A. C - D = If greater than 1½" then your secondary filter needs to be
changed.
B. A - C = If greater than ¾" then your pre-filter needs to be changed.
C. B - A = If greater than 2" then your hepa filter needs to be changed.
The spare filters for your machine are: Part No.
Pre-Filter 23½" x 25½" x 9" cube FTB003
Secondary Filter 23½" x 23½" x 18" bag, 95% efficient FTB020
Hepa Filter 23½" x 23½" x 11½" Hepa FTH024
On the following page there is a wiring diagram that indicates how the
motor, controller and control panel are interfaced together. Do not attempt to
open the control panel or the controller unless you are qualified to do such work.
The following chart will outline the desired values for selected parameters
on the adjustable speed controller. The controller is programmed at the factory
so that these values remain constant. Parameters are not intended to be
changed other than through the control panel. Should you have any questions
about these or any other parameters, please consult the factory.
Parameter Name Setting
Acceleration 15 sec.
Deceleration 10 sec
Minimum frequency 20 Hz
Maximum frequency 75 Hz
Base frequency 60 Hz
If your vacuum shuts itself down, it is probably because you overloaded
the motors controller. Go to the back of the machine and push the stop button on
the controller. This will reset the controller. Before you start the machine again,
turn down the speed control to a low level and slowly turn it up as you start the
machine. Never run the vacuum in excess of 19 amps.
NOTE: All warranty repairs must go through Meyer Machine & Equipment, Inc.
prior to any service work being done. Work not authorized by Meyer Machine will
not be covered under warranty.