SETUP:
There are only 2 option jumpers on the 4I64, W4 and W5.
These select the PC/104-PLUS "SLOT" number that the 4I64
occupies.
W4 W5 PC/104-PLUS SLOT
DOWN DOWN 0
DOWN UP 1
UP DOWN 2
UP UP 3 (Only newer CPUs support slot 3)
The 4I64 has a local power regulator (U4) for the Mini-PCI
cards 3.3V power. Maximumcurrent suppliedbythe regulator is 1A.
The 4I64 has 2 status LEDS and a connector (P1) to allow remote
LEDS to be connected. P1 is a 10 pin 2mm connector. P1 pin-out is
as follows:
PIN
1 Green+
2 Green-
3 Yellow+
4 Yellow-
5 NC
6 NC
7 NC
8 NC
9 GND
10 3.3V
External LEDS connected to P1 must have series current limiting
resistors.