MESTIC RTA-2500 User manual

MESTIC RTA-2500
AIRCONDITIONER
Owner’s Manual
Original Instructions
Recreational Vehicle Air Conditioner

23
A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 8
ELECTRICAL DATA 8
ELECTRIC DIAGRAM 9
PACKING LIST 10
PARTS NAME 11
OPERATION OF WIRELESS REMOTE CONTROLLER 12
CONTROL PANEL 19
INSTALLATION INSTRUCTION 20
STEP 1-SELECTING AN INSTALLATION LOCATION & INSTALLING THE
ROOF TOP AIR CONDITIONER 20
STEP 2-MOUNTING OUTDOOR UNIT 23
STEP 3-INSTALLING THE CEILING ASSEMBLY 24
STEP 4-ELECTRICAL WIRING 26
STEP 5-COMPLETING THE INSTALLATION 28
TROUBLESHOOTING GUIDE 29
ERROR CODE 30
NORMAL MAINTENANCE PROCEDURES 31

45
WAARSCHUWING:
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure
that they do not play with the appliance.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory
or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance.
• Cleaning and user maintenance shall not be made by children without supervision.
• To be in compliance with IEC/EN 61000-3-11, impedance value of power-supply system connected to product
must be less than or equal to the allowable maximum value of Zsys in the following sheet:
Model Max unit
RTA-2500 0.316 Ω

67
Requirements Forelectric Connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit.
3. For appliances with type Y attachment,the instructions shall contain the substance of the following.If the supply
cord is damaged,it must be replaced by the manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.Schakel de stroom
niet in voordat u klaar bent met de installatie.
6. Do not put through the power before finishing installation.
7. the air conditioner is first class electric appliance. It must be properly grounding. With specialized grounding
device by a professional. Please make sure it is
8. The yellow-green wire or green wire in air conditioner is grounding wire, which can’t be used for other purposes.
9. The grounding resistance should comply with national electric safety regulations.
10. The appliance shall be installed in accordance with national wiring regulations.
INSTALLATION PRECAUTION
WARNING:
• Observe all governing codes and ordinances.
• Do not use damaged or non-standard power cord.
• Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty
and other accidents.
• Before turning on the unit, please open the horizontal louver of indoor unit by hand, Otherwise, the cool air can’t
be blown out and there will be condensate water on the horizontal louver.
Working temperature range
Suggested working temperature range: +4 ~ 46°C . (heating:+4~24°C/cooling:+18~46 °C ). Outdoor unit may stop
operation. Due to various kinds of protection within working temperature range.
Selection of Installation Location
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult the local dealer:
1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4. The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. The place with sulfureted gas.
7. This air conditioner unit is only used for the vehicle without concave and convex surface on the top of it.
8. Prohibit operating this air conditioner unit when starting up the vehicle or when the vehicle is driving.
9. Prohibit supplying the power for the air conditioner unit with the vehicle power supply.
Requirement of air conditioner
1. Air inlet should be far away from obstacles and do not put any objects near air outlet. Otherwise, it will affect the
radiation of heat-removal pipe.
2. Select a location where the noise and outflow air emitted by the outdoor unit will not affect neighborood.
3. Please try your best to keep far away from fluorescent lamp.
4. The appliance shall not be installed in the laundry.
INSTALLATION PRECAUTION

89
ELECTRIC DIAGRAM
Thank you for choosing the Recreational Vehicle Air Conditioner. This manual will supply you with all the information
for installation, operation and maintenance. Take a few minutes to discover how to get the most in cooling comfort
and economic operation from your new air conditioner. Please keep this manual well for future reference. An all-pole
disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring.
ELECTRICAL DATA
1. All wiring must be complied with local and national electrical codes. All wiring must be installed by qualified
electricians. If you have any questions about the following instructions, contact a qualified electrician.
2. Check the available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3. This air conditioner is designed to operate from a 220-240V AC, 50Hz, 1 Phase power supply.
4. The wiring diagrams are located on the cover of the control box. The assembly unit wire diagrams are located on
the ceiling panel.
5. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
6. The Electric schematic diagram are subject to change without notice. Please refer to which one on the unit.
A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT

