eLinx Interpreter Programming Manual
1. CW Read – Reading to be programmed (If new installation set to “0”)
2. Number of digit to show – Number of digits to be shown (One to nine digits)
3. Start From digit – Starting digit
4. Main Display Units – Reading range to be used (Four multiplier options available)
5. IR Rotation Flag – Direction the measuring chamber spins with water flow (CCW-
Normal (MM) is most commonly used for Master Meter water meters)
6. Meter Decimal Point – Decimal place value to be shown (Also known as the Unit of
Measure. See Figure 5)
7. Flow Decimal Point – Decimal place value to be shown in the Rate of Flow (Also the
unit of measure for water flow) window
8. Meter Gear-Ratio – Found in 3G Tech NET**
9. Flow Ratio – Gear ratio of the meter (Gallons or Cubic Feet)
PLEASE NOTE: In order to view Rate of Flow, the desired unit of measure must be entered in
the Meter Gear Ratio field (Gallons is the most common Unit of Measure used).
After all parameters have been selected, attach the eLinx Programmer to the eLinx
Interpreter. There are multiple ways to attach to eLinx. Please see connectivity options listed
below:
1. Sensus TR/PL Sensor w/Wire
2. Itron Inline Connector
3. Nicor Connector
4. Bare Wires
Once connected click on the Write tab, located in the Unit Control menu. You are now able
to program all parameters selected for your eLinx Interpreter. You can verify programming
parameters within the Programming Status window, located to the right of the eLinx
Information window (See Figure 7).
Figure 7: Programming Status