendo holgadamente con la directiva CE.
- El TP2400 es una unidad COMPACTA Y MUY VERSÁTIL que
permite ser fácilmente congurada para cualquier combinación
de altavoces de amplia gama y subwoofers, ofreciendo siem-
pre prestaciones y calidad comparables sólo a sistemas de alta
gama, mucho más caros y complejos.
CARACTERÍSTICAS GENERALES
ESPAÑOL01

Todos los ajustes del TP2400 se encuentran situados en el pa-
nel frontal. De acceso directo los ajustes básicos nivel/volumen
(subwoofer, left, right) y el interruptor de puesta en marcha.
Desmontando el panel frontal (central), aojando los dos tornillos
cau¬tivos que lo sujetan al chasis, tendremos acceso a todos
los ajustes que sirven para optimizar el TP2400 a los sistemas
acústicos conectados o a la instalación realizada, BOOST, FASE,
FILTRO (HPF) y LIMITER para el Subwoofer, así como FILTRO
(LPF) y LIMITER para cada uno de los canales Left y Right. Una
vez realizados volveremos a colocar el panel fron¬tal, evitando
que estos ajustes de mayor complejidad técnica queden acce-
sibles al uso diario.
INDICADORES. En el panel frontal se encuentran diversos in-
dicadores led que ofrecen información del funcionamiento de la
unidad:
a) El indicador iluminado AZUL indica la puesta en marcha.
b) El indicador iluminado ROJO indica la activación de los circui-
tos de protección.
c) Los indicadores iluminados VERDE (-24dB, -12dB) indican el
nivel entregado por cada uno de los canales.
d) Los indicadores iluminados AMBAR indican la actuación del
limitador correspondiente al canal afectado.
CONTROLES EN PANEL FRONTAL
DAB
C
Panel frontal en modo usuario
Panel frontal retirado para ajuste del sistema

