manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Metra Electronics
  6. •
  7. Repeater
  8. •
  9. Metra Electronics CS-IRKITCCUS User manual

Metra Electronics CS-IRKITCCUS User manual

CS-IRKITCCUS
460
Walker Street
Holly Hill, FL 32117-2699
[email protected]
www.MetraHomeTheater.com
1-866-839-9187 I386-257-1186
Melra
.....
t..........-
H □
ME
THEATER
GROUP
INFRARED
REPEATER
SYSTEM
User
Manual
~
HOME
SUPPORT
t:::J
866-839-9187
Thank
you
for
selecting
the
Metra
Home
Theater
CS-IRKITCCUS
to
be
apart ofyour entrainment
system.
With
it
you
can
extend
the
IR
(infrared)
signals
ofyour
remote
control
and
also
provide
an
interface to
relay
controlled
devices
(such
as
our
HDM-AIO,
Motorized
TV
lifts,
Screens
and
Drapery
systems).
Do
not install
in
wet locations,
do
not
open
chassis,
do
not
use
a
power supply other than the
one
included,
and
please
READ
THE
DIRECTIONS
CAREFULLY.
1.
Package
contents
12
Volt,
200
mA
Power
Supply
(1
each)
Single
Emitter
(4
each)
IR
Dual
Band
IR
Receiver
(1
each)
IR
Connecting
Block
with
Relay
Interface
(1
each)
Installation
Manual
(1
each,
currently
in
your
hands)
2.
Installation of
IR
control
components
Install the connecting block
in
an
accessible
location behind or
next to the controlled products
and
near
an
11
OV
plug.
Take
into
account the
IR
emitters
cable's
length
and
make
sure
that
all
cables
are
serviceable
and
kept
accessible
.
Mount the
IR
emitters onto the
IR
receiving port
on
each
ofthe
controlled
items.
Route
the emitter
cables
to the
IR
connecting block. A
self-adhesive
backing
is
supplied for
each
emitter.
NOTE:
Test
the
IR
emitter at the desired location prior the
removing
adhesive
backing.
Plug
the male emitter terminal into
the emitter ports
on
the connecting block.Mount the
IR
receiver
at
alocation that
can
easily
be
seen
by
your
hand
held remote.
NOTE:
Avoid
the
IR
receiver
being
placed
where it
is
exposed
to
direct sunlight or fluorescent light
as
these will overload
its
receiving capability. Experiment with the
best
location prior the
removing
adhesive
backing
.
Connect the power
supply.
You
are
now done with the
IR
section
of
your installation.
3.
Overview
of
the
Remote
learning
and
Relay
control
functions
The
CS-IRKITCCUS
is
very
unique
in
that it
has
the abilityto
learn
two
IR
codes
from most
remotes
to provide a
Dry
Contact
Closure
interface to
relay
controlled
devices
.
The
unit
also
comes
equipped with five
LED
indicators to show learning
plus
operating
status
and
two buttons to enable the
IR
code
learning
process.
1-
LED
Power
Indicator
2- BContact
Closed
(A
Open)
Indicator
3- AContact
Closed
(B
Open)
Indicator
4
-A
Closed
Learning
Indicator
5- B
Closed
Learning
Indicator
6- AContact
Close
Learn
7- BContact
Close
Learn
0
0
The
CS-IRKITCCUS
is
equipped with a4
Port
Phoenix
style
connecting terminal to allow the wiring ofyour
relay
controlled
devices
.
NA
-
No
purpose
(do
not
use)
A
Close
-
You
will
use
this portfor
one
conductor most
NC
(normally
closed)
products.-
When
A
is
closed
Bis open.
B
Close
-
You
will
use
this portfor
one
conductor most
NO
(normally open) products.
When
Bis
closed
A
is
open
Common -
This
port
is
used
for the
second
conductor for
any
NC
or
NO
device
.
NOTE:
THIS
IS
A
CONTACT
CLOSURE
DEVICE;
DO
NOT
CONNECT
POWER
TO
THE
PHOENIX
PLUG.
4.
Wiring
and
Programming
for
one
Relay
(Dry
Contact
Closure)
controlled
devices.
This
CS-IRKITCCUS
enables
you
to
copy
38
KHz
remote
codes
into the
product.
Connect thetwo
wires
from the
relay
controlled
device
into Port Afor'A
CLOSE
- B
OPEN"
operation
of
the
CS-IRKITCCUS
and
the common port
on
the
Phoenix
connector.
Select
the remote
(and
its
mode)
that
you
will
be
learning the
codes
from.
Unplug the
IR
receiver
from the connecting block,
place
the
remotes
IR
in-line pointed at the
IR
receiver port
and
within 6
inches
of
the
IR
receiving port.
Press
and
hold the
"A
CLOSE
LEARN"
button
(6)
with
one
hand
and
then
press
and
hold the
Remote
button that
you
want to
learn
with the other
hand
for
at
least
2
seconds,
release
both buttons
at
the
same
time, the
code
should now
be
learned.
Follow the
same
directions using the
"B
CLOSE
LEARN"
button
(7)
to
perform the
"B
Close
Learn"
process
.
To
verify the
learned
functions,
reconnect
the
IR
receiver
intothe
connection
block,
point the
remote
that
you
will
be
using
at
it
and
try
the buttons. lfthe'A"code
has
been
correctly
learned
LED"3"will light
up,
"4"will
also
light
up
for ashort time
and
then turn
off.
Follow
the
same
directions to perform the
•s
Close•
verification.
0
.,
I~
[
•I
E:::::
It
,
..
··-
.
,,
..
·-
Miirr.r»-
..
0
5.
Wiring
and
Programming
for
two
Relay
(Dry
Contact
Closure)
controlled
devices.
This
CS-IRKITCCUS
enables
you
to
copy
38
KHz
remote
codes
intothe
product.
Connect
the two
wires
from
the
relay
controlled
device
into
Port
Afor
"A
CLOSE
- B
OPEN"
operation ofthe
CS-IRKITCCUS
and
the
common
port
on
the
Phoenix
connector.
Connect
the two
wires
from
the
relay
controlled
device
into
Port
Bfor
•s
CLOSE
- A
OPEN"
operation ofthe
CS-IRKITCCUS
and
the
common
port
on
the
Phoenix
connector.
(See
4.
For
the
code
learning
instructions)
6.
Connection
to
a
control
system
The
CS-IRKITCCUS
can
be
easily
connected
tothe emitterport
on
a
control
system
using
our
CS-IRCC
cable.
This
cable
has
a
3.5mm
mono
plug that
connects
toyour control
system
IR
port
and
a
3.5mm
stereo
plug
that
is
inserted
intothe
IR
Receiver
port
on
the
CS-IRKITCCUS
connecting
block.
7.
Technical
Specs
IR
Connecting
Block
Power:
IR
Receiver
Connection:
Dimension:
Weight:
IR
Receiver
Connection:
Receive
Frequency
range:
Transmit
Frequency
range:
Cable
Length:
Tip:
Ring:
Sleeve:
Dimension:
Weight:
IREmitter
Connection:
Tip:
Sleeve:
Cable
Length:
Relay
Current
Rating:
Type:
100-240VAC,
12VDC,
200mA
(supplied)
3.5mm
Stereo
Jack
3.2S"x
1.8S"x
1·
7.5oz
3.5mm
Stereo
Jack
38KHZ
-
58KHz
38KHz
-
56
KHz
9'10"
Signal
Ground
12VDC
2.7"
X
.46"
X
.48"
.7oz
3.5mm
Mono
Jack
Signal
Ground
9'10"
2A
Single
Pole,
Double
Throw
A,D7ra>;-
H
□
ME
THEATER
GROUP
460
Walker Street
Holly Hill, FL 32117-2699
[email protected]
www.MetraHomeTheater.com
l-866-839-9187 I386-257-1186
~
HOME SUPPORT
Ll=J
866•839-9187
IR KIT WITH IR CONTROLLED
CONTACT CLOSURE
IR KIT WITH IR CONTROLLED CONTACT CLOSURE
CS-IRKITCCUS
www.MetraHomeTheater.com
1-866-839-9187 | 386-257-1186
SALES 866-839-9187
• Integrated IR learning feature for easy setup
• 2A dry contact relay
• Discrete open & close commands
• Open & close LED indicators
• Works with major US IR repeating systems
• Receive frequency range: 38 KHz & 56KHz
• Transmit frequency range: 38 KHz & 56KHz
• 6 port IR connecting block
• 1x RC-MM protocol compatible bar receiver 3 meters (9.84ft)
• 4x IR emitters 3 meters (9.84ft)
• 12 volt power supply
© COPYRIGHT 2018 METRA ELECTRONICS CORPORATION
8/18
The new Metra Home Theater CS-IRKITCCUS is a unique product; it has all of the usual capabilities and functions that one would
expect from a “US 12 V IR standard” plus a built in “contact closure” relay with “IR Code Learning” for its Open and Close states.
This gives the CS-IRKITCCUS the ability to control a wide variety of products including TV Lifts, Projection Screens, Curtains and
the Ethereal HDM-AIO and HDM-VCT HDMI repair devices.