10 11
PARTS NAME
Packing List of Indoor Unit
Packing List of Outdoor Unit
PACKING LIST

12 13
Note:
• This is a general use remote controlle , it could be used for the air conditioners with multifunction; For some
function, which the model doesn’t have, if press the corresponding button on the remote controller that the unit
will keep the original running status.
• After putting through pow r, air conditioner will give out a sound and operation indicator “ “ is ON (red indicator).
You can operate the air conditioner through the remote controller.
• At ON status, after each pressing button on remote controller, the signal icon on remote controller will flash
once.Air conditioner will give out a sound,which indicates the signal has been sent to air conditioner.
• Under ff status, set temperature and clock icon will be displayed on the display of remote controller (If timer on,
timer off and light functions are set, the corre-sponding icons will be displayed on the display of remote controller
at the same time); Under on status, the display will show the corresponding set function icons.
1 ON/OFF button
Press this button, the unit will be turned on, press it once more, the unit will be turned off. When turning on or turning
off the unit, the Timer, Sleep function will be canceled, but the presetting time is still remained.
2MODE button
Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto mode is default while power on.
Under Auto mode, the temperature will not be displayed; Under Heat mode, the initial value is 28°C(82°F); Under
other modes, the initial value is 25°C(77°F).
(Only for cooling and heating unit. As for cooling only unit, it won’t have any action when it receives the signal of
heating operation.)
3 - button
Presetting temperature can be decreased. Press this button, the temperature can be set up, continuously press this
button and hold for two seconds, the relative contents can quickly change, until unhold this button and send the
order that the°C(°F) signal will be displayed all the time. The temperature adjustment is unavailable under the Auto
mode, but the order can be sent by if pressing this button.
4 + button
For presetting temperature increasing. Press this button, can set up the temperature, when unit is on. Continuously
press and hold this button for more than 2 seconds, the corresponding contents will be changed rapidly, until unpress
the button then send the information, °C(°F) is displlaying all along. In Auto mode, the temperature can not be set
up, but operate this button can send the signal. Centigrade setting range: 16-30; Fahrenheit scale setting range 61-
86.
INTRODUCTION FOR BUTTONS ON REMOTE CONTROLLER
Buttons on remote controller
Note: This remote controller is the universal remote controller. Some function is not available for this unit.
Introduction for icons on display screen
OPERATION OF WIRELESS REMOTE CONTROLLER
ON/OFF-button
MODE button
- button
+ button
FAN button
button
CLOCK button
LED button
TIMER ON button
TEMP button
TIMER OFF button
TURBO button
SLEEP button
LIGHT button

