ADJUSTMENT PROCEDURE
This tool is adjusted at the factory and no further adjustment should be necessary.
Should the tool, through extended use, require adjustment to compensate for wear
in parts, use the following procedure.
Adjustment Procedure:
1.
Close tool handles until pre-load is reached (this is the point at which the jaws butt)
2.
Measure the distance between the dots on the handle ends. 8" to 8 3/4" is the
correct distance for proper tool function.
3.
To increase the distance, remove the #6-32 eccentric lock screw and push up
eccentric from back to disengage. Rotate counter-clockwise to increase the
distance and clockwise to decrease the distance. Push down eccentric and re-
install the #6-32 lock screw in the appropriate hole which most closely yields t he
desired handle distance..
4.
Recheck the set distance after making three crimps.
5.
Check the crimps with the Go/No-Go gauge provided. If crimps do not pass testing,
the tool is likely worn and should be replaced.
Maintenance Procedure:
1.
Check tool calibration at least daily. It is recommended that the tool be checked
before the first crimp and after the last crimp of the day.
2.
Never exceed the specified handle distance when adjusting your tool. Premature
wear will result.
3.
Lubricate linkages on a regular basis to maximize tool life.
Customer Service:
203-488-8665 ext. 201
Eccentric
6945366 Multi-Head Crimp
Tool for PEX Copper Rings
To insert or remove
dies, open tool fully
and push up plunger
pin from bottom.
Correct Distance
8" - 8 3/4"