McLelland MAP-1200PRE User manual

6 Source /6 Zone Multi-room
Controller
MAP-1200PRE
OWNERS MANUAL
POWER
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6
MAP-1200PRE
6 SOURCE/6 ZONE MULTIROOM CONTRO LLER

2

3
McLELLAND MAP-1200PRE is a functional 6x6 matrix controller,
easy-to-install, highly compatible, expandable and used-friendly audio
distribution system. With few simple steps to install, it provides up to 18 zones
which all can be controlled by packaged keypads or IR remote controller.
Six line-level inputs are provided where to any line-level music source such as a
CD-player, Tuner, MP3 player, smartphone or other devices can be connected.
An Optical digital input to manage the sound of a flat screen or a CD player to
have high resolution of sound quality to each output zone.
Simply determine the different output power of amplifiers to suit the demand
of each output zone, so every audiophile in every zone can use IR controller or
keypads to enjoy the powerful audio. High functionality and performance bring
you musical enjoyment just the way you want it.
* 6 Line input sources, including RCA, Stereo 3.5mm and OPTICAL.
* Provides 6 output zones.
* Keypad to control each output zone.
* Enable control over Ethernet TCP/IP.
* RJ45 Ethernet port for the wired connection to the local network.
* Another RJ45 Ethernet expansion port for connecting with smart TV or other
device.
* RS-232 port allows 2-way communication with the Home Automation system.
* Built-in IR receiver & IR remote controller for Source
select/Volume/Treble/Bass.
* 12V DC trigger output to external device when the zone is power on.
* Expandable up to 18 Zones by additional 2 units.
* 6 LEDs for 6 zones Power On, Standby and Mute.
INTRODUCTION

4
SPECIFICATION
PACKAGE CONTENTS
S/N Ratio
THD
Frequency Response
Input Impedance
Input Sensitivity
Crosstalk
Output Impedance
Output Level
Trigger Out Voltage
Infrared Frequency
Input Connectors
Output Connectors
Network Connector
Power Supply
Power consumption
Dimensions
Weight
-110dB
0.05% (1V)
20Hz - 20KHz (-0.5dB)
>47 K Ohms
1V
-75dB (@1kHz)
100Ohms
3V
DC +12V
38kHz
RCA, 3.5mm stereo, OPTICAL
Terminal Block
RJ-45, Standard 10/100Mb
DC 15V/1.6A
24 W, Max.
440 mm x 44 mm x 196 mm (WxHxD)
2Kgs
* 6x6 Controller
* Rack Mounting Ears – 2 (Installed on Controller)
* Terminal Blocks – 12 (Installed on Controller)
* External Adaptor
* User Manual
There is an optional package for additional accessory, including:
* Remote Control
* Expansion Ribbon Cable
* Keypad Connection Hub and Decora Wall-plate
* PoE Keypads with built-in IR RX and Decora Wall-plates – 6
If these optional package is needed, please contact your local dealer.

5
POWER
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6
MAP-1200PRE
6 SOURCE/6 ZONE MULTIROOM CONTRO LLER
FRONT PANEL
REAR PANEL
1. Power ON/OFF/ STANDBY
Depress the power button to turn on the
system. Press it again to release the latch
and power the unit off.
Note that even the Master Controller is
powered on, each zone will remain in
Standby mode until the zone
keypad is activated.
1. PRE-AMP OUTPUT
Stereo Line level output on each zone.
Connect to the input of amplifiers or
powered speakers.
2. SOURCE INPUTS
Source1~3 : RCA Stereo Input
Source4~5: 3.5mm Stereo Input
Source6: OPTICAL Digital Input
3. TRIGGER OUTPUT
When the zone is activated, the
corresponding jack will output 12VDC to
trigger other device.
4. IR EMITTER
IR Outputs to control sources
5. KEYPAD
RJ-45 jack Connects to the keypad hub
for 6 keypads.
6. MASTER/SLAVE SWITCH
Set the unit ID when connecting multi
Controller systems
2.Standby/Zone ON LED
These six LEDs illuminate to indicate the
status of each zone.
Blue: In Standby mode.
White: In Activate mode.
Blue/White: In Mute mode.
1
2
1
2
3 4 5
6
7 8
10
1211
9
7. AGC
Automatic Gain Control, brings low level up to a
present-level.
8. ETHERNET/RS232 SWITCH
ETHERNET: When the amplifier connects to
Ethernet.
RS232: When the amplifier control by PC or
Control Device via RS-232 port.
9. ETHERNET PORTS
Dual LAN ports, one connects to the LAN port of
local router. Another connects to network
TV or other device which requires Ethernet.
10. RESET
The RESET button is used to reset the
ETHERNET back to factory default settings.
11. EXPANSION IN/OUT PORT
Expandable to 18 zones with 3 x Multi-zone
Controller systems.
12. DC INPUT
Connect the supplied DC adapter to the DC IN
jack, and then plug it into a standard household
outlet