14 15
5 FAN button
Press this button, Auto, Low, Middle, High speed can be circularly selected. After powered on, Auto fan is not available
for this mode. When pressing AUTO button, the fan speed
will not change.
Note: Under the Dry mode, the fan speed isn’t adjustable, low fan speed is imperative, but when operating this
button, the wireless adjustable, low fan speed is imperative.
6 button
Press this button turn on swing function; 4s later, press this button to turn off the swing and it will operate like that
circularly. Other air conditioners, press this button, to set up swing angle, which circularly changes as below:
This is an universal use remote controller. If remote controller sends the following three kinds of status that the swing
status of main unit will be:
When the guide louver start to swing up and down, if turn off the Swing, the air guide louver will stop at current
position. which indicates the guide louver swings up and down between that all five positions.
7 CLOCK button
Press this button, the clock can be set up, signal blink and display. Within 5 seconds, the value can be adjusted by
pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten
place of Minute will be increased 1. During blinking, repress the Clock button, signal will be constantly displayed
and denotes the setting succeeded. After powered on,12:00 is defaulted to display and signal will be displayed. If
there is signal be displayed that denotes the current time value is Clock value, otherwise is Timer value.
8 LED button
Press this button can turn on or turn off the LED light on the panel.
9 TIMER ON button
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the
timer on setting status. During 5 seconds blink, by pressing + or - button to adjust the time value of numerical section,
every press of that button, the value will be increased or decreased 1 minute. Hold pressing + or - button, 2 seconds
later, it quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change in the one place of
minute, then the one place is constant, ten numbers change in the tens place of minute at 2.5 seconds speed and carry.
During 5s blink, press the Timer button, the timer setting succeeds. The Timer On has been set up, repress the timer
On button, the Timer On will be canceled. Before setting the Timer, please adjust the Clock to the current actual time.
10 TEMP-knop
Press this button, could select displaying the indoor setting temperature or indoor ambient temperature. When the
indoor unit firstly power on it will display the setting temperature, if the temperature’s displaying status is changed
from other status to “ “, displays the ambient temperature, 5s later or within 5s, it receives other remote control
signal that will return to display the setting temperature. if the users haven’t set up the temperature displaying status,
that will display the setting temperature. (This function is applicable to partial of models)
After powered on, the setting temperature displaying is defaulted, (according to cust- omers requirements to display,
if there is no requirement that will default to display the presetting temperature and there is no icon displayed on
wireless remote control). Press this button, (When displaying ), will display presetting temperature; (when
displaying ) will display indoor ambient temperature, current displaying status will not be changed. If current
displays indoor ambient temperature, if received the other remote control signal, it will display presetting temperatu-
re, 5s later, will back to display the ambient temperature.
(This function is applicable to partial of models)
11 TIMER OFF button
Once press this key to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink.
The method of setting is the same as for TIMER ON.
12 TURBO button
In Cool or Heat mode, press this button can turn on or turn off the Turbo function. After turned on the Turbo function,
its signal will be displayed. When switching the mode or changing fan speed, this function will be canceled automa-
tically.
13 SLEEP button
Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep Off is defaulted. After the unit is
turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display.In this mode, the
time of timer can be adjusted. Under Fan and Auto modes, this function is not available.
14 LIGHT button
Press this button to select LIGHT on or off in the displayer. When the LIGHT on is set, the icon will be displayed
and the indicator light in the displayer will be on. When the LIGHT off is set, the icon will be displayed and the
indicator light in the displayer will be off.

16 17
General operation
1. After powered on, press ON/OFF button, the unit wi start to run. (Note: when it is powered on, the guide louver
of main unit will close automatically.)
2. Press MODE button, select desired running mod
3. Pressing + or - button,to set the desired temperatur (It isunnecessary to set the temp. at AUTO mode.)
4. Pressing FAN button, set fan speed, can sele LOW, MID and HIGH.
5. Pressing button, to select the swin
Optional operation
1. Press SLEEP button, to set slee
2. Press TIMER ON and TIMER OFF button, can set the scheduled timer on or timer off.
3. Press LIGHT button, to control the on and off of t displaying part of the unit (This function may be not available
for some units).
4. Press TURBO button, can realize the ON and O of TURBO function.
5. Press LED button,can turn on or turn off the light the panel.
OPERATION GUIDE
About AUTO RUN
When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in ac-
cordance with the room temp. automatically to select the suitable running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temp. ap-
proachs the preset temp. as soon as possible.
About Blow over heat
(This function is applicable to partial of models)
When the unit is running in Heat mode or Auto Heat mode, compressor and indoor fan is running, to turn the unit off,
the compressor, outdoor fan will stop running. The upper and lower guide board rotate to horizontal position, then the
indoor fan will run at low fan speed, 10s later, the unit will turn off.
WIFI Function
Press “MODE” and “TURBO” button simultaneously to turn on or turn off WIFI function. When WIFI function is turned
on, the “WIFI“ icon will be displayed on remote controller; Long press “MODE” and “TURBO” buttons simultaneously
for 10s, remote controller will send WIFI reset code and then the WIFI function will be turned on. WIFI function is de-
faulted ON after energization of the remote controller. (This function only applicable for some models. )
INTRODUCTION FOR SPECIAL FUNCTION