a) Instalación. El TP2400 puede instalarse en Rack Standard
19”, ocupando 2 U (88.9mm.) de altura, o bien en cualquier es-
tante o mueble si se trata de instalación ja. En ambos casos hay
que procurar que la circulación de aire sea totalmente franca.
Evítese la instalación en muebles cerrados sin posibilidad de re-
novación constante de aire.
b) Conexión de Previos. Para conectar fuentes de sonido es
recomendable disponer de un Mezclador Profesional previo que
disponga de salidas de señal balanceadas. Las salidas de este
mezclador deben ser conectadas a la unidad TP2400 mediante
conector XLR, (pin 1 malla, pin 2 vivo, pin 3 retorno) para obte-
ner la mejor de las prestaciones. El cable a utilizar deberá ser
apantallado con 2 conductores (2 vivo, 3 retorno), mas el tercer
conductor que actúa como apantallamiento exterior (malla).
c) Conexión de las Cajas acústicas. Indistintamente podrán
utilizarse cajas acústicas de 4, 8 ó 16 Ohm, conexionadas en pa-
ralelo, respetando en cada caso la impedancia mínima del am-
plicador (4 Ohm por canal). No se recomiendan combinaciones
en Serie o Serie-Paralelo, que aunque no resultarían peligrosas
para la integridad del aparato, sí pueden ser perjudiciales para la
calidad sonora del sistema.
En las salidas de medios-agudos (satélites), se pueden conec-
tar a cada canal (Left o Right) sistemas de altavoces de amplia
gama (Full Range), siendo la potencia entregada de 500 W por
canal a 4 Ohms, equivalente a:
- 1 sistema acústico de 4 Ohm, con una capacidad mínima de
potencia de 500 W.
- 1 ó 2 sistemas acústicos de 8 Ohm en paralelo de una capaci-
dad mínima de potencia de 250 W cada uno.
- Ó 1 a 4 sistemas acústicos de 16 Ohm en paralelo, de una
capacidad de potencia mínima de 125 W cada uno.
En la salida de graves Subwoofer, se conectarán los sistemas
acústicos destinados a la reproducción de bajas frecuencias:
En este caso la potencia disponible para subwoofers es de
1.400 W sobre 4 Ohms, equivalente a 1 ó 2 subwoofers de 800
W / 8 Ohm unidad ó a 1 subwoofer de mínimo 1.400 W / 4 Ohm
(doble 15” ó 18”).
Destacar que, en ambos casos el dispositivo Limitador incluido
en cada vía permite adaptar sus potencias a cualquier sistema
acústico de inferior capacidad de potencia o a sus impedancias.
Para dichas conexiones deberá utilizarse manguera de dos con-
ductores de 4mm de sección mínima, aumentando la sección si
la distancia supera los 20 metros.
Procúrese mantener la polaridad +/- en toda la instalación. Una
inversión de fase en alguna de las unidades conectadas provo-
caría cancelaciones entre los sistemas acústicos, desmejorando
considerablemente la respuesta auditiva del sistema.
Importante: Si por cualquier circunstancia se produjera un cru-
ce entre alguna de las líneas de altavoces, el circuito de protec-
ción activaría de forma ja el Led indicador “Protection” (rojo),
con desconexión total de la salida de potencia correspondiente
al canal afectado hasta que la anomalía sea subsanada.
d) Ubicación. Las unidades de Medios Agudos (satélites),
deberán instalarse mediante soportes especícos a una altura
media superior a 2m (entre 2,5 y 4m). Respecto a las unidades
subwoofer, su mejor ubicación será en el suelo situándolas en
una zona central entre los canales izquierdo y derecho de los
satélites.
FUNCIONAMIENTO
CONEXIONES EN PANEL POSTERIOR
a) Entradas de señal. Las entradas de señal se efectúan por
conector XLR- Balanceadas, usando el Pin 2 (XLR) como vivo
(+), el pin 3 como retorno (-) y el pin 1 como malla (shield).
Muy importante: En el caso de no disponer de señal Ba-
lanceada, NO deberán puentearse los pins 1 y 3. El pin 1
debe dejarse sin conectar, el pin 2 es el vivo y el pin 3 es el
conectado a la malla del cable apantallado.
b) Altavoces. Las salidas de altavoces se efectúan mediante
conectores tipo BORNAS, recomendándose conductores multi-
lares de 4 mm de sección, RESPETANDO siempre la polaridad:
ROJO para el positivo (+) del altavoz y NEGRO para el negativo
(-). Las salidas LEFT y RIGHT son las utilizadas para la conexión
de las unidades de medios-agudos(satélites), destinando la sa-
lida SUBWOOFER a conectar los sistemas para reproducir las
frecuencias graves.
c) Conexión a la red. 230V. +/-10%, 50-60 Hz. La conexión
de red se efectúa mediante el cable adjunto IEC-/SCHUKO. Se
recomienda utilizar siempre el cable suministrado con el aparato,
por ser de la sección correspondiente a la potencia del TP2400.
d) Ventilación. El TP2400 se refrigera por aireación forzada me-
diante dos ventiladores ubicados en la parte posterior como en-
trada de aire, con salida por la rejilla frontal. En ningún caso de-
ben obstaculizarse estas aberturas que facilitan el paso de aire.
El ujo de aire es regulado por la Temperatura, manteniéndose al
inicio a medio caudal y aumentando la velocidad cuando son de-
tectados más de 55º en los sensores térmicos situados en cada
uno de los radiadores y en el transformador de alimentación.
D ABC

