FPD510 Operating Manual
Fiber coupled High Sensitivity PIN Photo Detector Unit
(850-1650 nm)
Product Specifications
Rise Time
2 ns
Gain
4x104V/W
Dark State Noise Level
-120 dBm (5-200 MHz)
-80 dBm (0-5 MHz)
NEP (calculated)
3 pW/Hz1/2
Output Connector
SMA
Output Impedance
50 Ω
Device Dimensions (mm)
60x50x27
Output Coupling
DC
Optical Input
SMF28, FC/APC
Supply Voltage
+8 to +15 V
Current Consumption
50 mA
Max. Incident Power
10 mW
Operating Temperature
10-40 °C
Spectral Range
850-1650 nm
Fiber Connector
FC/APC
Frequency Range
0-250 MHz
3dB-Bandwidth
0-200 MHz
0
0,2
0,4
0,6
0,8
1
800 1000 1200 1400 1600 1800
Wavelengt h (nm)
Spectral Responsitivity (A/W)
Am Klopferspitz 19, 82152 Martinsried, Germany
Phone +49 89 189166-0, Fax +49 89 189166-11
http://www.menlosystems.de
05.11.2008
Page 2/2
Packing Information
When unpacking your FPD510, please check that the case contains the following items:
1x FPD510 Detector (with markings “FPD510” / “850-1650nm”)
1x Envelope with test report and this manual
Setup and Operation
After unpacking, connect the power supply to the detector as depicted in the
following sketch; refer to technical drawings and labelling of the device to locate
the respective connectors:
Best performance of the detector can be achieved when using a linear regulated
power supply. Note that switched power supplies may introduce switching noise
that could potentially carry through to the output signal.
Connect Signal Out (SMA jack) to a suitable monitoring device, e.g. oscilloscope or RF-spectrum-
analyzer, with 50Ω impedance.
Mount the device firmly in your setup using the mounting holes (at least one of the two holes
through the device or M4-threaded hole at the side). Please note that when the device is not
mounted properly, involuntary displacements during operation might occur, leading to uncontrolled
reflections from the device.
Switch on the power supply and monitoring device, and connect the FC/APC connector to your light
source. Please note that only FC/APC connectors may be used for mating.
Maintaining the FPD510
There are no serviceable parts in the FPD510. The housing may be cleaned by wiping with a soft damp
cloth. Do not use any alcohol or organic solvent to clean the mechanical parts. The FC/APC fiber
connector may only be cleaned using appropriate cleaning tools.
If you suspect a problem with your FPD510 please contact Menlo Systems and technical support will be
happy to assist you. For service requests, please make sure to provide the serial number of your device.
For storage and shipping, please use the case your detector was shipped with.

Other Menlo Systems Security Sensor manuals

Menlo Systems FPD310-FV User manual

Menlo Systems

Menlo Systems FPD310-FV User manual

Menlo Systems APD210 User manual

Menlo Systems

Menlo Systems APD210 User manual

Popular Security Sensor manuals by other brands

Siemens FDOOT271-O Mounting

Siemens

Siemens FDOOT271-O Mounting

PCB Piezotronics 320C03 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 320C03 Installation and operating manual

SmartSafe iSmartE VP01 user manual

SmartSafe

SmartSafe iSmartE VP01 user manual

Treasure Cove Vibra-Quatic 320 manual

Treasure Cove

Treasure Cove Vibra-Quatic 320 manual

PCB Piezotronics ICP W138A10/-0018 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP W138A10/-0018 Installation and operating manual

Linear 2GIG-GB3-433 installation instructions

Linear

Linear 2GIG-GB3-433 installation instructions

Thermo Scientific Surveyor PDA Plus Hardware manual

Thermo Scientific

Thermo Scientific Surveyor PDA Plus Hardware manual

Heiman 2 BEAMS installation guide

Heiman

Heiman 2 BEAMS installation guide

Lena Lighting WSED414 HIM14 manual

Lena Lighting

Lena Lighting WSED414 HIM14 manual

UniPOS FD 7110 instruction manual

UniPOS

UniPOS FD 7110 instruction manual

Fast Aqua M300 D operating instructions

Fast

Fast Aqua M300 D operating instructions

Incon TS-LLD installation guide

Incon

Incon TS-LLD installation guide

JUMO ZELOS operating manual

JUMO

JUMO ZELOS operating manual

Imi Heimeier Wireless Air Sensor manual

Imi Heimeier

Imi Heimeier Wireless Air Sensor manual

Pima DPP310 instruction manual

Pima

Pima DPP310 instruction manual

Berkeley Varitronics Systems PocketHound user guide

Berkeley Varitronics Systems

Berkeley Varitronics Systems PocketHound user guide

ARVA NEO quick start guide

ARVA

ARVA NEO quick start guide

ADEMCO 1875EX installation instructions

ADEMCO

ADEMCO 1875EX installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.