6
1
3
5
6
7
2
7
4

7
1
7
2
5
6
3
4
3

The MAP-1200PRE provides 6 x stereo unbalanced line level source inputs
which can be accessed by any zone. Inputs 1~3 provide RCA jacks for
connecting the audio sources with RCA outputs.
Inputs 4 and 5 provide inputs on 3.5mm stereo jacks and input 6 also provides
one Digital Optical input for digital source like TV ARC, DVD and CD players or
cable/ satellite boxes.
Always use good quality shielded RCA cables to connect sources to the
MAP-1200PRE and keep RCA cables as short as possible to avoid RF interfere.
8
MAP-1200ED
RCA 3.5mm Stereo
controller

The MAP-1200PRE comes with 6 POE enabled keypads. This allows for source
control from each specific zone as well as IR routing to the appropriate source
devices once selected. The MAP-1200PRE also comes with a hub that allows for
all 6-keypads to be connected to the amp via Cat5e/6.
9
ZONE-1
ON ON OFF
1 2 3
ZONE-2
ON ONOFF
1 2 3
ZONE-3
ON OFFOFF
1 2 3
ZONE-4
ONONOFF
1 2 3
ZONE-5
ON OFFOFF
1 2 3
ZONE-6
ONOFFOFF
1 2 3

There are two Infrared (IR) emitter outputs on the rear panel. These outputs are
used to control the connected source components remotely through the
MAP-1200PRE IR system.
For example, connect an IR emitter to IR Emitter output jack of the controller,
and then connect the flasher to the IR receiver window on one of connected
sources. Now you can use the source remote control in any zone and control
your source through the keypads remotely. The keypad should have the
corresponding source selected for the IR to work. Repeat this for another
Infrared (IR) enabled sources for complete IR source control.
10
Source 2-DVD
IR Emitter from
Source 2 port
Power
IR Signal
Grounding
IR +
IR -
FRONT BACK
reserved for cascading units
INFRARED EMITTER OUTPUTS

The MAP-1200PRE allows 6 sources to be distributed to up to 18 zones on 3
different units using the provided ribbon cable to connect between units. To do
this first each unit needs to be addressed according using the MASTER/SLAVE
switch. There are 3 positions for this, Master, Slave 1, and Slave 2 which help
to identify each unit.
11
Once each unit is correctly addressed, use the provided ribbon cables to connect
the OUTPUT of the original MASTER unit into the INPUT of Slave 1. To cascade
the sources into a third unit, using the provided expansion ribbon cable, go out
of the OUTPUT port from the device addressed as SLAVE 1 INTO the INPUT port
of the device addressed as SLAVE 2.
Master
SLAVE 1
SLAVE 2
CASCADING SOURCES INTO ADDITIONAL ZONES

12
CONNECTION DIAGRAM
There are two RJ-45 jacks on the rear panel of this amplifier for the connection to
Ethernet.
Please use a good quality Cat5e/5 cable, and follow the connecting diagram
below.
1. Connect the LAN port on the rear panel of controller to the local Wi-Fi Router.
The Ethernet connection mainly for Wi-Fi control via APP or other control devices.
2. Connect another port (TO DEVICE) on the rear panel of controller to the smart
TV or other Network devices.
The port simply works as SWITCH function as long as the LAN1 port enabled to
Ethernet.
Note: When controlling via ETHERNET, please make sure the ETHERNET/RS232
switch is set at ETHERNET position.
ETHERNET PORTS INSTRUCTION
MAP-1 20 0PRE

13
The controller and APP are easy to install and connect to the local network,
simply connect the RJ-45 IN port to the router via Cat5 cable, and also make
sure your smart devices connect to the same local network. After connecting the
controller to the router by Cat5 cable, the controller will connect with the local
network automatically.
In case, having the problem for connecting to the network, please check the
position of switches on the rear panel.
INTEGRATED NETWORK
1.Open the IE web browser of PC, log in to the WEB configuration page of local
Router to find the IP address of MAP-1200PRE (shown as below)
Please switch to MASTER and ETHERNET.
Note. Please do not press “Reset” button.
Note. Please do not connect the Ethernet port of MAP-1200PRE to the computer
directly.
MAP-1200PRE

14
2. Using “Advanced_IP_Scanner” software to find the IP address.
Please visit www.advanced-ip-scanner.com for free download.
Then enter the IP address of MAP-1200PRE to the IE browser (shown as below),
ensure the Serial Configure is 9600,n,8,1. After finishing this step, MAP-1200PRE
could be controlled through the local Network.