18 19
CONTROL PANELREPLACEMENT OF BATTERIES IN REMOTE CONTROLLER
1. Press the back side of remote controller marked with “ “, as shown
in the fig, and then push out the cover of battery box along the arrow
direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position
of “+” polar and “-” polar are correct.
3. Reinstall the cover of battery box.
• During operation, point the remote control signal sender at the receiving window on indoor unit..
• The distance between signal sender and receiving window should be no more than 8m, and there should be
no obstacles between them.
• Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote
controller should be close to indoor unit during operation.
• Replace new batteries of the same model when replacement is required.
• When you don’t use remote controller for a long time, please take out the batteries.
• If the display on remote controller is fuzzy or there’s no display, please replace batteries.
NOTICE
Note: If the remote controller is missing, operate on the control panel.
1. ON/OFF button
Operation starts when pressing this button, and stops when pressing this button again.
2. LIGHT button
Press this button to turn on or turn off display light on indoor unit.
3. (+/-) button
Press the + button to increase the set(operating) temperature of the unit,and press the - button to decrease the
set(operating) temperature of the unit. the temperature setting range is from 16~30°C (61~86 oF).
4. FAN SPEED button
Select the fan speed LOW, MED, HIGH and TURBO in sequence.
5. MODE button
Select the operation mode, COOL,FAN, HEAT.
6. FILTER CHECK indicator
This feature is a reminder of cleaning the air filter(normal maintenance) for more efficient operation. The light will
turn on automatically after the fan works more than 250 hours. If the light is on, turn off and power off the unit,
take the air filter out and clean it, then re-install the air filter, power on and turn on the unit, the light will still be
on, press + button for 5s,the light will turn off.

20 21
INSTALLATION INSTRUCTION
BEFORE INSTALLATION
Testrun the unit with proper power supply. Refer to the operation instruction section in the Owner’s Manual Operation
& Installation. Make sure all the controls operate correctly then disconnect the power supply of the unit.
• Before installation, please check whether the unit is assembled with three pieces of rubber pads and square sealing
strip.
STEP 1-SELECTING AN INSTALLATION LOCATION & INSTALLING THE ROOF TOP AIR
CONDITIONER
Your air conditioner has been designed for use in recreational vehicles. Check the roof of the vehicle to determine
if it can support both the roof top unit and the ceiling assembly without additional support. Make sure the interior
ceiling mounting area will not interfere with existing structures. Once the location for your air conditioner has been
determined. A reinforced and framed roof hole opening must be cut (if there is no hole) or you may use existing vent
holes.
CASE A.
If a roof vent is already present in the desired mounting location for the air conditioner, the following steps must be
performed:
1. Remove all screws which secure the roof vent to the vehicle. Remove the vent and any additional trim. Carefully
remove all chalking from around the opening so the surface is clear.
2. It may be necessary to seal some of the old roof vent mounting screw holes which may fall outside of the air
conditioner basepan gasket.
3. Examine the roof opening size, if the opening is small than 356x356mm, the opening must be enlarged. If the
opening exceeds 356x356mm, a mounting plate (frame) must be fabricated to reduce the opening size (See
Figure 1).
• Moving parts may cause personal injury. Be careful when test the unit. Do not operate the unit with exterior
cover removed.
WARNING
1. It must be capable of supporting both the weight of
the roof top air conditioner and the interior ceiling
assembly.
2. It must be capable of holding the roof outer surface
and interior ceiling apart and supporting them, so
that when the roof top air conditioner and ceiling
assembly are bolted together,no collapsing occurs.
A typical support frame is shown in Figure 1.
3. There must be an opening through the frame for the
power supply wiring.Route the supply wiring through
the frame at the same time the support frame is
being installed.
CASE B.
Als er geen opening voor een dakventilatie aanwezig is, moet een nieuwe opening in het dak van het voertuig worden
uitgesneden. Er moet ook een bijpassende opening in het plafond binnen in het voertuig worden uitgesneden. Wees
voorzichtig, want het dakstuk kan vast komen te zitten als het dak uit meerdere lagen bestaat. Nadat de opening in het
dak en het plafond binnenin de juiste afmetingen hebben, moet een ondersteuning worden aangebracht tussen het
buitendak en het plafond binnen. Het versterkte raamwerk moet voldoen aan de volgende richtlijnen:
CAUTION
1. The roof top air conditioner must be mounted on a level plane from front to rear and side to side when the
vehicle is parked on a level plane. Figure 2 shows maximum allowable degrees that the unit can be mounted
above or below level.
2. If the roof of the vehicle is sloped (not level) such that the roof top air conditioner cannot be mounted within the
maximum allowable degree specifications, an exterior leveling shim will need to be added to make the unit level.
A typical leveling shim is shown in Figure 3.
3. Once the roof top air conditioner has been leveled, some additional shimming may be required above the
interior ceiling assembly. The roof top air conditioner and the interior ceiling assembly must be square with
each other before they are secured together.
4. After the mounting hole area is properly prepared, remove the carton and shipping pads from around the roof
top air conditioner. Carefully lift the unit on top of the vehicle. Do not use the outer plastic shroud for lifting.
Place the roof top air conditioner over the prepared mounting hole.
5. The point end (nose) of the shroud must face toward the front of the vehicle.

