Area floodlight for metal halide (HIT-DE) or
high pressure sodium (HST-DE) lamps
250 Watts, lampholder Fc2.
MOUNTING INSTRUCTIONS
Light fitting is suitable for installation on
normal inflammable building materials.
Attention ! High Voltage !
Disconnect power supply before opening
light fitting or changing lamp.
Ensure that the correct size of pole is chosen;
if necessary consult the pole manufacturer.
Loosen screws in front frame. Lift frame and
glass and swing away from casing. Open
control gear cover. Depending on height of
pole, take a sufficiently long piece of cable
and insert it through the cable gland.
Strip the sheathing off the last 16 cm of cable
and slide the enclosed silicone sleeves over
the individual wires.
ATTENTION ! Do not insert more than 2 cm
of sheathed cable into luminaire housing:
Ensure that the wires do not make contact
with the control gear cover. Make the
electrical connection. Screw cable gland
tight. Close control gear cover.
Insert lamp, taking care to use the correct
lamp as mentioned on the rating plate.
If a high pressure sodium lamp is to be used,
make sure that only lamps bearing the -
sign are used.
Connect the light fitting in compliance with
prevailing regulations in your country.
Swing front frame and glass back onto casing
and screw down evenly. Hang the luminaire
onto the M10 x 40 screws on the pole top
fitter and tighten with 44 Nm torque.
The threaded inserts in the pole top fitter are
self locking. Push cable through hole in pole
and connect to connection box in base of
pole.
Mounting on pole top fitter
Luminaire for non-protected outdoor
installation.
Fluxa BA
Area floodlight
Protection IP 54
Safety Class I
8 275 1.5
8 276 1.5
t 25°C
a
Mouning on the Wall Plate
Mounting on other surfaces
Make sure that the wall plate is sufficiently
securely fixed to the installation surface.
Hang the luminaire onto the M10 x 40
screws and tighten them with a torque
of 44 Nm. The threaded inserts in the wall
plate are self locking. Insert the cable
through the cable gland into the luminaire
and then proceed with the electrical
connection as mentioned above.
Make sure that the installation surface is
sufficiently stable and strong. To attach the
luminaire, use at least 2 stainless steel
M10 x 40 screws of hardness 70.
Take adequate precautions to prevent the
screws from loosening. Make electrical
connection as mentioned above.
The glass is toughened safety glass.
Ensure that the minimum spacing between
luminaire and illuminated surface is
observed.
The light fitting may be operated only if all
protective covers are in place.
Type Weight Projected area
8 275 1.5 14 kg 0,19 m²
8 276 1.5 14 kg 0,19 m²
F
MOUNTING
INSTRUCTIONS
.
Stemmessiepener Weg 5 D-58675 Hemer
F
min 1,0 m