McAlpine Hussmann RHR2 User manual


CONTENTS
Pre Installation _____________________________
Cabinet Footprint and Cross Section 3
Technical Data Sheet 4
Wiring Diagram typical) 5
Receiving Cabinets 6
Operating Environment 7
Installed Position 7
Mechanical Protection 8
Handling Cabinets 8
Installation _____________________________
Positioning 9
Electrical Installation 9
Cabinet Installation _____________________________
Start Up 10
Loading 10
Temperature Adjustment 11
Temperature Checking 11
Fittings and Accessories 11
Maintenance _____________________________
Cleaning 12
Regular inspection 13
Replacement of Thermal Cut-out 14
Replacement Parts 15
Disposal of the Cabinet 15
Risk Analysis _____________________________ 16


RHR2 Hex Yes
Watts
Amps
Watts
Amps
Watts
Amps
RHR2 Hex 1034 4.31 2423 10.10 1034 4.31
Number of
Control
Thermostats
Canopy
Thermostat
Deck
Thermostat
Red Light
Thermostat
Green Light
Thermostat
RHR2 Hex 4 60C 45C 40C 30C
RECOMMENDED SET POINT PARAMETERS
Effective : 8 December 2010 Version : 1.1A
ELECTRICAL LOAD (240 Volts)
Phase 1 Phase 2 Phase 3
+65C 3 Yes
Product code & length
Product Data
Self Service
Product temp.
o
C
Number of Phase
circuits
Saftey Indicator
Lights
RHR2 Hex
2 Tier Chicken Island
McAlpine Hussmann reserves the right to change the document contained herein and any revisions without prior notice.
This document contains information that is of a confidential nature and is only for its intended recipients.
If you are not the intended recipient, you must not peruse, use, disseminate or copy this document or any attachment.
Ratings are affected if air flow pattern is altered by aisle draught exceeding 0.2m/s or shelving layout altered from standard layout.

5
RHR Hot Hex________________________________________________________________________________ Installaon Manual
Hussmann Refrigeraon______________________________________________________________________________________
Wiring Diagram
CONNECTOR
TERMINAL
N
E
MCB
EARTH
1000W
CANOPY ELEMENT
500W
500W500W
500W
HALOGEN LAMPS
CANOPY
OVERLOAD
THERMAL
216°
500W
1000W
500W
OVERLOAD
THERMAL
R1
1000W
500W
500W
216°
HALOGEN LAMPS
SHELF
A1
1A
FUSE
UPPER THERMOSTAT
T°
T°
LOWER THERMOSTAT
MEASURED
WATTS AMPS
A2
A3
DECK ELEMENT
SHELF ELEMENT
1034
2423
1034
A1
A2
A3
4.3
9.8
4.3
2.5mm
5 CORE
FLEX
C1
1A FUSE
SWITCH
CONTROL
53°C HOT THERMOSTAT
T°
30°C COLD THERMOSTAT
T°
RED
INDICATOR
GREEN
INDICATOR
}OPTIONAL
RCD
240V
OPTIONAL

6
RHR Hot Hex________________________________________________________________________________ Installaon Manual
Hussmann Refrigeraon______________________________________________________________________________________
Receiving Cabinets
Cabinets will always be dispatched in good condion. Always inspect the cabinet and packaged
accessories for damage. Note any damage on the carrier’s consignment note prior to signing.
For concealed damage that is found later, nofy Hussmann in the relevant country within 3 working
days. Any issues will be addressed and reced as applicable.
Australia: Hussmann Ltd
Email: [email protected]
Ph. 1300 36 38 40
New Zealand: McAlpine Hussmann Ltd
Tauranga
Ph. +64 7 578 0965
NOTE
Please provide a photographic record of any damage found along with
the cabinet serial number and a brief descripon of the damage.
A check should also be made to ensure that all loose parts listed on the outside packaging are present and
undamaged.
NOTE
Any shortages will follow the same procedure as concealed damage.

•
•
•
•
•

•
•
•
•

•
•
•
•
•

•
•
•
•
•
•

•
•
•
•
•
•
•
•
•

•
•

•



Table of contents
Popular Commercial Food Equipment manuals by other brands

Lotus cooker
Lotus cooker CWK-94ET Instructions for installation and use

Henny Penny
Henny Penny FlexFuison GOLD FGE-615 installation manual

CASO DESIGN
CASO DESIGN 696 Original operating manual

Lincat
Lincat SEAL PBG5 Installation and user instructions

Gemm
Gemm Delice Series Instructions for use

Henny Penny
Henny Penny FlexFusion FPG-615 Operator's manual