22 23
NOTE AIR CONDITIONER DIMENSIONS (ROOF OF UNIT)
STEP 2-MOUNTING OUTDOOR UNIT
1. Open the package and take out the outdoor unit 1)
When taking out the outdoor unit after unpacking,
do not lift the air outlet grille at the back of outer
case (see Figure4-1).
2. Fix the outdoor unit at the roof of vehicle and then
drill holes. 1) Place the outdoor unit at the roof of
vehicle; lift the outdoor unit and then place the
outdoor unit after drilling holes at the roof of vehicle.
Do not drag the outdoor unit. Otherwise, the sealing
strip may fall off (see Figure4-2).

24 25
STEP 3-INSTALLING THE CEILING ASSEMBLY
Make sure that you have properly matched the roof top air conditioner and interior ceiling assembly.Caution
before tightening bolts:
1. The applicable thickness of vehicle roof ranges from 30mm~80mm.
2. Before tightening bolts, screw in the four bolts manually and prohibit screwing forcibly.
3. When screwing bolts, you can use automatic tool. Do not tighten one bolt completely and then tighten other
bolts, in order to prevent sticking of screw thread.
4. The max torque for tightening ranges from 2.3Nm~2.5Nm.
NOTICE 1. Carefully take the ceiling assembly out of the carton
(The remote control packed with the ceiling assembly).
2. Remove the ceiling grille from the ceiling assembly.
3. Before installing the outdoor unit of recre- ational
vehicle air conditioner on the vehicle’s top,
preinstall the plate of air vent and foam (upper) on
the chassis of the outdoor unit with 4pc of screws
(25mm long) (See fig.5-1) .
4. Then carry the outdoor unit to the vehicle’s top
and align with the openings on the vehicle’s top.
Use 2 sets of mounting plate assembly and 4
screw bolts to mount the outdoor unit (See fig. 5).
You must start (thread) themounting bolts by hand
to avoid cross-threading. DO NOT START THE
MOUNTINGBOLTSWITHANAIRGUN.Themounting
bolts should be tightened, process is completed when
the basepan gasket has been evenly compressed.
5. Before installing the air duct assembly of the
indoor unit of recreational vehicle air conditioner,
assemble the foam assembly according to the
thickness of the vehicle’s top. After simulated
installation, use an appropriate amount of
sponge and foam assembly. Stick the sponge
and foam assembly with double faced adhesive
tape (prepared by user) (See fig.5-2, 5-3)..
6. Install the foam assembly on the air duct assembly.
Use 4 screw bolts to fix the air duct assembly onto
the mounting plate. After connecting the outdoor
unit with indoor unit, check whether the foam
assembly has come loose (See fig.5).
The following step by step instructions must be performed in the following sequence to ensure proper installation.