CARACTERÍSTICAS TÉCNICAS
Sensibilidad
Impedancia de entrada
Potencia de salida (1kHz - 0.1% THD) *
L & R
Subwoofer
Consumo a Máx. Potencia (en programa musical)
Respuesta en frecuencia
L & R
Subwoofer
Factor damping (1kHz@8Ohm)
Diafonía
Distorsión Armónica THD
Relación S/N
Dimensiones (AlxAnxP)
Peso (neto)
1.5 V para máxima potencia
20 kOhm
300 + 300 W @ 8 Ohms / 500 + 500 W @ 4 Ohms
800 W @ 8 Ohms / 1400 W @ 4 Ohms
6 A
70~140 Hz - 20k Hz (-3dB)
30~50 Hz - 90~140 Hz (-3dB)
L & R >280 , Subwoofer > 400
65 dB
< 0.05%
104 dB
88 x 482 x 440 mm (2U Rack 19”)
21 Kg
* Tono pulsante continuo de 20ms (0dB) / 480ms (-20dB) de
acuerdo con EIA RS-490 y IEC 60268-3(IHF A-202)
e) Protección. El TP2400 está dotado de avanzados sistemas
de protección, ampliamente experimentados:
- Soft-Start. En el momento de la Puesta en Marcha (Power),
se activa un circuito con retardo de la conexión que evita picos
de corriente durante esta transición inicial. Incorpora además un
Filtro de Red anti parasitario y un fusible rearmable (Breaker) que
actúa como protección primaria al producirse un consumo ex-
cesivo de la unidad.
- Cortocircuito. Si una o varias líneas de altavoces se cortocir-
cuitan (+/- cruzados), el Sistema desconectará indenidamente
el módulo de potencia correspondiente, tal como se ha descrito
con anterioridad.
- DC. Presencia de Corriente Continua a la salida de altavoces.
Un elaborado circuito testea la salida de potencia de cada uno
de los canales, desconectándolo si por cualquier anomalía entre-
gase corriente continua (DC) para proteger el altavoz.
- Temperatura. La protección por exceso de temperatura en los
módulos de potencia está controlada mediante sensores elec-
trónicos NTC de elevada precisión, los cuales activan el circuito
protector si se rebasan los límites establecidos (90 °C) y a su vez
ordenan una atenuación gradual de la potencia máxima entre-
gada, manteniéndola dentro de los parámetros máximos. Esta
situación puede indicar una anomalía en el sistema de ventilación
(obturado, averiado), o bien una circunstancia de trabajo anor-
mal producida por un continuado exceso de señal a la entrada.
- Ventilación. Los ventiladores están situados en el panel pos-
terior y disponen de dos velocidades de giro; la inicial que co-
rresponde al 50% y está activada permanentemente, y la total,
que corresponde al 100% y que se activa al detectarse en los
módulos de potencia o en el transformador de alimentación tem-
peraturas superiores a 55º C. Si por alguna circunstancia, como
por ejemplo, la obstrucción del circuito de aireación, o por ave-
ría en el ventilador, se produjera un incremento alarmante de la
temperatura (>90°C), un circuito de protección desconectaría la
señal de entrada (Led Rojo activado jo) con rearme automático
al recuperarse a la normalidad. Esta circunstancia exigiría la revi-
sión inmediata de la instalación o de los elementos que puedan
provocar la situación.
Restablecer la normalidad o resolver el problema de ventilación
será suciente para que automáticamente el aparato recupere
sus máximas prestaciones de potencia.
- Limiter. Un ecaz circuito Limitador Anti-Clip por vía protege la
salida de los altavoces contra la peligrosa presencia de Distor-
sión por Clipping, motivo principal de la mayoría de averías en
éstos (bobinas quemadas o cortadas). Más de 25 años incor-
porándolo en nuestros amplicadores han demostrado su e-
cacia, alargando signicativamente la vida útil de los altavoces y
transductores acústicos, sobretodo cuando se requiere trabajar
continuamente a plena potencia.
Además, y gracias a la posibilidad de ajuste manual de di-
chos limitadores (L & R + Sub), es posible adaptar la potencia
de salida de cada vía independientemente, a la capacidad de
potencia de los sistemas acústicos utilizados y según sea su
impedancia. Asimismo este ajuste permitirá también adaptarse a
las Reglamentaciones Municipales de Contaminación Acústica,
controlando automáticamente y con precisión el SPL máximo
autorizado en cada local.
- La humedad y el polvo son dos elementos nocivos para la vida
de todo aparato electrónico. Evítese en lo posible ubicaciones
bajo estas circunstancias.
- El mantenimiento básico se limitará a una revisión y limpieza
interior mediante aire a presión de las zonas más afectadas por
la corriente de aire generada por las turbinas de ventilación, al
menos una vez al año o siempre que se observe obturada la
rejilla frontal de salida de aire.

