INFLATION OPERATION
1. From the white universal adaptor, select the reducer that engages and opens the
valve of the inatable structure.
2. Insert the selected adaptor on the braided joint on the end of the tube.
3. Tighten the black adaptor on to the ination side of the inator (OUT).
4. Check that both start switches are set to ( 0 ).
5. Insert the plug and set the orange switch to position ( | ). If necessary, also use the
red switch to obtain maximum performance to start the ination.
6. The inator is limited to a maximum pressure of 140 mbar (orange switch) and 350
mbar (orange+red switches).
7. When the maximum pressure is reached, switch o the inator immediately to avoid
overheating the motor.
DEFLATING OPERATION
1. From the white universal adaptor, select the reducer that engages and opens the
valve of the inatable structure.
2. Insert the selected adaptor on the braided joint on the end of the tube.
3. Fit the black adaptor on to the deation side of the inator (IN).
4. Check that both ON switches are set to ( 0 ).
5. Insert the plug and set the orange switch to position ( | ). If necessary, also use the
red switch to obtain maximum performance to start the deating.
6. When the inatable is completely deated, switch o the inator immediately to avoid
overheating the motor.
NOTE: It is advisable to check the pressure with a pressure gauge.