3.For non-standard VESC firmware or other normal PWM
ESCs:
Data Source:
Speed sginal is detected by motor phase wire or hall sensor wire or VESC. Please
select 【Data Source】in remote manual and make sure hardware is connected
correct and well. The original acquisition speed signal is the electrical speed of the
motor (ERPM). Then remote will convert it to RPM or Speed and display.
Distance:
When【Data Source】is set to【Motor Wire】or【Hall Sensor】, the distance is the
accumulation of the product of speed and time per 0.1 second.
When【Data Source】is set to【VESC】, remote and receiver will read VESC’s ABS
data by UART port and calculate it to distance and display.
When you want to reset Distance, select【Dist. Rst.】and long press Function button,
then Distance will start from 0.
Main battery voltage display:
When【Data Source】is set to【VESC】, it will obtain VESC voltage information by
UART port; Otherwise, voltage information is obtained by BAT port on receiver PCB.
Please make sure receiver GND and your main battery GND are connected(common
ground).
If receiver is not connected to main battery or VESC UART port, remote will not display
anything about main battery.
If receiver gets voltage information, remote will show voltage in bars according to
preset 【Batt. Type】and 【Batt. Ser Num】.
Under the voltage bar on remote screen, it’s marked【xx Batt.】. “xx” means current【Batt.
Ser Num】value, please check if it’s same as your battery specification.
If【Batt. Type】or【Batt. Ser Num】is set different from your battery’s actual value, voltage