Amate Electroacústica, s.l. would like to thank you for the con-
dence you have placed in our products. We are sure they will give
you complete satisfaction. All MASTER AUDIO products have
been manufactured under strict Quality Controls and have sur-
passed rigorous performance and fatigue testing to guarantee
perfect operation even under extreme conditions.
1 - GENERAL FEATURES
2 - CONTROLS (Front panel)
- Controls.
- Indicators.
3 - CONNECTIONS (Rear panel)
- Signal Inputs.
- Speakers.
- Power supply.
- Ventilation.
4 - OPERATION
- Installation.
- Protection systems.
- Maintenance.
5 - TECHNICAL FEATURES
6 - CERTIFÍCATE OF WARRANTY
To obtain maximum performance and guaranteed operation,
please read this Instruction Manual carefully before making any
connection or putting the apparatus into operation. Ask your
supplier if you require any further information not included in this
Manual.
The TP2400 2.1 SYSTEM has been designed to cover a wide
range of general applications in music clubs. Its unique design
includes the most demanded features of professional P.A. sys-
tems, such as: bi-amplication, active signal processing, con-
gurable lters, soft-start circuit, anti-clip limiters and multiple
protection and safety systems.
- BI-AMPLIFICATION: The TP2400 incorporates a stereo am-
plier for the mid-high range (Left-Right) and a more powerful
Mono amplier unit for low frequencies (Subwoofer). Each ampli-
er is controlled by its own independent volume control.
- ACTIVE FILTERING: three adjustable built-in lters allow the
user to select the frequency range to be reproduced by the
speaker systems connected to each channel. The response is
therefore optimized for each speaker system.
- The SUBWOOFER section has also a BOOST switch, which
applies an increment of 6dB at 50Hz, and a subsonic lter (HPF)
of 18dB/oct. A very useful option when the response of the
subwoofer needs to be reinforced, without limiting the maximum
admissible power.
- Also in the subwoofer section, a PHASE (0-180) switch is
available to electronically invert the phase of the subwoofer, and
nd the best acoustical alignment with the mid-high satellite
speakers.
- Three adjustable LIMITERS (one per channel), allow to adjust
the maximum power delivered by each of the amplier chan-
nels. This allows adjusting the power delivered to the connected
speaker systems, either to match it with their maximum admis-
sible power or simply to not overpass the maximum acoustical
pressure needed in the installation.
- The unique SOFT START circuit in the power switch avoids
high inrush currents at power up by keeping the amplier in
MUTE for a few seconds and progressively activating the output
signal, avoiding any noise or sudden shock during the power up
phase.
- Each channel is equipped with a CLIP LIMITER, which pre-
vents the loudspeaker systems from reproducing distortion due
to amplier saturation at maximum power.
- The amplier is tted with extended PROTECTION SYSTEMS,
needed to guarantee a safe operation, even under temporary ab-
normal situations. The amplier is protected against shortcircuit,
presence of DC at the speaker outputs, overtemperature, etc.
Each protection is independent for each power module, thanks
to the amplier’s modular design. An automatic reset Breaker
fully protects the unit in case of continuous overload. Also, a CE
compliant mains lter improves the immunity to parasitic signals
in the mains.
- The TP2400 is a COMPACT AND VERSATILE unit which
can be easily congured for any combination of speakers and
subwoofers, getting the maximum performance of them, achie-
ving a sound quality equal to more complex and expensive sys-
tems.
GENERAL FEATURES
ENGLISH02

All the controls of the TP2400 are located on the front panel. The
basic controls (Power switch and volume control for left/right/
sub) can be accessed directly.
By removing the central front panel cover (unscrewing the two
screws that attach it to the front panel), the advanced con-
trols can be accessed. This set of controls is used to optimize
the TP2400 to the loudspeaker systems to be driven. For the
Subwoofer section BOOST, PHASE, HPF and LIMITER are avai-
lable. For the LEFT & RIGHT channels, LPF and LIMITER can
be adjusted. Once these controls have been set, the front panel
cover can be mounted again, to avoid and unintended change to
these sensitive controls.
INDICATOR LEDS. On the front panel, several leds supply with
basic information about the amplier function:
a) The BLUE led lights when the unit is powered ON.
b) The RED led is lit when a protection circuit is active
c) The GREEN leds (-24dB, -12dB) show the output level delive-
red by each amplier channel
d) The YELLOW leds are lit to show that the limiter of the corres-
ponding channel is activated
FRONT PANEL. CONTROLS
DAB
C
Front panel (user model)
Front panel removed (adjustment controls)

