Operating Instructions WNS3U-W
MaxLite 120-277V Network (Bluetooth) 3-button Wall Switch
• To reduce the risk of death, personal injury or property
damage from fire, electric shock, falling parts, cuts/abrasions,
and other hazards read all warnings and instructions included
with and on the fixture box and all fixture labels.
• Before installing, servicing, or performing routine maintenance
upon this equipment, follow these general precautions.
• Commercial installation, service and maintenance of luminaires
should be performed by a qualified licensed electrician.
• DO NOT INSTALL DAMAGED PRODUCT!
Models: WNS3U-W
Features:
• Bluetooth Wall Switch that can be linked to a group of lights
using the c-Max App (iOS and Android)
• Enable ON/OFF and Dimming
• Compatible only with MaxLite c-Max Network Controls
• Purpose of control: Operating Control, Electronic Controller
Switch.
• Construction of control: Independently Mounted for Flush
Mounting.
®
General Safety Information
Wiring Diagram
Picture is for illustration
purposes only.
Your model may vary.
Specifications:
Voltage: 120-277VAC, 50/60Hz
Wire Strip Length: 16mm (5/8 in.)
Transmit Line Distance: 100ft
(Bluetooth Transmit: 100ft Max)
Operating Temperature: 32°F-104°F (0°C to 40°C)
Rated Impulse Voltage: 4000V
Pollution Degree: 2
Type of Action: Type 1 Action
WARNING: To avoid fire, shock, or death. Turn off power at circuit breaker or fuse and test that power is off before wiring.
1. Remove wall plate, switch mounting screws.
2. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
3. There are three wiring connections on the switch, these are marked HOT, NEUTRAL, GROUND.
4. Disconnect the wires from the existing switch
5. Connect the green wire to the GROUND terminal.
6. Connect the white wire to the terminal marked NEUTRAL.
7. Connect the black wire to the terminal marked HOT.
8. Check connections to be sure they are tight and no bare conductors are exposed.
9. Insert the switch into the outlet box carefully.
10. Make sure the switch to the box using the supplied screws.
11. Attach the wall plate.
12. Restore power to the circuit breaker and test the system.