FPD310-FV Operating Manual
Freespace High Sensitivity PIN Photo Detector Unit
(400 1000nm)
Product Specifications
Rise Time 0.7 ns
Gain – Setting 1
– Setting 2
5x10
4
V/W
5x10
2
V/W
Dark State Noise Level 90 dBm
NEP (calculated) 30 pW/Hz
1/2
Output Connector SMA
Output Impedance 50 Ω
Device Dimensions (mm) 60x50x27
Output Coupling AC
Optical Input Freespace
Supply Voltage +9 to +20 V
Current Consumption 250 mA
Max. Incident Power 2 mW
Operating Temperature 10 40 °C
Spectral Range 400 1000 nm
Detector Diameter 0.4 mm
Frequency Range 1 1500 MHz
3dB Bandwidth 10 900 MHz
0
0, 1
0, 2
0, 3
0, 4
0, 5
300 400 500 00 700 800 900 1000
Wave leng t h ( nm)
Spectral Responsitivity (A/W)
Am Klopferspitz 19, 82152 Martinsried, Germany
Phone +49 89 189166 0, Fax +49 89 189166 11
http://www.menlosystems.de
25.06.2007
Page 2/2
Packing Information
When unpacking your FPD310 FV, please check that the case contains the following items:
•1x FPD310 FV Detector (with markings “FPD310” / “400 1000nm”)
•1x Envelope with manual and test report
Setup and Operation
•After unpacking, connect the power supply to the detector as depicted in the
following sketch; refer to technical drawings and labelling of the device to locate
the respective connectors:
Best performance of the detector can be achieved when using a linear regulated
power supply. Note that switched power supplies may introduce switching noise
that could potentially carry through to the output signal.
•Connect Signal Out (SMA jack) to a suitable monitoring device, e.g. oscilloscope or RF spectrum
analyzer, with 50Ω impedance.
Mount the device firmly in your setup using the mounting holes (at least one of the two holes
through the device or M4 threaded hole at the side). Please note that when the device is not
mounted properly, involuntary displacements during operation might occur, leading to uncontrolled
reflections from the device.
•Switch on the power supply and monitoring device, and apply a light source to the photo diode.
•The FPD310 FV can be attenuated by 20dB operating the switch beneath the top with a small pen.
Maintaining the FPD310-FV
There are no serviceable parts in the FPD310 FV. The housing may be cleaned by wiping with a soft
damp cloth. Do not use any alcohol or organic solvent to clean the mechanical parts. The window of the
photo diode should only be cleaned using isopropyl alcohol and optical grade wipes.
If you suspect a problem with your FPD310 FV please contact Menlo Systems and technical support will
be happy to assist you. For service requests, please make sure to provide the serial number of your
device. For storage and shipping, please use the case your detector was shipped with.

Other Menlo Systems Security Sensor manuals

Menlo Systems FPD510 User manual

Menlo Systems

Menlo Systems FPD510 User manual

Menlo Systems APD210 User manual

Menlo Systems

Menlo Systems APD210 User manual

Popular Security Sensor manuals by other brands

Visonic MP-802 K9-85 PG2 installation instructions

Visonic

Visonic MP-802 K9-85 PG2 installation instructions

Duramaxx Powerpoint manual

Duramaxx

Duramaxx Powerpoint manual

KPS KPS-DT100 instruction manual

KPS

KPS KPS-DT100 instruction manual

Bosch SMT500 operating instructions

Bosch

Bosch SMT500 operating instructions

Essence Care Home user guide

Essence

Essence Care Home user guide

Potter PAD200-DUCTR installation manual

Potter

Potter PAD200-DUCTR installation manual

Risco Wireless VITRON RWT6G installation instructions

Risco

Risco Wireless VITRON RWT6G installation instructions

System Sensor 2300TB Installation and maintenance instructions

System Sensor

System Sensor 2300TB Installation and maintenance instructions

ESP RHD212 installation manual

ESP

ESP RHD212 installation manual

Emerson Rosemount 2160 quick start guide

Emerson

Emerson Rosemount 2160 quick start guide

Optex AX-100TFR Series installation instructions

Optex

Optex AX-100TFR Series installation instructions

B.E.G. LUXOMAT LC-Click-N 140 Installation and operation instruction

B.E.G. LUXOMAT

B.E.G. LUXOMAT LC-Click-N 140 Installation and operation instruction

Leuze electronic MLC 300 Series manual

Leuze electronic

Leuze electronic MLC 300 Series manual

AECO SMC-12 NO R1 AGD1 operating instructions

AECO

AECO SMC-12 NO R1 AGD1 operating instructions

Crow FREEWAVE FW-P100 installation instructions

Crow

Crow FREEWAVE FW-P100 installation instructions

GTO LOOPDT1 reference guide

GTO

GTO LOOPDT1 reference guide

PCB Piezotronics 200C50 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 200C50 Installation and operating manual

Agilent Technologies G3437A installation instructions

Agilent Technologies

Agilent Technologies G3437A installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.