a) Installation. The TP2400 may be installed in a standard 19”
Rack, occupying 2 U (88.9mm) height, or on any shelf or location
if the installation is xed. In both cases make sure that the air ow
is not blocked in any way.
Do not install inside closed locations without good air circulation.
b) Connection of pre-amplier units. For sound sources con-
nection, a professional Mixer with balanced outputs is strongly
recommended. The outputs of this mixer should be connected
to the TP2400 using XLR connectors (pin 1 shield, pin 2 live, pin
3 return) to obtain the best performance. The connection cable
should be twin conductor and shielded.
c) Connection of Loudspeakers. Speakers of either 4, 8 or 16
Ohm may be used provided the minimum total impedance of the
amplier (4 Ohm per channel) is maintained. Connect speakers
in parallel for best results. Avoid combinations in series or series/
parallel. This will not cause any damage to the apparatus but can
be detrimental to the general quality of the system.
To the Left and Right outputs the Mid-High frequency louds-
peakers (Satellites) may be connected. The power delivered by
each of these outputs is of 500W at 4 Ohm, so the following
combinations may be used:
-1 Speaker of 4 Ohm nominal impedance with a minimum power
handling of 500W
-1 to 2 Speakers of 8 Ohm with a minimum power handling of
250W each, connected in parallel
-1 to 4 Speakers of 16 Ohm with a minimum power handling of
125W each, connected in parallel.
At the Subwoofer output, the speaker system for the reproduc-
tion of low frequency should be connected. The power delivered
at this output is of 1.400W at 4 Ohm, so 1 to 2 subwoofers of
800W at 8 Ohm or 1 subwoofer of 1.400W at 4 Ohm may be
used (e.g. 2 x 15” or 2 x 18”).
It is important to point out that the Limiter Adjust available for
each channel allows the user to match the output delivered by
the amplier to the power handling of the available loudspeakers,
when these ones have lower power handling.
For the loudspeaker connections, twin conductor cable with a
minimum section of 4 mm should be used, or even greater if the
distance between amplier and loudspeaker exceeds 20 m.
Polarity (+/-) should be maintained throughout the installation.
Phase inversion in any of the connected units will cause various
frequency cancellations that will adversely affect the sound res-
ponse of the system.
IMPORTANT: If for any reason a short-circuit may occur in any
of the speaker lines, the short-circuit protection circuit lights the
PROTECT LED (red) and completely cuts the power output of
the affected channel until the fault is corrected. This guarantees
protection of the speakers and power stages.
d) Location. The Mid-high frequency units (satellites) should be
installed on specic stands more than 2m high (between 2.5 and
4m). The best location for the Subwoofer units is at oor level in
OPERATION
BACK PANNEL. CONNECTIONS
a) Signal inputs. The signal inputs require a XLR-3 connector.
They are balanced using Pin 2 (XLR) as live (+), Pin 3 as return (-)
and Pin 1 as shield (chassis).
IMPORTANT: If balanced signal is not available, DO NOT
connect pins 1 and 3 together. Pin 1 should be left uncon-
nected and Pin 3 should be connected to the cable shield.
b) Loudspeakers. Loudspeakers are connected through BIN-
DING POSTS. 4 mm section multi -wire conductor are most
recommended, being the polarity as follows: RED for the po-
sitive (+) loudspeaker’s terminal and BLACK for the negative (-)
loudspeaker’s terminal. Outputs LEFT & RIGHT are available to
connect the satellites or the Mid-high. The SUBWOOFER output
is used to connect the low frequency reproduction speakers.
c) Mains 230V (+/-10%, 50-60Hz). The main connection is
done with the supplied IEC/SCHUKO cable. It is recommended
to always use the supplied cable, because it has the suitable
cross section to hold the power drawn by the TP2400.
d) Ventilation. The TP2400 is cooled by forced ventilation by
means of two fans located at the rear. The fans take the air in the
amplier from the back, and take it out through the grill on the
front panel. Do not block the air intakes and outlets. The air ow
is adjusted according to the temperature, starting at half speed
and increasing it when the power modules or the mains transfor-
mer exceed 55º.
D ABC