26 27
STEP 4-ELECTRICAL WIRING
ROUTING 220-240V AC WIRING
WARNING : Make sure that all power supply to the unit is disconnected before performing any work on the unit to avoid
the possibility of shock or injury and/or damage to the equipment. After the interior ceiling assembly frame is properly
secured to the roof top air conditioner, the following electrical connections must be performed.
ELECTRICAL WIRING
1. As shown in fig.7, the outdoor unit has two sets of
outgoing wires, which are power cord (high current)
and the control signal wires respectively. The former
one should be directly connected to the power supply
terminal while the latter one should be connected
to the control signal wire of the indoor unit.
2. As shown in fig.8, the indoor unit has one set of
control signal wires, with 4 wiring terminals in total.
3. As shown in the picture, connect the wiring terminals
of indoor and outdoor units one by one. Then use
a piece of sponge to wrap the wiring terminals
together, with each terminal separately encircled by
the sponge. Avoid gaps between each wire.
4 shown in the picture, use a piece of thermal insulating jacket to enclose the wiring terminals and sponge.
Then glue the thermal insulating jacket and fasten it with cable ties.
1. Cable ties must be attached to the area with both sponge and thermal insulating jacket;
2. Before installing the front panel of indoor unit, put the thermal insulating jacket on top of the air duct.
NOTE

28 29
STEP 5-COMPLETING THE INSTALLATION
To complete the installation and system checkout requirements, the following
steps must be performed.
1. Check the thermostat position. Make sure the thermostat is routed
through the holding guide and is not touching any metal surface.
2. Secure the ceiling grille to the ceiling assembly wind-path with 4
screws. (see Figure 10).
3. Install the healthy filter and air intake grill. Press “PUSH” and lock
with clasps.
4. Switch on the power supply and check the unit work or not.
5. Once the indoor unit is assembled, if the gap between the panel
and the top of vehicle is not even, please ask the manufacturer to
adjust it according to the assembly status.
TROUBLESHOOTING GUIDE
If you have problems with your recreational vehicle air conditioner, check this guide before contacting your service
representative.
COMPLETING THE INSTALLATION TROUBLESHOOTING

30 31
When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error
code. Please refer to below list foor indenrification of error code.
NORMAL MAINTENANCE PROCEDURES
ERROR CODE
Above indicator diagram is only
for reference. Please refer to actual
product for the actual indicator and
position.
HOW TO REMOVE THE AIR FILTER
Push both sides of the air intake grill on the positions
marked with “PUSH”. Open the air intake grill and then take out the healthy filter.
HOW TO CLEAN THE AIR FILTER
Wash away dust from the air filters with clean water or vacuum the filter with an electric household vacuum cleaner.
HOW TO DISMANTLE CLASP
Concrete dismantle method: use the similar tool in Figure b, align the clasp core and insert it, as Figure a is shown. The
inserted depth is about 3mm, as shown in Figure c, which the clasp is detachable. When you hear a sound, buckle the
clasp base with your hands to take out the clasp.
Note: If you insert it too deep, the clasp might be blocked, compulsory dismantle will damage the clasp and it might
be invalid. At this moment, use the tool whose diameter is smaller than the clasp to completely insert the core axis to
separate the clasp base and core axis, then it is dismantled.
Note: If there’re other error codes, please contact qualified professionals for service.

32
FAILURE TO FOLLOWING INSTRUCTIONS COULD RESULT IN SERIOUS PERSONAL INJURY
1. Don’t touch the capacitor terminals without the electric discharge, the capacitor still may have the
high voltage even though the power supply is turned off.
2. Be careful when you maintain the refrigeration system, which has the high internal pressure.
3. Do not block the filter and the indoor air inlet badly to prevent water leakage.
WARNING
Other manuals for RTA-2500
1
Table of contents
Other MESTIC Air Conditioner manuals