Download free software “PuTTY” Tool from the internet to control the device.
Operation diagram as below:
15

Click Telnet, enter the IP address of MAP-1200PRE and port: 8080.
Click Open.
When the IP address connected, the operation diagram shows as below:
Key in the command code to control MAP-1200PRE.
For the detail of command codes, please find the RS-232 command codes in this
instruction manual.
16

RS232 CONTROL
The MAP-1200PRE provides an RS-232 serial port connection located on the
back panel and uses a USB-to- Serial Comm cable connection. The
MAP-1200PRE supports bi-directional RS-232 communication with third party
automation systems. All keypad and remote control operations can be controlled
via RS-232 in addition to system expansion up to 18 zones or 3 MAP-1200PRE
units linked together using the included 18 pin expansion cable.
Using free software “PuTTY” Tool to control the device. Operation diagram as
below:
Note: Set the switch to RS232 position.
Baud Rate 9600, 8, N, 1 , DB9 Connector Pin out, Tx, Rx, GND
17

Click Serial, check the COM port and enter the Baud rate 9600.
Click Open.
When the IP address connected, the operation diagram shows as below:
Key in the command code to control MAP-1200PRE.
Note: To find the information for the COM port, please open the device manager
of the computer, shown as below:
18

MAP-1200PRE RS-232 CONTROL CODES
(Baud Rate: 9600,8,N,1 , DB9 Connector Pin out, Tx, Rx, GND)
'CR':Carriage Return (0x0D)
Not case sensitive
Control Command Structure <xxPPuu'CR'
Reply Control Command Structure >xxPPuu'CR'
xx: Represent control command code
10 :All zones of host computer 1
20 :All zones of host computer 2
30 :All zones of host computer3
11 : Zone1 of host computer 1
12 : Zone2 of host computer 1
13 : Zone3 of host computer 1
...............
PP: Represent Control action code
PR:Power control
PR00:Power off
PR01:Power on
MU:Mute control
MU00:Mute off
MU01:Mute on
DT:Do Not Disturb control
DT00:DT control off
DT01:DT control on
VO:Volume control
VO(00-38):Volume control
TR:Treble control
TR(00-14):Treble control
BS:Bass control
BS(00-14):Bass control
BL:Balance control
BL(00-20):Balance control
CH:Source Channel control
CH(01-06):Source control
Ask command structure(1) ?xx'CR'
xx: Represent control command code
10 :All Zones of host computer 1
20 :All Zones of host computer 2
19

30 :All Zones of host computer 3
11 :Zone1 of host computer1
12 :Zone2 of host computer1
13 : Zone3 of host computer1
21 : Zone1 of host computer2
22 : Zone2 of host computer2
23 : Zone3 of host computer2
...............
Reply Command: >xxaabbccddeeffgghhiijj'CR'
aa:PA Control status
bb:Power Control status ([5]:Backup Zone Power Status (only on zone)
cc:Mute Control status
dd:DT Control status
ee:Volume Control status
ff:Treble Control status
gg:Bass Control status
hh:Balance Control status
ii:Source Control status
jj:The connection status of line control(00:unconnected 01:connected)
Ask command structure (2) ?xxPP'CR'
xx: Control Command Structure
10 :All Zones of host computer 1
20 :All Zones of host computer 2
30 :All Zones of host computer 3
11 : Zone1 of host computer 1
12 : Zone2 of host computer 1
13 : Zone3 of host computer 1
14 : Zone4 of host computer 1
15 : Zone5 of host computer 1
16 : Zone6 of host computer 1
...............
PP: Represent Control action code
PA:PA Control
PR:Power Control
MU:Mute Control
DT:DT Control
VO:Volume Control
TR:Treble Control
BS:Bass Control
20
Table of contents
Popular Controllers manuals by other brands

Emerson
Emerson Asset Management Tag Installation, operation and maintenance manual

Barco
Barco TransForm A Brochure & specs

Toshiba
Toshiba V Series user manual

Emerson
Emerson Bettis Q series Installation, operation and maintenance manual

Gruetzner
Gruetzner Lubricus LUB-C-1 user guide

Pixsys
Pixsys ATR226 user manual