Popular Repeater manuals by other brands

ActionTec WEB7200 user manual

ActionTec

ActionTec WEB7200 user manual

Andover Controls InfiLink 200 installation guide

Andover Controls

Andover Controls InfiLink 200 installation guide

Sundance Spas EV3-X manual

Sundance Spas

Sundance Spas EV3-X manual

ADC ADCP-75-237 user manual

ADC

ADC ADCP-75-237 user manual

IKEA TRADFRI E1746 manual

IKEA

IKEA TRADFRI E1746 manual

STEYR HDEX0015M1 user manual

STEYR

STEYR HDEX0015M1 user manual

Tait TB9400 Installation and operation manual

Tait

Tait TB9400 Installation and operation manual

Entel RP510 user guide

Entel

Entel RP510 user guide

Ariston 3318237 Assembly and operation instructions

Ariston

Ariston 3318237 Assembly and operation instructions

Digitus DS-55901 user manual

Digitus

Digitus DS-55901 user manual

Nikrans NS-500GW installation guide

Nikrans

Nikrans NS-500GW installation guide

Ksenia duo Universal KSI2600000.310 installation manual

Ksenia

Ksenia duo Universal KSI2600000.310 installation manual

Klark Teknik DN9610 AES50 user manual

Klark Teknik

Klark Teknik DN9610 AES50 user manual

EnGenius EOR7550 quick start guide

EnGenius

EnGenius EOR7550 quick start guide

Amped Wireless SR600EX Setup manual

Amped Wireless

Amped Wireless SR600EX Setup manual

Eminent EM4595 Quick install

Eminent

Eminent EM4595 Quick install

Multitone EkoSecure ESREP Quick installation guide

Multitone

Multitone EkoSecure ESREP Quick installation guide

Stahl Ispac 9170 1 Series operating instructions

Stahl

Stahl Ispac 9170 1 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.