TECHNICAL FEATURES
Sensitivity
Input impedance
Output power (1kHz - 0.1% THD)*
L & R
Subwoofer
Max. Power Consumption (musical program)
Frequency Response
L & R
Subwoofer
Damping factor (1kHz@8Ohm)
Crosstalk
Harmonic Distortion TDH
S/N Ratio
Dimensions (HxWxD)
Net weight
1.5 V for full power
20 kOhm
300 + 300 W @ 8 Ohms / 500 + 500 W @ 4 Ohms
800 W @ 8 Ohms / 1400 W @ 4 Ohms
6 A
70~140 Hz - 20k Hz (-3dB)
30~50 Hz - 90~140 Hz (-3dB)
L & R >280 , Subwoofer > 400
65 dB
< 0.05%
104 dB
88 x 482 x 440 mm (2U Rack 19”)
21 Kg
* Continuous burst tone 20ms (0 dB) / 480ms (-20dB) in accor-
dance with EIA RS-490 and IEC 60268-3(IHF A-202)
an area between the left and right channel satellite units.
e) Protection. The TP2400 is equipped with advanced protec-
tion systems, which have been extensively checked.
- Soft-start. Connecting the power supply activates a delay cir-
cuit to prevent current peaks during this initial period. This power
supply circuit also includes an anti-parasite lter and an automa-
tic reset Breaker to protect against excess consumption.
- Short-circuit: If one or more speaker lines are short circuited
(+ connected to -) the system disconnects the corresponding
power module.
- DC. Presence of Direct Current at the speaker output. A spe-
cial designed circuit senses the power output of each of the
channels, disconnecting the power module to protect the louds-
peaker if a DC is detected
- Temperature. Protection against over-heating in the power
modules is controlled by a NTC sensor in contact with the heat
sinks. A protective circuit is activated if they pass pre-set limits
(90°C) resulting in a gradual reduction of the maximum power
within acceptable limits. This situation may indicate a fault in the
ventilation system (blocked or faulty) or abnormal working condi-
tions caused by continued excess input signal.
- Ventilation. The cooling fans are located on the back panel and
can operate at two speeds; the initial speed is at 50% of the maxi-
mum and will be the default. The full speed will be activated if any
of the temperature-sensed elements (power modules and trans-
former) heat over 55ºC. If for any reason, such as obstruction of
the cooling circuit or a fault in the cooling fans, the temperature
increases to dangerous levels (>90°C), the protection circuit will
disconnect the input signal (Red PROTECT LED lit constantly)
until normal conditions are restored. This circuit automatically re-
arms within a few minutes. In this case, immediately revise the
installation or elements that could have been the cause.
- Limiter. A highly efcient Anti-clip Limiter Circuit protects the
speaker output against the danger of Clipping Distortion, the
cause of the majority of breakdowns in speaker systems (burnt-
out or shorted coils). More than 25 years of using anti-clip tech-
niques have shown the efciency of this circuit, extending the
working life of loudspeakers when operating continuously at full
power.
In addition to this, the possibility of adjusting the limiter thres-
hold by the user (L&R + Sub), enables to independently adapt the
output power of each channel. The output power can be mat-
ched with the power handling of the available loudspeakers, de-
pending on their impedance. This adjust may also help to adapt
the maximum SPL level of the installation to the local regulations.
- Humidity and dust are the two most damaging elements for any
electronic device. Avoid use under these conditions.
- Basic maintenance is limited to inspection and cleaning of the
areas most affected by the air current generated by the cooling
fan at least once a year, or whenever any obstruction is observed
in the front air outlet grille.

WARRANTY CERTIFICATE
* Specications subjected to change without prior notice. NOV.2010
Amate Electroacústica, s.L, as the manufacturer of this unit, hereby, GUARANTEES for THREE
YEAR the perfect functioning of all the parts and components making up this equipment, as well as the performance qualities and tech-
nical features specied, with the right to the repair or replacement of all the parts presenting malfunctions or manufacturing defects, as
well as the Labour required for its recovery, provided that all the observations for the installation, operation and maintenance detailed in
this Manual have been strictly complied with.
Conditions exposed in the Certicate of Guarantee I Attach.
CERTIFICADO DE GARANTÍA
* Especicaciones sujetas a cambio sin previo aviso. NOV.2010
Amate Electroacústica, s.l. como fabricante de la presente unidad Garantiza por 3 años el perfecto funcionamiento de todas las par-
tes que conforman el aparato, así como las prestaciones y las características técnicas que se especican, con derecho a reparación o
substitución de todas las piezas que presenten malfunciones o defectos de fabricación, así como de la Mano de Obra necesaria para
restablecer la completa funcionalidad del producto.
Condiciones expuestas en el Certicado de Garantía Adjunto.

Amate Electroacústica, s.l.
C/. Perpinyà, 25
08226 - Terrassa (BCN) - SPAIN -
Tel. +34 735 65 65
Fax +34 735 60 48
export@master-audio.com
www.master-audio.com
Table of contents
Languages:
Other Master audio Amplifier manuals

Master audio
Master audio HD 2000 User manual

Master audio
Master audio SM1000 User manual

Master audio
Master audio PA Series User manual

Master audio
Master audio HD series User manual

Master audio
Master audio DX Series User manual

Master audio
Master audio DL Series User manual

Master audio
Master audio HD800 User manual
Popular Amplifier manuals by other brands

RF Concepts
RF Concepts Alpha 8406 user manual

DX Connection
DX Connection QSK 2500 instruction manual

LY International Electronics
LY International Electronics MINI60 owner's manual

Epifani
Epifani UL Series manual

One audio projects
One audio projects ERMSDCV2 user manual

Hifonics
Hifonics Nemesis NXi4404 user manual